Annemarie Berger1, Sabine Salla2, Oliver T Keppler3, Holger F Rabenau1. 1. Institute of Medical Virology, Hospital of the Goethe University of Frankfurt, Frankfurt/M., Germany. 2. Department of Ophthalmology, RWTH Aachen University, Germany. 3. Institute of Medical Virology, Hospital of the Goethe University of Frankfurt, Frankfurt/M., Germany; Max von Pettenkofer-Institute, Ludwig-Maximilians-University Munich, Munich, Germany.
Abstract
BACKGROUND: The HCV RNA testing of potential cornea donors frequently relies on blood samples stored pre mortem. The recommended storage time of maximum 72 h frequently excludes a significant fraction of donors. METHODS: The influence of storage time of EDTA plasma samples at 4 °C on the viral load measured with the Roche HCV Quantitative Test vs. 2.0 was evaluated for 43 samples from HCV-positive individuals. RESULTS: The mean reduction of the viral load after 4 °C storage for 6-8 days was 0.46 log10 IU/ml (range +0.17 to -1.66 log10 IU/ml). After 1-3 days a mean loss of 0.19 log10 IU/ml (range +0.30 to -1.41 log10 IU/ml) and after 3-5 days of 0.32 log10 IU/ml (range +0.36 to -1.81 log10 IU/ml) was observed. In 23.3% of samples, a viral load reduction ≥ 1 log10 IU/ml (1.0-1.81 log10 IU/ml) was found after prolonged storage (5-8 days). In none of the samples did the HCV load fall below the detection limit. CONCLUSION: Plasma storage for up to 8 days can quantitatively reduce the HCV RNA load, yet has no influence on the reliability of a qualitative HCV RNA detection by this ultrasensitive test to determine the HCV status of serologically negative cornea donors.
BACKGROUND: The HCV RNA testing of potential cornea donors frequently relies on blood samples stored pre mortem. The recommended storage time of maximum 72 h frequently excludes a significant fraction of donors. METHODS: The influence of storage time of EDTA plasma samples at 4 °C on the viral load measured with the Roche HCV Quantitative Test vs. 2.0 was evaluated for 43 samples from HCV-positive individuals. RESULTS: The mean reduction of the viral load after 4 °C storage for 6-8 days was 0.46 log10 IU/ml (range +0.17 to -1.66 log10 IU/ml). After 1-3 days a mean loss of 0.19 log10 IU/ml (range +0.30 to -1.41 log10 IU/ml) and after 3-5 days of 0.32 log10 IU/ml (range +0.36 to -1.81 log10 IU/ml) was observed. In 23.3% of samples, a viral load reduction ≥ 1 log10 IU/ml (1.0-1.81 log10 IU/ml) was found after prolonged storage (5-8 days). In none of the samples did the HCV load fall below the detection limit. CONCLUSION: Plasma storage for up to 8 days can quantitatively reduce the HCV RNA load, yet has no influence on the reliability of a qualitative HCV RNA detection by this ultrasensitive test to determine the HCV status of serologically negative cornea donors.
Entities:
Keywords:
Cornea donor testing; HCV-PCR; Prolonged sample storage at 4 °C
Authors: G Gessoni; P Barin; S Valverde; A Giacomini; C Di Natale; E Orlandini; N Arreghini; G De Fusco; A Frigato; M Fezzi; F Antico; G Marchiori Journal: Transfus Apher Sci Date: 2004-06 Impact factor: 1.764
Authors: G Gessoni; P Barin; A Frigato; M Fezzi; G de Fusco; N Arreghini; P Galli; G Marchiori Journal: J Viral Hepat Date: 2000-07 Impact factor: 3.728
Authors: Barna D Tugwell; Priti R Patel; Ian T Williams; Katrina Hedberg; Feng Chai; Omana V Nainan; Ann R Thomas; Judith E Woll; Beth P Bell; Paul R Cieslak Journal: Ann Intern Med Date: 2005-11-01 Impact factor: 25.391