Literature DB >> 28283852

Short term general anesthesia for retro-bulbar block in ophthalmic surgery generates no significant hypercapnia.

Werner Baulig1, Monica Weber2, Beatrice Beck-Schimmer2, Oliver M Theusinger2, Peter Biro2.   

Abstract

To assess the impact of short time hypnosis for retro-bulbar anesthesia on ventilation in patients undergoing ophthalmic surgery of the anterior eye chamber. In all patients, a combined continuous transcutaneous carbon dioxide tension (PtcCO2) and partial oxygen saturation (SpO2) measurement was applied in addition to routine monitoring. To enable unconscious application of retro-bulbar anesthesia, intravenous thiopental was given in one to multiple bolus doses. Transient breathing support included chin lift, Esmarch maneuver and manual hand-bag ventilation via face mask. Main endpoints were apnea time, recovery time according to the Richmond Agitation Sedation Scale, as well as SpO2 and PtcCO2 readings at predefined time points. Fifty-two patients with a mean age of 68 ± 13 years were included. Average thiopental dose was 2.7 ± 0.6 mg/kg. In seven (13.5%) patients repeated doses of thiopental were necessary to a total of 3.3 ± 1.1 mg/kg. Except one patient, no severe, significant or clinical relevant hypercapnia or desaturation periods were observed, and the occurring elevation of PtcCO2 values did not correlate with the application of repeated doses of thiopental or the need for the Esmarch maneuver. Higher PtcCO2 values were associated with the presence of hypertension and smoking. Apnea (p < 0.001) and recovery (p = 0.003) time were significantly prolonged in the patients needing the Esmarch maneuver. Short term anesthesia with thiopental in ophthalmic surgery is associated with a mild but not clinically relevant hypercapnia.

Entities:  

Keywords:  Ophthalmic surgery; PtcCO2 monitoring; Thiopental anesthesia

Mesh:

Substances:

Year:  2017        PMID: 28283852     DOI: 10.1007/s10877-017-0011-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  31 in total

Review 1.  Complications of transradial catheterization.

Authors:  Vineet K Dandekar; Mladen I Vidovich; Adhir R Shroff
Journal:  Cardiovasc Revasc Med       Date:  2011-11-23

2.  Overnight variability in transcutaneous carbon dioxide predicts vascular impairment in women.

Authors:  Jenni Aittokallio; Olli Polo; Jukka Hiissa; Arho Virkki; Jyri Toikka; Olli Raitakari; Tarja Saaresranta; Tero Aittokallio
Journal:  Exp Physiol       Date:  2008-02-22       Impact factor: 2.969

3.  Effects of propofol, etomidate, and thiopental on intraocular pressure and hemodynamic responses in phacoemulsification by insertion of laryngeal mask airway.

Authors:  Mohammad Alipour; Akbar Derakhshan; Reza Pourmazar; Mojtaba Abrishami; Vahid Ghavami Ghanbarabadi
Journal:  J Ocul Pharmacol Ther       Date:  2014-07-03       Impact factor: 2.671

4.  Optimal target concentration of remifentanil during cataract surgery with monitored anesthesia care.

Authors:  Jung-Hee Ryu; Yun-mi So; Jung-Won Hwang; Sang-Hwan Do
Journal:  J Clin Anesth       Date:  2010-11       Impact factor: 9.452

5.  Accuracy of end-tidal carbon dioxide monitoring using the NBP-75 microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patients.

Authors:  A Casati; G Gallioli; M Scandroglio; R Passaretta; B Borghi; G Torri
Journal:  Eur J Anaesthesiol       Date:  2000-10       Impact factor: 4.330

6.  [Pharmacokinetics of intravenous non-steroidal anesthetics].

Authors:  J Kienlen; P Chardon
Journal:  Ann Anesthesiol Fr       Date:  1981

7.  Transcutaneous carbon dioxide monitoring in spontaneously breathing, nonintubated patients in the early postoperative period.

Authors:  G Fanelli; M Baciarello; G Squicciarini; G Malagutti; M Zasa; A Casati
Journal:  Minerva Anestesiol       Date:  2008 Jul-Aug       Impact factor: 3.051

8.  Transcutaneous carbon dioxide pressure monitoring in a specialized weaning unit.

Authors:  Douglas C Johnson; Salma Batool; Ronald Dalbec
Journal:  Respir Care       Date:  2008-08       Impact factor: 2.258

9.  A survey of transcutaneous blood gas monitoring among European neonatal intensive care units.

Authors:  Mario Rüdiger; Kerstin Töpfer; Hannes Hammer; Gerd Schmalisch; Roland R Wauer
Journal:  BMC Pediatr       Date:  2005-08-10       Impact factor: 2.125

Review 10.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.