Literature DB >> 28236484

Characterization and source profiling of volatile organic compounds in indoor air of private residences in Selangor State, Malaysia.

Nobumitsu Sakai1, Shuta Yamamoto2, Yasuto Matsui2, Md Firoz Khan3, Mohd Talib Latif4, Mustafa Ali Mohd5, Minoru Yoneda2.   

Abstract

Volatile Organic Compounds (VOCs) in indoor air were investigated at 39 private residences in Selangor State, Malaysia to characterize the indoor air quality and to identify pollution sources. Twenty-two VOCs including isomers (14 aldehydes, 5 aromatic hydrocarbons, acetone, trichloroethylene and tetrachloroethylene) were collected by 2 passive samplers for 24h and quantitated using high performance liquid chromatography and gas chromatography mass spectrometry. Source profiling based on benzene/toluene ratio as well as statistical analysis (cluster analysis, bivariate correlation analysis and principal component analysis) was performed to identify pollution sources of the detected VOCs. The VOCs concentrations were compared with regulatory limits of air quality guidelines in WHO/EU, the US, Canada and Japan to clarify the potential health risks to the residents. The 39 residences were classified into 2 groups and 2 ungrouped residences based on the dendrogram in the cluster analysis. Group 1 (n=30) had mainly toluene (6.87±2.19μg/m3), formaldehyde (16.0±10.1μg/m3), acetaldehyde (5.35±4.57μg/m3) and acetone (11.1±5.95μg/m3) at background levels. Group 2 (n=7) had significantly high values of formaldehyde (99.3±10.7μg/m3) and acetone (35.8±12.6μg/m3), and a tendency to have higher values of acetaldehyde (23.7±13.5μg/m3), butyraldehyde (3.35±0.41μg/m3) and isovaleraldehyde (2.30±0.39μg/m3). The 2 ungrouped residences showed particularly high concentrations of BTX (benzene, toluene and xylene: 235μg/m3 in total) or acetone (133μg/m3). The geometric mean value of formaldehyde (19.2μg/m3) exceeded an 8-hour regulatory limit in Canada (9μg/m3), while those in other compounds did not exceed any regulatory limits, although a few residences exceeded at least one regulatory limit of benzene or acetaldehyde. Thus, the VOCs in the private residences were effectively characterized from the limited number of monitoring, and the potential health risks of the VOCs exposure, particularly formaldehyde, should be considered in the study area.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Characterization; GC–MS; HPLC; Indoor air; Source profiling; Volatile organic compounds

Mesh:

Substances:

Year:  2017        PMID: 28236484     DOI: 10.1016/j.scitotenv.2017.02.139

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  3 in total

1.  Assessment of the Endocrine-Disrupting Effects of Trichloroethylene and Its Metabolites Using in Vitro and in Silico Approaches.

Authors:  Phum Tachachartvanich; Rapeepat Sangsuwan; Heather S Ruiz; Sylvia S Sanchez; Kathleen A Durkin; Luoping Zhang; Martyn T Smith
Journal:  Environ Sci Technol       Date:  2018-01-19       Impact factor: 9.028

2.  Assessing BTEX concentrations emitted by hookah smoke in indoor air of residential buildings: health risk assessment for children.

Authors:  Zeynab Tabatabaei; Mohammad Ali Baghapour; Mohammad Hoseini; Mohammad Fararouei; Fariba Abbasi; Melika Baghapour
Journal:  J Environ Health Sci Eng       Date:  2021-09-09

3.  Biomarkers of Low-Level Environmental Exposure to Benzene and Oxidative DNA Damage in Primary School Children in Sardinia, Italy.

Authors:  Ilaria Pilia; Marcello Campagna; Gabriele Marcias; Daniele Fabbri; Federico Meloni; Giovanna Spatari; Danilo Cottica; Claudio Cocheo; Elena Grignani; Fabio De-Giorgio; Pierluigi Cocco; Ernesto d'Aloja
Journal:  Int J Environ Res Public Health       Date:  2021-04-27       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.