Literature DB >> 28272929

Perfusion of the Rotator Cuff Tendon According to the Repair Configuration Using an Indocyanine Green Fluorescence Arthroscope: A Preliminary Report.

Sae Hoon Kim1, Won-Sang Cho2, Ho-Yun Joung1, Young Eun Choi1, Minwoong Jung3.   

Abstract

BACKGROUND: The disturbance of rotator cuff tendon perfusion has been connected with the suture-bridge configuration repair (SBCR) technique; however, in vivo assessments of the tendon blood supply have been problematic with other modalities. An evaluation of tissue perfusion by an indocyanine green (ICG) fluorescence arthroscope has been developed to counteract this difficulty.
PURPOSE: To verify the hindrance of perfusion in SBCR, we used an ICG fluorescence camera to compare parallel-type transosseous repair (PTR) and SBCR in rabbits immediately and at 3 days after rotator cuff repair. STUDY
DESIGN: Controlled laboratory study.
METHODS: Acute rotator cuff repair was performed on the shoulders of 10 rabbits. Both shoulders were repaired using either PTR or SBCR. For PTR, simple repair was performed through 2 parallel transosseous tunnels created using a microdrill. For SBCR, 2 additional crisscross transosseous tunnels were added to mimic arthroscopic SBCR. Immediately after repair, ICG was injected through the ear vein, and images were recorded using an ICG fluorescence camera. Tendon perfusion was compared by measuring fluorescence intensity using ImageJ software in both methods. At 3 days after rotator cuff repair, a reassessment of ICG fluorescence was performed. In addition, as a subsidiary study, a comparison of each repair method and a healthy tendon was performed (PTR vs healthy tendon and SBCR vs healthy tendon). Six rabbits (3 for each comparison) were included.
RESULTS: Immediately after rotator cuff repair, the mean (±SD) grayscale intensity of ICG fluorescence was weaker in SBCR than PTR in 10 specimens (65.9 ± 47.6 vs 84.3 ± 53.4 per pixel, respectively; P = .003). At 3 days after repair, 8 specimens were included in the analysis because suture strands failed in 2 specimens in SBCR. The mean intensity of fluorescence was still weaker in SBCR compared with PTR (52.5 ± 13.7 vs 60.2 ± 22.7 per pixel, respectively; P = .077). The mean fluorescence intensity compared with a healthy tendon was 83.2% ± 9.5% in PTR and 63.2% ± 13.2% in SBCR.
CONCLUSION: Our ICG fluorescence camera system was able to detect ICG fluorescence in an acute rabbit rotator cuff repair model. SBCR showed inferior tendon perfusion immediately after repair. At 3 days after repair, SBCR still showed inferior fluorescence intensity, although it did not reach statistical significance. CLINICAL RELEVANCE: In this study, SBCR hindered perfusion at the tendon in the compressed area. This finding may affect rotator cuff tendon healing and failure mode.

Entities:  

Keywords:  ICG fluorescence arthroscope; parallel-type transosseous repair; rotator cuff tear; suture-bridge configuration repair; tendon ischemia; tendon perfusion

Mesh:

Substances:

Year:  2016        PMID: 28272929     DOI: 10.1177/0363546516669778

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  6 in total

1.  Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair.

Authors:  Carlos Maia Dias; Sérgio B Gonçalves; António Completo; Manuel Ribeiro da Silva; Clara de Campos Azevedo; Jorge Mineiro; Frederico Ferreira; João Folgado
Journal:  J Exp Orthop       Date:  2022-09-19

2.  Effects of Knee Debridement with Flurbiprofen on Knee Function, Inflammatory Levels, and Bone Metabolism Activity in Patients with Knee Osteoarthritis.

Authors:  Tao Lin; Zemiao Liu; Wei Ji; Peng Zhang
Journal:  Comput Math Methods Med       Date:  2022-07-01       Impact factor: 2.809

3.  From Bench to Bedside: Semper Gumby-Like Living Tissue, Let's Stay Flexible.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

4.  Intraoperative evaluation of blood flow for soft tissues in orthopaedic surgery using indocyanine green fluorescence angiography: A pilot study.

Authors:  N Doi; T Izaki; S Miyake; T Shibata; T Ishimatsu; Y Shibata; T Yamamoto
Journal:  Bone Joint Res       Date:  2019-04-02       Impact factor: 5.853

Review 5.  Does Medial-Row Fixation Technique Affect the Retear Rate and Functional Outcomes After Double-Row Transosseous-Equivalent Rotator Cuff Repair?

Authors:  Ameer M Elbuluk; Francesca R Coxe; Peter D Fabricant; Nicholas L Ramos; Michael J Alaia; Kristofer J Jones
Journal:  Orthop J Sports Med       Date:  2019-05-16

6.  Why are tapes better than wires in knotless rotator cuff repairs? An evaluation of force, pressure and contact area in a tendon bone unit mechanical model.

Authors:  Carlos Maia Dias; Sérgio B Gonçalves; António Completo; Martina Tognini; Manuel Ribeiro da Silva; Jorge Mineiro; Francisco Curate; Frederico Ferreira; João Folgado
Journal:  J Exp Orthop       Date:  2021-02-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.