Literature DB >> 28222859

Determination of benzimidazoles in meat samples by capillary zone electrophoresis tandem mass spectrometry following dispersive liquid-liquid microextraction.

Carmen Tejada-Casado1, David Moreno-González1, Francisco J Lara1, Ana M García-Campaña1, Monsalud Del Olmo-Iruela2.   

Abstract

A novel method based on capillary zone electrophoresis-tandem mass spectrometry has been proposed and validated for the identification and simultaneous quantification of twelve benzimidazoles in meat samples. Electrophoretic separation was carried out using 500mM formic acid (pH 2.2) as background electrolyte and applying a voltage of 25kV at 25°C. In order to improve the sensitivity, stacking mode injection was applied, using as injection solvent a mixture of 30:70 acetonitrile/water at 50mbar for 75s. Sensitivity enhancement factors from 74 to 317 were obtained under these conditions. Detection using an ion trap as analyzer, operating in multiple reactions monitoring mode was employed. The main MS/MS parameters as well as the composition of the sheath liquid and other electrospray variables were optimized in order to obtain the highest sensitivity and precision in conjunction with an unequivocal identification. The method was applied to poultry and pork muscle samples. The deproteinization of samples and extraction of benzimidazoles was carried out with acetonitrile. MgSO4 and NaCl were added as salting-out agents. Subsequently, dispersive liquid-liquid microextraction was applied as clean up procedure. The organic layer (acetonitrile, used as dispersant) containing the benzimidazoles was mixed with the extractant (chloroform) and both were injected in water, producing a cloudy solution. Recoveries for fortified samples were higher than 70%, with relative standard deviations lower than 16% were obtained in all cases. The limits of detection were below 3μgkg-1, demonstrating the applicability of this fast, simple, and environmentally friendly method.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Benzimidazoles; Capillary electrophoresis; Dispersive liquid–liquid micro extraction; Mass spectrometry; Meat samples

Mesh:

Substances:

Year:  2017        PMID: 28222859     DOI: 10.1016/j.chroma.2017.02.023

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Determination of benzimidazoles in fruits by open-tubular capillary electrochromatography based on ionic liquids grafted covalent organic frameworks.

Authors:  Cuicui Liu; Buyi Zhao; Xiaobing Liu; Ailin Zhang
Journal:  Anal Sci       Date:  2022-07-12       Impact factor: 1.967

2.  Capillary Electromigration Techniques Coupled to Mass Spectrometry: Applications to Food Analysis.

Authors:  Vijay D Patel; Shahab A Shamsi; K Sutherland
Journal:  Trends Analyt Chem       Date:  2021-02-25       Impact factor: 14.908

Review 3.  Advances in the Analysis of Veterinary Drug Residues in Food Matrices by Capillary Electrophoresis Techniques.

Authors:  Raffaella Colombo; Adele Papetti
Journal:  Molecules       Date:  2019-12-17       Impact factor: 4.411

4.  Hapten Synthesis and Monoclonal Antibody Preparation for Simultaneous Detection of Albendazole and Its Metabolites in Animal-Origin Food.

Authors:  Shibei Shao; Xuping Zhou; Leina Dou; Yuchen Bai; Jiafei Mi; Wenbo Yu; Suxia Zhang; Zhanhui Wang; Kai Wen
Journal:  Foods       Date:  2021-12-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.