Literature DB >> 28280534

Biomechanical behaviour of a jawbone loaded with a prosthetic system supported by monophasic and biphasic implants.

F Inchingolo1, L Paracchini2, F DE Angelis3, A Cielo4, A Orefici4, D Spitaleri2, L Santacroce5, E Gheno2, A Palermo2.   

Abstract

Modern implantology is based on the use of endosseous dental implants and on the study of osseointegration processes. The loss of marginal bone around a dental implant can be caused by many factors; the proper distribution of the masticatory loads is important and is closely dependent on the quality and quantity of bone tissue surrounding the implant. In fact, bone has the ability to adapt its microstructure, through processes of resorption and neoformation of new bone matrix, as a result of the mechanical stimuli that are generated during the chewing cycles. The purpose of this article is to redefine in a modern key and in light of current industrial and engineering technology, clinical and biomechanical concepts that characterize the monophasic implants, in order to assess proper use by evaluating the biomechanical differences with the biphasic implants.

Keywords:  FEM analysis; biomechanics; biphasic implants; monophasic implants

Year:  2017        PMID: 28280534      PMCID: PMC5333746          DOI: 10.11138/orl/2016.9.1S.065

Source DB:  PubMed          Journal:  Oral Implantol (Rome)        ISSN: 1974-5648


  20 in total

1.  Piezosurgery vs High Speed Rotary Handpiece: a comparison between the two techniques in the impacted third molar surgery.

Authors:  F N Bartuli; F Luciani; F Caddeo; L DE Chiara; M DI Dio; P Piva; L Ottria; C Arcuri
Journal:  Oral Implantol (Rome)       Date:  2013-07-15

2.  Guided bone regeneration via a preformed titanium foil: clinical, histological and histomorphometric outcome of a case series.

Authors:  M Andreasi Bassi; C Andrisani; S Lico; Z Ormanier; L Ottria; M Gargari
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

Review 3.  Biomaterials and biomechanics in dental implant design.

Authors:  J B Brunski
Journal:  Int J Oral Maxillofac Implants       Date:  1988       Impact factor: 2.804

4.  3D finite element analysis to detect stress distribution: spiral family implants.

Authors:  Matteo Danza; Ilaria Zollino; Luigi Paracchini; Guidi Riccardo; Stefano Fanali; Francesco Carinci
Journal:  J Maxillofac Oral Surg       Date:  2010-04-24

5.  Regenerative surgery performed with platelet-rich plasma used in sinus lift elevation before dental implant surgery: an useful aid in healing and regeneration of bone tissue.

Authors:  F Inchingolo; M Tatullo; M Marrelli; A M Inchingolo; A D Inchingolo; G Dipalma; P Flace; F Girolamo; A Tarullo; L Laino; R Sabatini; A Abbinante; R Cagiano
Journal:  Eur Rev Med Pharmacol Sci       Date:  2012-09       Impact factor: 3.507

6.  Intra-osseous anchorage of dental prostheses. I. Experimental studies.

Authors:  P I Brånemark; R Adell; U Breine; B O Hansson; J Lindström; A Ohlsson
Journal:  Scand J Plast Reconstr Surg       Date:  1969

7.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw.

Authors:  R Adell; U Lekholm; B Rockler; P I Brånemark
Journal:  Int J Oral Surg       Date:  1981-12

8.  Development of patient-based questionnaire about aesthetic and functional differences between overdentures implant-supported and overdentures tooth-supported. Study of 43 patients with a follow up of 1 year.

Authors:  M Gargari; V Prete; M Pujia; F M Ceruso
Journal:  Oral Implantol (Rome)       Date:  2013-03-19

9.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981

10.  Three-point bending tests of zirconia core/veneer ceramics for dental restorations.

Authors:  Massimo Marrelli; Carmine Maletta; Francesco Inchingolo; Marco Alfano; Marco Tatullo
Journal:  Int J Dent       Date:  2013-02-25
View more
  1 in total

1.  A Three-Dimensional Finite Element Analysis of Aramany Class I Obturator Fabricated with Different Alloys.

Authors:  Kashinath C Arabbi; Takshil D Shah; Mahantesha Sharanappa; Shobha K Subbaiah
Journal:  J Pharm Bioallied Sci       Date:  2019-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.