| Literature DB >> 28274907 |
Jing Zhang1, Lei Sun1, Yu Liu2, Hongyi Wang3, Ningling Sun3, Puhong Zhang1.
Abstract
BACKGROUND: Electronic data capture (EDC) systems have been widely used in clinical research, but mobile device-based electronic data capture (mEDC) system has not been well evaluated.Entities:
Keywords: clinical research; electronic data capture; mEDC; mhealth; mobile data capture; randomized controlled trial
Mesh:
Substances:
Year: 2017 PMID: 28274907 PMCID: PMC5362692 DOI: 10.2196/jmir.6978
Source DB: PubMed Journal: J Med Internet Res ISSN: 1438-8871 Impact factor: 5.428
Functions and features of mobile device–based electronic data capture (mEDC) and relevant requirements as per electronic data capture (EDC) guidelines.
| No. | Functions and features of mEDCa,b | Requirements per EDCa,c guidelines and comments | |
| 1 | |||
| Logistic management | Should be maintained either onsite or be remotely accessible through electronic files (IV-B: SOPd [ | ||
| Role allocation | Access must be limited to authorized individuals (IV-D-1: Limited access [ | ||
| 2 | |||
| Screening | These 6 parts follow “Guidance for Industry Computerized Systems Used in Clinical Investigations” [ | ||
| Data collection at baseline | |||
| Centralized randomization | |||
| Data collection during follow-up | |||
| BPe measurement | |||
| Record of adverse events | |||
| 3 | |||
| Biological sample collection | The same as No. 2 (same as above) | ||
| Medicine prescription | |||
| 4 | To assure that data are reliable, complete, and accurate (Data entry and data processing [ | ||
| 5 | A copy of the data should be maintained at another location, typically at the clinical site (IV-C: Source documentation and records retention [ | ||
| 6 | |||
| Clicking a photograph of informed consent forms to ensure completion of IRBg operations | No requirements for IRB operations in the guidelines | ||
| 7 | |||
| Quality control for BP measurements | No requirements for quality control of BP measurements in the guidelines | ||
| Quality control for consistence of medicine codes | Ensuring processes are defined to integrate laboratory and other non-CFRh data with the data from the eCRFi (Electronic Data Capture Principles [ | ||
| Project progress and status reports | Automate generation of reports on metrics and project status to facilitate project or site or patient management (Electronic Data Capture Principles [ | ||
aMobile phone Redmi Note (5.5 inch, 1GB RAM, 32GB ROM, 4G Dual SIM, Android system v4.2) was used as the mobile device. Moreover, mEDC can be installed and used in mobile phones from most other brands that are based on the Android system.
bmEDC: mobile device-based electronic data capture.
cEDC: electronic data capture.
dSOP: standard operating procedure.
eBP: blood pressure.
fFDA: Food and Drug Administration.
gIRB: Institutional Review Board.
hCFR: Code of Federal Regulation.
ieCRF: electronic case report form.
Figure 1Certain interfaces of mobile device–based electronic data capture (mEDC).Fig 1-1 Root directory for investigators and CRA to manage materials, visits, and quit register; Fig 1-2 Interface for investigators to input blood pressure and upload photo evidence of electronic sphygmomanometer screens with 2 minutes interval for each of three sequential blood pressure measurements;Fig 1-3 Current reports of recruitment and follow-ups for site investigators;Fig 1-4 Current reports of all sites for CRA and principle investigators.
Figure 2Functions and operations of mobile device–based electronic data capture (mEDC).
Demographic and other characteristics of all participants.
| Characteristics | Doctors | Patients | CRAa
| PMb
| DMc
|
| Age (years), mean (SDd) | 40.6 (4.2) | 53.5 (5.2) | 26 | 34 | 37 |
| Male (n) | 10 | 23 | 0 | 0 | 1 |
| Years of work experience, mean (SD) | 11.2 (5.1) | - | 2 | 10 | 10 |
| Prior clinical trial experience, n (%) | 7 (29.2) | - | 1 (100.0) | 1 (100.0) | |
| Possession rate of any cellphone, n (%) | 24 (100.0) | 40 (76.0) | 1 (100.0) | 1 (100.0) | |
| Possession rate of mobile phone, n (%) | 24 (100.0) | 13 (24.0) | 1 (100.0) | 1 (100.0) |
aCRA: clinical research associate.
bPM: project manager.
cDM: data manager.
dSD: standard deviation.
Three BP measurements at baseline (n=1188).
| BP | First | Second | Third | The average of later two |
| SBPa | 160.1 (10.6) | 155.3 (10.1) | 153.1 (11.6) | 154.1 (11.1) |
| DBPb | 99.3 (8.9) | 94.5 (8.7) | 91.3 (9.3) | 92.8 (8.8) |
aSBP: systolic blood pressure.
bDBP: diastolic blood pressure.
Satisfaction scores with mobile device–based electronic data capture (mEDC) from 24 doctors.
| No. | Procedures | No. of participants | Satisfaction score | |
| 1 | ||||
| Inclusion and exclusion | 0/18 | 9 (8-10) | ||
| Informed consent | 0/18 | 9 (8-10) | ||
| Data collection at each visit | 0/18 | 9 (8-10) | ||
| Randomization | 0/18 | 9 (8-10) | ||
| Collection of biological samples | 0/18 | 9 (7-10) | ||
| Medicine delivery | 0/18 | 9 (7-10) | ||
| Appointment for next visit | 1/18 | 8 (6-9) | ||
| 2 | ||||
| Accounts management | 0/18 | 9 (8-10) | ||
| Logistics | 1/18 | 9 (8-10) | ||
| Patient indexing | 0/18 | 8 (6-9) | ||
| 3 | ||||
| Reminder at each step | 0/18 | 9 (8-10) | ||
| Key point control | 0/18 | 9 (8-10) | ||
| 4 | ||||
| Training for using mEDCc | 2/18 | 9 (8-10) | ||
| Wireless Internet | 0/18 | 8 (6-9) | ||
| Overall average score | 9 (6-10) | |||
aNonresponse: number of interviewees who had no response.
bTotal: total number of participants who attended the qualitative evaluation.
cmEDC: mobile device-based electronic data capture.