Literature DB >> 28273994

A Report of Successful Procedural, Clinical, and Angiographic Outcomes with a Tapered Stent of a Patient in Naturally Tapered Coronary Vessel.

Rajendra Kumar Premchand1, Yerra Shiv Kumar2.   

Abstract

In cases involving stenosis or occlusions in major parts of a long vessel, natural tapering of coronary vessels may create dilemma in deciding the optimal stent size during percutaneous coronary intervention. In this regard, tapered stents have been developed recently. Herein, we present a case of 67-year-old male patient with triple vessel disease including two tandem lesions in naturally tapered Left Anterior Descending (LAD) artery. The patient received a 3.0-2.5x60 mm Sirolimus-eluting BioMime Morph stent (Meril life Sciences, Gujarat, India) in the mid-distal LAD lesion along with conventional stent implantations in other two lesions. The procedure was successful and good coronary flow was obtained after revascularization. The patient remained asymptomatic thereafter. At one year, angiographic follow-up revealed good flow and no restenosis in the LAD vessel. We are of opinion that using tapered stents with decremented diameter may offer the advantages of excellent adaptation to vessel size, vessel tapering, and good apposition in patients with long coronary lesions in tapered vessels.

Entities:  

Keywords:  BioMime Morph; Long lesion; Percutaneous coronary intervention

Year:  2017        PMID: 28273994      PMCID: PMC5324439          DOI: 10.7860/JCDR/2017/22241.9288

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  8 in total

1.  Percutaneous balloon mitral valvotomy and coronary stenting in the same sitting.

Authors:  S Harikrishnan; Anil Bhat; Jaganmohan Tharakan
Journal:  Heart Vessels       Date:  2003-07       Impact factor: 2.037

2.  Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation.

Authors:  Lorenz Räber; Peter Jüni; Lukas Löffel; Simon Wandel; Stéphane Cook; Peter Wenaweser; Mario Togni; Rolf Vogel; Christian Seiler; Franz Eberli; Thomas Lüscher; Bernhard Meier; Stephan Windecker
Journal:  J Am Coll Cardiol       Date:  2010-03-23       Impact factor: 24.094

3.  Effectiveness of decremental diameter balloon catheters (tapered balloon).

Authors:  V S Banka; H A Baker; D N Vemuri; G Voci; A R Maniet
Journal:  Am J Cardiol       Date:  1992-01-15       Impact factor: 2.778

4.  The importance of taper proximal and distal to Y-bifurcations in arteries.

Authors:  M R Roach; N F MacLean
Journal:  Front Med Biol Eng       Date:  1993

5.  [Coronary artery lumen diameter and bifurcation angle derived from CT coronary angiographic image in healthy people].

Authors:  Li-ren Zhang; Dong-sheng Xu; Xiao-cheng Liu; Xue-sheng Wu; Yuan-ning Ying; Zhi Dong; Feng-wei Sun; Pi-pi Yang; Xu Li
Journal:  Zhonghua Xin Xue Guan Bing Za Zhi       Date:  2011-12

6.  Screening coronary angiography prior to surgery in rheumatic valvular heart disease: a study of 2,188 patients.

Authors:  Rajiv Narang; Davinder S Chadha; Kashish Goel; Sandeep Mishra; Naveen Bajaj; Sanjeev Sharma; Nidhi Gupta; Vinay K Bahl
Journal:  J Heart Valve Dis       Date:  2009-07

7.  Mechanical modeling of stents deployed in tapered arteries.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  Ann Biomed Eng       Date:  2008-10-10       Impact factor: 3.934

8.  The Role of Self-expanding Stents in Patients with Atypical Coronary Anatomy.

Authors:  Robert-Jan van Geuns; Katherin Awad; Alexander IJsselmuiden; Karel Koch
Journal:  Interv Cardiol       Date:  2014-03
  8 in total
  2 in total

1.  Clinical Outcomes of Novel Long-Tapered Sirolimus-Eluting Coronary Stent System in Real-World Patients With Long Diffused De Novo Coronary Lesions.

Authors:  Suresh V Patted; Rajendra Kumar Jain; P A Jiwani; Satish Suryavanshi; T R Raghu; Hema Raveesh; S Rajalakshmi; Ashok S Thakkar; Prakash Kumar Turiya; Priyanka J Desai; Anmol Suresh Patted; Kamal H Sharma
Journal:  Cardiol Res       Date:  2018-12-07

2.  Clinical experience with 12-month follow-up in patients after implantation of a novel long-tapered sirolimus drug-eluting stent.

Authors:  Jakub Podolec; Maciej Skubera; Łukasz Niewiara; Mateusz Podolec; Piotr Pieniążek; Krzysztof Bartuś; Krzysztof Żmudka; Jacek Legutko
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-03-15       Impact factor: 1.426

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.