Effectiveness of decremental diameter balloon catheters (tapered balloon).

V S Banka1, H A Baker, D N Vemuri, G Voci, A R Maniet.   

Abstract

Natural tapering of coronary arteries from larger proximal to smaller distal diameters often creates a dilemma for optimal balloon sizing during percutaneous transluminal coronary angioplasty (PTCA). To demonstrate the need for new dilating catheters suitable for tapered coronary anatomy, 100 consecutive coronary arteries were measured by videodensitometry, 1 cm proximal and distal to the stenosis. In 23 arteries there was a 1 mm or greater taper and 19 arteries showed a 0.5 to 0.99 mm taper. Only 50 arteries showed a nearly uniform diameter at the site of the stenosis, and 8 arteries demonstrated reverse taper, i.e., distal was greater than proximal diameter. To avoid balloon size mismatch with significant tapering, decremental diameter balloon catheters were developed. Series I tapers from 3.5 to 3.0 mm and series II from 3.0 to 2.5 mm over a balloon length of 25 mm. Tapered balloons were used in 80 patients with 94 tapered coronary arteries. Before PTCA, proximal, stenotic and distal mean diameters measured 3.6, 1.1 and 2.6 mm, respectively; after PTCA, proximal, stenotic and distal diameters measured 3.6, 2.8 and 2.5 mm, respectively, thus maintaining the natural tapering after effective dilatation. Only 2 arteries (2.1%) showed significant dissection, with no abrupt occlusions, and none requiring bypass surgery. In summary, decremental diameter balloon catheters provide optimal dilation in tapered arterial segments with few complications and offer a new approach to balloon sizing.

Entities:  

Mesh:

Year:  1992        PMID: 1731458     DOI: 10.1016/0002-9149(92)91303-l

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  A Report of Successful Procedural, Clinical, and Angiographic Outcomes with a Tapered Stent of a Patient in Naturally Tapered Coronary Vessel.

Authors:  Rajendra Kumar Premchand; Yerra Shiv Kumar
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  Image-based quantification of 3D morphology for bifurcations in the left coronary artery: Application to stent design.

Authors:  Laura Ellwein; David S Marks; Raymond Q Migrino; W Dennis Foley; Sara Sherman; John F LaDisa
Journal:  Catheter Cardiovasc Interv       Date:  2015-11-19       Impact factor: 2.692

3.  Comparative study of tapered versus conventional cylindrical balloon for stent implantation in stenotic tapered artery.

Authors:  Xiang Shen; Jiabao Jiang; Hongfei Zhu; Kaikai Lu; Pengfei Dong; Linxia Gu
Journal:  Artif Organs       Date:  2020-03-01       Impact factor: 2.663

4.  Clinical Outcomes of Novel Long-Tapered Sirolimus-Eluting Coronary Stent System in Real-World Patients With Long Diffused De Novo Coronary Lesions.

Authors:  Suresh V Patted; Rajendra Kumar Jain; P A Jiwani; Satish Suryavanshi; T R Raghu; Hema Raveesh; S Rajalakshmi; Ashok S Thakkar; Prakash Kumar Turiya; Priyanka J Desai; Anmol Suresh Patted; Kamal H Sharma
Journal:  Cardiol Res       Date:  2018-12-07
  4 in total