| Literature DB >> 28264237 |
Do Keun Kim1, Ji Yong Kim2, Do Yeon Kim3, Seung Chul Rhim4, Seung Hwan Yoon1.
Abstract
OBJECTIVE: Proximal junctional kyphosis (PJK) is radiologic finding, and is defined as kyphosis of >10° at the proximal end of a construct. The aim of this study is to identify factors associated with PJK after segmental spinal instrumented fusion in adults with spinal deformity with a minimum follow-up of 2 years.Entities:
Keywords: Adult spinal deformity; Back muscle; Complication; Osteoporosis; Proximal junctional kyphosis; Sarcopenia
Year: 2017 PMID: 28264237 PMCID: PMC5365283 DOI: 10.3340/jkns.2016.0707.014
Source DB: PubMed Journal: J Korean Neurosurg Soc ISSN: 1225-8245
Fig. 1C7PL was defined distance between C7 plumb line which is the vertical line originating the center of the C7 vertebral body and the posterior superior corner of S1, and its length was measured preoperatively and at ÿnal follow-up. The distance between the center of the UIV and C7PL was also measured early postoperatively and at final follow-up. C7PL: C7 plumb line, UIV: uppermost instrumented vertebra.
Fig. 2Thoracolumbar back muscle volumes were measured from T10 to L2 in T2 weighted magnetic resonance images.
Patient demographics
| Variable | Group A (n=16) | Group B (n=33) | |
|---|---|---|---|
| PJK | Non-PJK | ||
| Sex (male: female) | 2: 14 | 4: 29 | 0.104 |
| Age (mean, years) | 62.5 (56–69) | 61.9 (54–69) | 0.408 |
| Mean follow up period (months) | 47.7±23.4 | 45.6±25.6 | 0.392 |
| BMD (T score) | −2.30±0.85 | −1.01±0.67 | 0.027 |
| C7PL in Pre-Op (mm) | 89.85±51.60 | 58.97±66.98 | 0.111 |
| C7PL in FF (mm) | 71.96±58.04 | 55.83±37.00 | 0.423 |
| UIV distance to C7PL in EP (mm) | 1.9±6.0 | 0.5±3.0 | 0.444 |
| UIV distance to C7PL in FF (mm) | −5.5±5.4 | −2.5±3.4 | 0.019 |
| SS in Pre-OP (°) | 15.38±5.88 | 16.91±6.59 | 0.433 |
| PT in Pre-Op (°) | 42.06±12.00 | 41.21±9.16 | 0.785 |
| PI in Pre-Op (°) | 57.94±12.70 | 58.45±8.37 | 0.865 |
| Anterior-posterior | 6 (37.5) | 16 (48.4) | 0.468 |
| Use of cross-links | 13 (81.2) | 26 (78.8) | 0.841 |
| Screw & rod fracture | 5 (31.2) | 10 (30.0) | 0.946 |
| UIV Level (T10) | 2 (12.5) | 5 (15.1) | 0.804 |
| UIV Level (T11) | 3 (18.8) | 4 (12.2) | 0.534 |
| UIV Level (T12) | 5 (31.2) | 12 (36.3) | 0.724 |
| UIV Level (L1) | 4 (25.0) | 6 (18.2) | 0.579 |
| UIV Level (L2) | 2 (12.5) | 6 (18.2) | 0.614 |
| Muscle volume, T10 (mm2) | 1042±149 | 1315±143 | <0.001 |
| Muscle volume, T11 (mm2) | 1113±101 | 1445±176 | <0.001 |
| Muscle volume, T12 (mm2) | 1227±111 | 1603±230 | <0.001 |
| Muscle volume, L1 (mm2) | 1333±99 | 1783±326 | <0.001 |
| Muscle volume, L2 (mm2) | 1443±175 | 1905±303 | <0.001 |
Values are presented as number (%) or mean±standard deviation. PJK: proximal junctional kyphosis, BMD: bone mineral density, UIV: upper instrumented vertebra, C7PL: C7 plumb line, EP: early post-op, FF: final follow-up, SS: sacral slope, PT: pelvic tilt, PI: pelvic incidence
Fig. 3Di°erences in muscle volume (mm2) of two study groups. PJK: proximal junctional kyphosis.
Fig. 4Scatter plot showed correlation between preoperative C7PL (mm) and mean muscle volume (mm2).