Literature DB >> 28267541

Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.

Boris Bodelle1, Constanze Fischbach2, Christian Booz2, Ibrahim Yel2, Claudia Frellesen2, Martin Beeres2, Thomas J Vogl2, Jan-Erik Scholtz2.   

Abstract

OBJECTIVES: To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT).
MATERIALS AND METHODS: The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated.
RESULTS: Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p<0.01). Motion artifacts were reduced significantly (p=0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p<0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82mGy vs. 0.92mGy, p<0.02; median ED: 0.4 mSv vs. 0.48mSv, p=0.02).
CONCLUSIONS: High-pitch 80kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chest CT; Free breathing; High pitch CT; Pediatric CT; Third generation dual-source CT

Mesh:

Year:  2017        PMID: 28267541     DOI: 10.1016/j.ejrad.2017.01.027

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Chest CT screening in patients with overweight or obesity using spectral shaping at 150 kVp: compared with 120 kVp protocol and spectral shaping at 100 kVp protocol.

Authors:  Jianwen Li; Zhifeng Mai; Zhihong Zhang; Jiamang Cui; Mingjie Yang; Xia Ma; Yan Wang
Journal:  Jpn J Radiol       Date:  2020-02-11       Impact factor: 2.374

Review 2.  Assessing and conveying risks and benefits of imaging in neonates using ionizing radiation and sedation/anesthesia.

Authors:  Gary R Schooler; Joseph P Cravero; Michael J Callahan
Journal:  Pediatr Radiol       Date:  2021-07-20

Review 3.  User-Friendly Vendor-Specific Guideline for Pediatric Cardiothoracic Computed Tomography Provided by the Asian Society of Cardiovascular Imaging Congenital Heart Disease Study Group: Part 1. Imaging Techniques.

Authors:  Sun Hwa Hong; Hyun Woo Goo; Eriko Maeda; Ki Seok Choo; I Chen Tsai
Journal:  Korean J Radiol       Date:  2019-02       Impact factor: 3.500

4.  The ultrafast, high-pitch turbo FLASH mode of third-generation dual-source CT: Effect of different pitch and corresponding SFOV on image quality in a phantom study.

Authors:  Yang Zhou; Lei Hu; Silin Du; Rui Jin; Wangjia Li; Fajin Lv; Zhiwei Zhang
Journal:  J Appl Clin Med Phys       Date:  2021-11-09       Impact factor: 2.102

5.  Evaluation of ultralow-dose computed tomography on detection of pulmonary nodules in overweight or obese adult patients.

Authors:  Xiaowan Guo; Dezhao Jia; Lei He; Xudong Jia; Danqing Zhang; Yana Dou; Shanshan Shen; Hong Ji; Shuqian Zhang; Yingmin Chen
Journal:  J Appl Clin Med Phys       Date:  2022-03-16       Impact factor: 2.102

Review 6.  Dual-source computed tomography protocols for the pediatric chest - scan optimization techniques.

Authors:  Jordan B Rapp; Victor M Ho-Fung; Karen I Ramirez; Ammie M White; Hansel J Otero; David M Biko
Journal:  Pediatr Radiol       Date:  2022-08-11

7.  Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: a feasibility study.

Authors:  Andrea Agostini; Chiara Floridi; Alessandra Borgheresi; Myriam Badaloni; Paolo Esposto Pirani; Filippo Terilli; Letizia Ottaviani; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2020-04-01       Impact factor: 6.313

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.