Literature DB >> 28233370

An In Vitro Feasibility Study of the Influence of Configurations and Leaflet Thickness on the Hydrodynamics of Deformed Transcatheter Aortic Valve.

Wentao Feng1,2, Xianda Yang1,2, Yang Liu1,2, Yubo Fan1,2,3.   

Abstract

Clinically, the percutaneous transcatheter aortic valve (TAV) has been reported to be deformed in a noncircular configuration after its implant. The deformation is universal and various, and it leads to serious leakage and durability problems. Even in the same deformation, the leaflets made in different tissue thicknesses may cause different hydrodynamic performances. Simulating the left heart cardiac conditions by a pulse duplicator system, the present study investigated the effects of the aortic annulus deformation and the leaflet tissue thickness on the hydrodynamics of the TAV. Three 22 mm self-expanding TAV samples were fabricated with three different leaflet thicknesses (0.25, 0.4, 0.55 mm). Every sample was successively deformed to be elliptical, triangular, and undersized circular shapes. The hydrodynamics of the TAV were assessed through a quasi-physiological artery pulsatile flow duplicator system. The transvalvular pressure difference, effective orifice area, and regurgitation flow were determined. High-speed video recordings were taken to investigate the leaflet kinematics. The results showed that the triangular deformation produced the poorest valve function while the elliptical deformation led to the slightest difference from the nominal. With increasing leaflet thickness, the effect of configuration deformation on the regurgitation increased. The thinner leaflets were better than the thicker ones in adapting to the deformation but had a higher risk of deterioration.
© 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Aortic valve stenosis; Heart valve prosthesis; In vitro study; Transcatheter aortic valve implantation

Mesh:

Year:  2017        PMID: 28233370     DOI: 10.1111/aor.12833

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Simulated Transcatheter Aortic Valve Flow: Implications of Elliptical Deployment and Under-Expansion at the Aortic Annulus.

Authors:  Eric Sirois; Wenbin Mao; Kewei Li; Joseph Calderan; Wei Sun
Journal:  Artif Organs       Date:  2018-04-02       Impact factor: 3.094

2.  Transapical mitral valve-in-valve implantation for failed bioprosthetic valve using the J-valve system with locator device: early and mid-term outcomes.

Authors:  Kun Liu; Jinglun Shen; Kaisheng Wu; Fei Meng; Shengxun Wang; Shuai Zheng; Haibo Zhang
Journal:  Ann Transl Med       Date:  2022-01

Review 3.  Three-dimensional printing for cardiovascular diseases: from anatomical modeling to dynamic functionality.

Authors:  Hao Wang; Hongning Song; Yuanting Yang; Quan Cao; Yugang Hu; Jinling Chen; Juan Guo; Yijia Wang; Dan Jia; Sheng Cao; Qing Zhou
Journal:  Biomed Eng Online       Date:  2020-10-07       Impact factor: 2.819

  3 in total