Literature DB >> 22802139

Comparative infectious serology testing of pre- and post-mortem blood samples from cornea donors.

I Wilkemeyer1, A Pruss, U Kalus, J Schroeter.   

Abstract

Defined serological blood tests of deceased cornea donors are required to minimize the risk of viral infections of a transplant recipient as much as possible. Haemolysis, autolysis and bacterial contamination, may produce significant changes of post-mortem blood samples, which may lead to false serological test results. Pre- and post-mortem findings from the same cornea donors of the University Tissue Bank of the Charité in the years 2004-2009 (n = 487) were retrospectively analyzed and compared. The test results from pre-mortem blood samples were defined as the reference for the post-mortem blood test. Of 487 cornea donors, there were a total of 21 cases (4.3%) with discrepancies between serological test results from pre- and post-mortem blood samples. Of these, 7 values referred to the HBsAg-testing, 3 to the anti-HBs-, 1 to the anti-HBcIgG + IgM-, 1 to the anti-HCV-, 4 to the anti-HIV 1/2- and 5 to the TPLA-findings. False negative results within post-mortem serology occurred in 4 of 487 cases (0.8%). False positive results within the post-mortem blood samples occurred at a much more frequent rate, with 17 of 487 cases (3.5%). Discrepancies between serological pre- and post-mortem blood tests occur mainly due to the use of non-validated test systems. Therefore, it seems reasonable to test pre- and post-mortem blood samples serologically, whenever possible, at the same time, regardless of the sample age. Positive results, regardless of the sample type, should always be retested with validated confirmation tests (e.g. NAT), in order to differentiate between false and true positive results.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22802139     DOI: 10.1007/s10561-012-9326-0

Source DB:  PubMed          Journal:  Cell Tissue Bank        ISSN: 1389-9333            Impact factor:   1.522


  9 in total

1.  HCV RNA Testing of Plasma Samples from Cornea Donors: Suitability of Plasma Samples Stored at 4 °C for up to 8 Days.

Authors:  Annemarie Berger; Sabine Salla; Oliver T Keppler; Holger F Rabenau
Journal:  Transfus Med Hemother       Date:  2016-11-04       Impact factor: 3.747

Review 2.  Hepatitis B transmission by cell and tissue allografts: how safe is safe enough?

Authors:  Pilar Solves; Vicente Mirabet; Manuel Alvarez
Journal:  World J Gastroenterol       Date:  2014-06-21       Impact factor: 5.742

3.  Validation of Spiked Postmortem Blood Samples from Cornea Donors on the Abbott ARCHITECT and m2000 Systems for Viral Infections.

Authors:  Ingo Schmack; Seda Ballikaya; Brigitte Erber; Irina Voehringer; Ulrich Burkhardt; Gerd U Auffarth; Paul Schnitzler
Journal:  Transfus Med Hemother       Date:  2019-09-24       Impact factor: 3.747

4.  Keeping an eye on decellularized corneas: a review of methods, characterization and applications.

Authors:  Samantha L Wilson; Laura E Sidney; Siobhán E Dunphy; James B Rose; Andrew Hopkinson
Journal:  J Funct Biomater       Date:  2013-07-10

5.  Comparison of seropositivity of human immunodeficiency virus, hepatitis B virus, hepatitis C virus, and syphilis among Hospital Cornea Retrieval Programme-Donors versus voluntary cornea donors at a large eye bank in Eastern India.

Authors:  Soham Basak; Samar K Basak; Bani Biswas
Journal:  Indian J Ophthalmol       Date:  2017-11       Impact factor: 1.848

6.  How safe is safe, and where are we in the journey toward safest of safe?

Authors:  Lalit Dar; Radhika Tandon
Journal:  Indian J Ophthalmol       Date:  2017-11       Impact factor: 1.848

7.  Seroprevalence of Coxiella burnetii antibodies and chronic Q fever among post-mortal and living donors of tissues and cells from 2010 to 2015 in the Netherlands.

Authors:  Sonja E van Roeden; Eleonoor W Holsboer; Jan Jelrik Oosterheert; Jorge P van Kats; Jacqueline van Beckhoven; Boris M Hogema; Marja J van Wijk
Journal:  Euro Surveill       Date:  2018-03

8.  Prevalence of blood-borne viral infections among autopsy cases in Jordan.

Authors:  Faris G Bakri; Imad M Al-Abdallat; Nidaa Ababneh; Rayyan Al Ali; Ahmed K F Idhair; Azmi Mahafzah
Journal:  Qatar Med J       Date:  2017-04-21

9.  Factors influencing the virological testing of cornea donors.

Authors:  Tobias Röck; Robert Beck; Stefan Jürgens; Karl Ulrich Bartz-Schmidt; Matthias Bramkamp; Sebastian Thaler; Daniel Röck
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.