OBJECTIVE: To evaluate the accuracy of predicting the spectacle plane add power of multifocal intraocular lenses (MIOLs) based on the effective lens position (ELP) using the Haigis formula.
DESIGN: Retrospective cross-sectional study. PARTICIPANTS: A total of 26 eyes from 18 consecutive patients who underwent phacoemulsification with Tecnis MIOL (Z*B00) implantation.
METHODS: The postoperative spectacle plane add power of MIOLs was determined from the monocular defocus curve. The predicted add power error was defined as the difference between the predicted and postoperatively measured spectacle plane add power. The median absolute predicted add power error determined by the preoperatively estimated ELP using the Haigis formula was compared with power error calculated using the value presented by the manufacturer. The correlations among predicted add power error, postoperative spectacle plane add power, and back-calculated ELP were analyzed.
RESULTS: The median absolute predicted add power error calculated using the Haigis formula (0.13 D) was significantly smaller than that calculated using the value presented by the manufacturer (0.26 D). The predicted add power error determined by the value presented by the manufacturer was negatively correlated with back-calculated ELP. The postoperative spectacle plane add power was negatively correlated with back-calculated ELP in the ZKB00 IOL (n = 21).
CONCLUSIONS: The predicted spectacle plane add power of MIOLs using the ELP of the Haigis formula was more accurate than that using the value presented by the manufacturer. The spectacle plane add power of MIOLs decreased as ELP increased.
Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 28237150     DOI: 10.1016/j.jcjo.2016.07.026

Source DB:  PubMed          Journal:  Can J Ophthalmol        ISSN: 0008-4182            Impact factor:   1.882


  6 in total

1.  Full-vision maintenance in extra-high myopia from implantable collamer lens to trifocal intraocular lens implantation.

Authors:  Shu-Yang Chen; Chen Xie; Yang Wang; Ye Shen
Journal:  Int J Ophthalmol       Date:  2018-07-18       Impact factor: 1.779

2.  Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens.

Authors:  Jing Zhao; Liang-Ping Liu; Huan-Huan Cheng; Jian-Bing Li; Xiao-Tong Han; Yu Liu; Ming-Xing Wu
Journal:  Int J Ophthalmol       Date:  2020-09-18       Impact factor: 1.779

3.  Comparison of visual outcomes after two types of mix-and-match implanted trifocal extended-depth-of-focus and trifocal intraocular lenses.

Authors:  Jung Wan Kim; Youngsub Eom; Wonkyung Park; Jong Suk Song; Ji Won Jeong; Seh Kwang Park; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-05-28       Impact factor: 3.535

4.  Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

Authors:  Youngsub Eom; Dongok Ryu; Dae Wook Kim; Seul Ki Yang; Jong Suk Song; Sug-Whan Kim; Hyo Myung Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-08-19       Impact factor: 3.117

5.  Patient selection to optimize near vision performance with a low-addition trifocal lens.

Authors:  Joaquín Fernández; Manuel Rodríguez-Vallejo; Javier Martínez; Ana Tauste; David P Piñero
Journal:  J Optom       Date:  2019-11-01

6.  Exploration of the Visual Function after the Implantation of Continuous Visual Range Human Cocrystal Micromonocular Vision in Both Eyes of the Patient.

Authors:  Fangrong Cai; Xiaoli Wang; Zhihui Deng; Lina Bai
Journal:  J Healthc Eng       Date:  2022-03-07       Impact factor: 2.682