| Literature DB >> 28284003 |
Galina Khokhlova1, Mikhail Vainshtein2,3.
Abstract
The paper presents effects of different magnetic fields (MFs) (static-SMF and impulse-IMF) on bacteria Rhodospirillum rubrum VKM B-1621. The MFs had different magnetic strength: SMF-up to 173 mT; IMF-25 mT. The studied object was amylase activity which was measured by decrease in the starch concentration during incubation in the MFs. The term of incubation in the MFs was limited with 2 h. The SMF affected neither amylase activity of R. rubrum nor standard deviation in distribution of the residual starch concentration along the plate but the IMF did. The IMS effects varied along the plate which could be related with distance from the magnetic center of the applied device. In whole, application of impulse MFs can regulate bacterial activity and thus could be used for biotechnological application.Entities:
Keywords: Amylase activity; Magnetic fields; Rhodospirillum rubrum
Year: 2017 PMID: 28284003 PMCID: PMC5346098 DOI: 10.1186/s13568-017-0362-9
Source DB: PubMed Journal: AMB Express ISSN: 2191-0855 Impact factor: 3.298
Fig. 1Distribution of the static magnet field (SMF) in 96 wells of the plate. Axis Z strength of the SMF, mT; X rows of the wells, 1–12; Y columns of the wells, A–H
Statistics: residual concentrations of starch (measured by optical density after reaction with iodine) in the R. rubrum culture after 2 h exposition in the geomagnetic field (Blank) and in the impulse magnet field (IMF)
| Level of growth as starch concentration by OD, % of initial | 98 | 79 | 68 | 60 |
| Geomagnetic field (blank) | ||||
| Final starch concentration in the experiment, OD, average mean (x) | 3.26 | 2.63 | 2.24 | 1.98 |
| OD standard deviation (s) for 12 columns | 0.006 | 0.009 | 0.007 | 0.007 |
| Impulse magnet field (IMF) | ||||
| Final starch concentration in the experiment, OD, average mean (x) | 3.18 | 2.01 | 1.84 | 1.92 |
| OD standard deviation (s) for 12 columns | 0.021 | 0.200 | 0.050 | 0.037 |
Number of the data in each group was presented by 96 wells of plate (8 rows, 12 columns)
Statistics: residual concentrations of starch (measured by optical density after reaction with iodine) in the R. rubrum culture after 2 h exposition in the static magnet field (SMF)
| Nos. of the data groups | Ranges of the SMF, mT | Number of wells (number of the data in the group, n) | OD | |
|---|---|---|---|---|
| Average mean (x) | Sample variance (s2) | |||
| 1 | 0.0–0.5 | 18 | 3.01 | 0.285256 |
| 2 | 0.6–1.0 | 18 | 3.27 | 0.103128 |
| 3 | 1.1–3.0 | 18 | 3.25 | 0.252374 |
| 4 | 3.6–16.0 | 18 | 3.27 | 0.144751 |
| 5 | 16.0–85 | 18 | 3.22 | 0.165431 |
| 6 | 120–173 | 6 | 3.15 | 0.228619 |
|
| 0.182701 | |||
|
| 0.116315 | |||
| F = | 1.57075 | |||
| F0.95 | 2.315689 | |||
F < F0.95 thus, there is no difference between the groups of the data at the 95% level of degrees of freedom
Fig. 2Effects of the applied impulse magnetic field on amylase activity of R. rubrum presented as difference between residual starch concentrations in IMF and in geomagnetic field in wells along 12 columns (axis X) of the 96 well plate after exhibition, OD average (4 experiments × 8 rows for each column)