Literature DB >> 28282673

Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison.

Eric R Vaillant1, Brent G Parks1, Lyn M Camire1, Richard Y Hinton1.   

Abstract

The aim of this article is to compare diameter and stiffness, displacement, and strain in a five-strand versus four-strand hamstring graft for anterior cruciate ligament reconstruction. Eight matched pairs of lower extremities underwent four-strand or five-strand hamstring graft reconstruction. Diameter was significantly higher in the five-strand versus the four-strand construct (p = 0.002). No significant difference was found between the groups in construct displacement or stiffness. Significantly higher strain was observed in the inner limb versus the outer limb in the four-strand construct (p = 0.001) and in the inner limb versus the fifth limb in the 5-strand construct (p = 0.004). A fifth limb added to a four-strand hamstring graft significantly increased graft diameter but did not significantly change stiffness or displacement, suggesting that attachment of additional graft material via suture did not provide for full incorporation of the added limb into the graft at time zero. The inner limb in both constructs absorbed significantly greater load than did other limbs. The use of suture to attach additional material to a four-strand hamstring graft may not contribute to improved biomechanical qualities of the graft at time zero. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Mesh:

Year:  2017        PMID: 28282673     DOI: 10.1055/s-0037-1599248

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  4 in total

1.  Anterior Cruciate Ligament Reconstruction with 4-Strand Hamstring Tendon Construct May be Biomechanically Superior to 5-Strand Hamstring Tendon Construct When Using Femoral Suspensory Fixation.

Authors:  Mia S Hagen; Woody Sorey; Ermyas Kahsai; Scott Telfer; Kenneth Chin; Christopher Y Kweon; Albert O Gee
Journal:  Arthrosc Sports Med Rehabil       Date:  2022-05-24

2.  [Analysis of influence factor for the failure of anterior cruciate ligament reconstruction].

Authors:  Jian Wang; Haijun Wang; Lin Lin; Jiakuo Yu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-12-15

Review 3.  Five-Strand Hamstring Autografts for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

Authors:  John-Rudolph H Smith; Darby A Houck; Jessica A Hart; Armando F Vidal; Rachel M Frank; Jonathan T Bravman; Eric C McCarty
Journal:  Orthop J Sports Med       Date:  2019-02-22

4.  A 5-Strand Hamstring Autograft Achieves Outcomes Comparable to Those of a 4-Strand Hamstring Autograft With a Graft Diameter of 8 mm or More in Anterior Cruciate Ligament Reconstruction.

Authors:  Lingaraj Krishna; Xin Yang Tan; Francis Keng Lin Wong; Shi Jie Toh
Journal:  Orthop J Sports Med       Date:  2018-03-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.