Literature DB >> 28210180

Normal values of intraocular pressure in full-term Nigerian newborns.

Victoria Ayodeji Olatunji1, Dupe Ademola-Popoola2, Feyi Grace Adepoju2, Omotayo Olukemi Adesiyun3.   

Abstract

PURPOSE: To determine the normative range of intraocular pressure (IOP) in full-term newborns and possible association with birth parameters during the first week of life.
METHODS: This was an observational cross sectional study in which IOP was measured in 1000 eyes of 500 normal full-term newborns using the Perkins applanation tonometer under topical anesthesia. An average of three readings was taken as the IOP value. The relationship between IOP and birth parameters was analyzed.
RESULTS: The male to female ratio was 1:1 with 254 (50.8%) male and 246 (49.2%) female babies. The (mean ± SD) value of IOP in the right eyes was 11.93 ± 1.80 mmHg, ranging between 9.00 and 16 mmHg. In the left eyes, the mean value of IOP was 11.84 ± 1.77 mmHg with a range of 8.00-15.00 mmHg. IOP in males (12.02 ± 1.84 mmHg) was not significantly different from that in females (11.89 ± 1.75 mmHg). There was no significant difference between right and left eyes (p = 0.42). The 95% range (mean ± 2 SD) was 15.53 mmHg for the right eye and 15.38 mmHg for the left. Correlational analysis showed that birth weight and gestational age were positively correlated with IOP.
CONCLUSION: This study provides useful normative data on IOP among Nigerian full-term newborns. Further studies on possible ethnic/geographic variations of IOP in children may be beneficial.

Entities:  

Keywords:  Birth weight; Full-term; Gestational age; Intraocular pressure; Newborn

Year:  2016        PMID: 28210180      PMCID: PMC5299109          DOI: 10.1016/j.sjopt.2016.07.001

Source DB:  PubMed          Journal:  Saudi J Ophthalmol        ISSN: 1319-4534


Introduction

The diagnosis of congenital/pediatric glaucoma is usually clinically obvious from the characteristic symptoms/signs of tearing, photophobia, blepharospasm, corneal haze or enlargement, optic nerve changes and raised intraocular pressure (IOP). Tonometry is of great importance in the management of these patients which is basically aimed at lowering the IOP. It is an important tool in early diagnosis and monitoring of this significant cause of childhood blindness. From previous studies, varying values of IOP have been reported in newborns using different instruments. Radtke and Cohan documented a mean value of 11.4 ± 2.4 mmHg in newborns. A Korean study among newborns on the second day of life found a mean value of 13 ± 3.4 mmHg with tonopen while Reddy and Rosnita reported a higher mean IOP value of 15.99 ± 2.79 mmHg also using the Tonopen in a group of Malaysian newborns. Another study however, observed a mean much lower IOP value of 9.59 ± 2.3 mmHg also at birth. In spite of this variability, data on normative values of IOP in African, Nigerian children and newborns in particular are not well-documented. Presently, the values used for African children are those obtained from Caucasians; hence, the present study was carried out to determine normal values of IOP in Nigerian newborns.

Materials and methods

This observational cross-sectional study was carried out between August and October 2011 in a University teaching hospital in the north central geopolitical zone of Nigeria. Healthy full-term neonates born in the hospital within the study period were enrolled into the study. Ethical approval was obtained from the ethical review committee of the Hospital and informed consent was taken from all mothers. A total of 500 consecutive babies of consenting mothers had IOP measurement in both eyes. All newborns included were products of full-term normal (37–42 weeks of gestation) pregnancies, and had no ocular or systemic congenital anomalies. Exclusion criteria were uncertain gestational age, products of multiple pregnancy, history of antenatal conditions likely to cause intrauterine growth retardation and stillbirth. Some babies were also excluded due to small palpebral fissures interfering with IOP measurement. Neonates were certified healthy by a pediatrician before enrollment into the study. Intraocular pressure was measured in 1000 eyes of 500 newborns under topical anesthesia within the first week of life while subjects were still in the postnatal wards. Amethocaine hydrochloride eyedrops (0.5%) and sodium fluorescein dye (0.25%) were instilled and measurements were taken with the Perkins handheld applanation tonometer (Clement-Clarke, Inc., Columbus, OH). Measurements were made when the babies were quiet and put up no resistance. Three readings were taken from each eye and an average of the readings was taken as the IOP. Povidone iodine drops (5%) were instilled into both eyes after the measurements. Eyelid speculum was not used but the eyelids were gently parted with the examiner’s index finger and thumb taking care not to put pressure on the globe. All measurements were taken by one of the authors (VAO; an Ophthalmologist) between 10 am and 1 pm in order to maintain standardization. Anthropometric measurements (birth weight, head circumference, baby length) were taken by trained staff within the first hour of life. Postnatal age and gender were also recorded. Gestational age was estimated from the last menstrual period and recorded in days. Statistical analysis: Analysis of data was performed with SPSS (Statistical Package for Social Sciences) version 16. Mean, standard deviation, median and range were calculated. Differences between data sample means were determined using Student’s t-test. To analyze the association between IOP and birth parameters, Pearson’s correlation coefficients were calculated. P value of less than 0.05 was considered statistically significant.

Results

All the patients were Nigerians. Majority (84%) of them belonged to the ‘Yoruba’ ethnicity, a major ethnic group in the country. Out of the 500 babies examined, there were 254 (50.8%) males and 246 (49.2%) females, with male to female ratio being 1:1. Table 1 shows the mean gestational age, mean birth weight and other parameters. There was no significant gender difference in these parameters.
Table 1

Birth parameters.

TotalMalesFemalesp value
Number500254 (50.8%)246 (49.2%)
Mean ± SD (range)
Post natal age (h)47.1 ± 4.9(1.0–156.0)52.7 ± 4.9(1.0–156.0)42.6 ± 4.7(1.0–156.0)0.06
Gestational age (day)271.3 ± 10.8(259.0–294.0)271.3 ± 10.9(259.0–294.0)270.8 ± 10.6(259.0–294.0)0.35
Birth weight (kg)3.06 ± 0.4(2.2-4.5)2.98 ± 0.4(2.2-4.0)3.12 ± 0.5(2.3–4.5)0.07
Length (cm)50.7 ± 6.1(42.0–62.0)51.2 ± 5.9(42.0–62.0)50.2 ± 6.2(44.0–62.0)0.06
Head circumference (cm)34.1 ± 1.8(31.0–38.0)34.4 ± 1.9(31.0–38.0)34.2 ± 1.6(31.0–38.0)0.96
The IOP in the right eye ranged from 9.00 to 16.00 mmHg with a mean of 11.93 ± 1.80 mmHg while in the left eye, IOP ranged from 8.00 to 15.00 mmHg with a mean value of 11.84 ± 1.77 mmHg. A comparison of the right and left eye values showed that there was no statistically significant difference between the two eyes (p = 0.42). Figure 1, Figure 2 show the distribution of IOP in the right and left eyes. IOP was similar between the genders, showing no statistically significant difference (Table 2).
Figure 1

Frequency distribution of intraocular pressure in the right eyes (IOPR; mmHg).

Figure 2

Frequency distribution of intraocular pressure in the left eyes (IOPL; mmHg).

Table 2

Intraocular pressure by gender.

Right eye (n = 500)
Left eye (n = 500)
Male (n = 254)Female (n = 246)p valueMale (n = 254)Female (n = 246)p value
Mean12.0211.890.1611.9011.790.70
SD1.841.751.751.79
Range9.00–15.009.00–16.008.00–15.008.00–15.00
The correlation coefficient of IOP with birth weight was 0.45 (p < 0.001), while for gestational age it was 0.31 (p < 0.001). Other birth parameters showed no significant correlation with IOP. Table 3 depicts that babies with birth weight above 3.5 kg had significantly (p < 0.05) higher IOP in either eye than babies with low or normal birth weight.
Table 3

Birth weight and IOP.

Birth weightIOPRIOPL
<2.5 kg
N2424
Mean12.0011.73
SD0.921.08
Range10.00–14.008.00–13.00



2.5–3.5 kg
N416416
Mean11.9411.92
SD1.781.71
Range9.00–16.009.00–15.00



>3.5 kg
N6060
Mean12.95#13.01#
SD1.771.96
Range10.00–16.0010.00–15.00

N: sample size, SD: standard deviation.

p < 0.05 compared with < 2.5 kg and 2.5–3.5 kg groups.

Discussion

Our study evaluated IOP among a large group of healthy full-term newborns. The mean IOP as found among full-term newborns in this study was 11.93 ± 1.80 mmHg in the right eye and 11.84 ± 1.77 mmHg in the left eye with a range of 8–16 mmHg. Radtke and Cohan previously documented a mean value of 11.4 ± 2.4 mmHg in newborns which is similar to our result. A Korean study among newborns on the second day of life found a mean value of 13 ± 3.4 mmHg while Pensiero et al., observed a mean IOP of 9.59 ± 2.3 mmHg at birth. However, some reports from other parts of the world are not in agreement. Reddy and Rosnita reported a higher mean IOP value of 15.99 ± 2.79 mmHg with a range of 8–22 mmHg using the Tonopen in a group of 150 Malaysian newborns. A higher mean value was also found among a cohort of 33 Caucasian newborns. Some of these differences may probably be attributed to variation in the instruments used, use of lid speculum, and possibly ethnic variation. Overestimation of IOP when greater than 16 mmHg in children with congenital glaucoma was reported previously.7, 8 However, Iester et al., did not find any significant difference in the instruments. Lower IOP values have also been reported from other studies.10, 11 We did not find any statistically significant difference in IOP between the genders or either eye. Similarly previous studies have reported an insignificant relationship.5, 11, 12 In full-term newborns, within the first two weeks of life, studies from Italy reported a mean value of 17 ± 2.6 mmHg with a range of 12–22 mmHg. A range of 8–22 and mean of 15.99 ± 2.79 mmHg was documented in full-term Asian newborns. The result of the current study suggests that a range of IOP between 8 and 16 mmHg is normal among Nigerian full-term newborns in the first week of life. A geographical or racial approach for defining the normal IOP range in newborns may therefore be adopted based on the variation in different studies. Analysis in the present study indicates that IOP within the first week of life showed a moderate positive correlation with birth weight while gestational age showed a weak correlation. In accordance with this, other authors have also reported weak or non-significant correlation of intraocular pressure with birth weight.13, 14 In contrast to our findings, Ng and colleagues found a strong negative association between intraocular pressure and birth weight in a longitudinal study. The result from the longitudinal study may be more conclusive compared to cross sectional studies. Perkins handheld tonometer was employed for IOP measurement in the current study since it is more readily available and affordable. Furthermore, it is well-correlated with and uses the same principle as the Goldmann tonometer which is the gold standard. In order to minimize the error in IOP measurement in babies with small interpalpebral fissure, IOP can be taken with tonopen and the average value of two readings can be taken as the IOP. We did not use lid speculum in measuring the IOP in the present study as it is known that it contributes to measurement variability. Epley et al., previously reported that lid speculum increases IOP by an average of 4 mmHg. We avoided the error of falsely raised IOP by lightly resting the parting fingers on the patients’ orbital rim and excluding those in which this was cumbersome because of small interpalpebral fissures. This study has contributed to the existing data on IOP in full-term newborns and to the best of our knowledge is the first of such on Nigerian children. It will enhance the practice of pediatric ophthalmology in Africa. Further studies on different ethnic populations and age groups in children are necessary to establish normative IOP data.

Conflict of interest

We have no conflict of interest to declare.
  15 in total

1.  The effect of an eyelid speculum on intraocular pressure measurement in children.

Authors:  K David Epley; Lawrence Tychsen; Gregg T Lueder
Journal:  Am J Ophthalmol       Date:  2002-12       Impact factor: 5.258

2.  Corneal diameter, axial length, and intraocular pressure in premature infants.

Authors:  S M Tucker; R W Enzenauer; A V Levin; J D Morin; J Hellmann
Journal:  Ophthalmology       Date:  1992-08       Impact factor: 12.079

3.  A longitudinal study to establish the normative value and to evaluate perinatal factors affecting intraocular pressure in preterm infants.

Authors:  Pak Cheung Ng; Barbara Sau Man Tam; Cheuk Hon Lee; Samuel Po Shing Wong; Hugh Simon Lam; Alvin Kwan Ho Kwok; Tai Fai Fok
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-01       Impact factor: 4.799

4.  Normal intraocular pressure in premature infants.

Authors:  A Spierer; R Huna; A Hirsh; A Chetrit
Journal:  Am J Ophthalmol       Date:  1994-06-15       Impact factor: 5.258

5.  Attempted eyelid closure affects intraocular pressure measurement.

Authors:  P D Gandhi; R Gürses-Ozden; J M Liebmann; R Ritch
Journal:  Am J Ophthalmol       Date:  2001-04       Impact factor: 5.258

6.  Is the tono-pen accurate for measuring intraocular pressure in young children with congenital glaucoma?

Authors:  Jaime Levy; Tova Lifshitz; Shirley Rosen; Zvi Tessler; Ben-Zion Biedner
Journal:  J AAPOS       Date:  2005-08       Impact factor: 1.220

7.  Distribution and determinants of intraocular pressure in a normal pediatric population.

Authors:  Ramanjit Sihota; Deven Tuli; Tanuj Dada; Viney Gupta; Murli Manohar Sachdeva
Journal:  J Pediatr Ophthalmol Strabismus       Date:  2006 Jan-Feb       Impact factor: 1.402

Review 8.  Glaucoma in children: are we making progress?

Authors:  Albert W Biglan
Journal:  J AAPOS       Date:  2006-02       Impact factor: 1.220

9.  Intraocular pressure in children up to five years of age.

Authors:  M Goethals; L Missotten
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1983 Mar-Apr       Impact factor: 1.402

10.  Normal intraocular pressure in children: a comparative study of the Perkins applanation tonometer and the pneumatonometer.

Authors:  M S Jaafar; G A Kazi
Journal:  J Pediatr Ophthalmol Strabismus       Date:  1993 Sep-Oct       Impact factor: 1.402

View more
  1 in total

1.  Normal intraocular pressure in Egyptian children and meta-analysis.

Authors:  Ibrahim Rezkallah Moussa; Rehab Rashad Kassem; Noha Ahmed Edris; Dalia Hamed Khalil
Journal:  Eye (Lond)       Date:  2021-06-18       Impact factor: 4.456

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.