Semi-Quantitative Strain Ratio Determined Using Different Measurement Methods: Comparison of Strain Ratio Values and Diagnostic Performance Using One- versus Two-Region-of-Interest Measurement.

Jung Hyun Yoon1, Mi Kyung Song2, Eun-Kyung Kim3.   

Abstract

We evaluated the agreement and diagnostic performance of strain ratio values using measurements made with one and two user-defined regions of interest (ROIs) on breast elastography. Two hundred forty-three breast masses of 226 women (mean age: 48.2 y) were included. Ultrasonography (US) and elastography images of the masses were recorded. Strain ratio was measured twice on the same elastography image; strain ratio 1, applying one ROI at the target mass for measurement, and strain ratio 2, applying one ROI at the target mass and another ROI as reference strain. The two strain ratio measurements were in substantial agreement, with an intra-class correlation coefficient of 0.655 (95% confidence interval: 0.577-0.722). Specificity, positive predictive value and accuracy (cutoffs: 2.66 and 2.35) were significantly improved for US combined with the two strain ratio measurements (all p values < 0.05). Strain ratios measured using one or two user-defined ROIs were in substantial agreement, both contributing to the improved diagnostic performance of breast US.
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  Breast; Elastography; Region of interest; Strain ratio; Ultrasonography

Mesh:

Year:  2017        PMID: 28242085     DOI: 10.1016/j.ultrasmedbio.2017.01.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Evaluation of Acoustic Radiation Force Impulse Imaging in Differentiating Benign and Malignant Cervical Lymphadenopathy.

Authors:  Kamat Rohan; Ananthakrishnan Ramesh; K Nagarajan; K M Abdulbasith; Sathasivam Sureshkumar; Chellappa Vijayakumar; K Balamourougan; B H Srinivas
Journal:  J Med Ultrasound       Date:  2021-07-29

2.  Determining the elastography strain ratio cut off value for differentiating benign from malignant breast lesions: systematic review and meta-analysis.

Authors:  Timothy Musila Mutala; Gladys N Mwango; Angeline Aywak; Dania Cioni; Emanuele Neri
Journal:  Cancer Imaging       Date:  2022-02-12       Impact factor: 3.909

3.  Comparison of One- and Two-Region of Interest Strain Elastography Measurements in the Differential Diagnosis of Breast Masses.

Authors:  Hee Jeong Park; Sun Mi Kim; Bo La Yun; Mijung Jang; Bohyoung Kim; Soo Hyun Lee; Hye Shin Ahn
Journal:  Korean J Radiol       Date:  2020-04       Impact factor: 3.500

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.