Literature DB >> 28206930

Using Electromagnetic Navigation Bronchoscopy and Dye Injection to Aid in Video-Assisted Lung Resection.

Jordan Brown1, Thomas J Lee, Theresa Joiner, William Wrightson.   

Abstract

Small (2 cm) peripheral lung lesions and ground glass opacities remain a difficult subset of lung lesions for the diagnosis and management of lung cancer. Surgical biopsy is more difficult for these lesions because intraoperative localization has to be made without the aid of direct visualization or manual palpation. Electromagnetic navigation bronchoscopy can be used in the operating room to identify a small peripheral lesion and marked using an injection of methylene blue, which can be seen on the visceral pleura of the lung. We present our initial experience using this technique. The sample was eight patients who had peripheral lesions with an average size of 19 mm. Surgical wedge biopsy was diagnostic in all cases, with an average procedure time of 28 minutes. There were no complications from this procedure. In conclusion, these data suggest that electromagnetic navigation bronchoscopy can be performed safely with high diagnostic accuracy by the operating thoracic surgeon, but further data are needed to establish its utility and safety.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 28206930

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  4 in total

1.  Electromagnetic navigation bronchoscopic dye marking for localization of small subsolid nodules: Retrospective observational study.

Authors:  Kwanyong Hyun; In Kyu Park; Jae Won Song; Samina Park; Chang Hyun Kang; Young Tae Kim
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.817

2.  Uniportal VATS Coil-Assisted Resections for GGOs.

Authors:  Maria Teresa Congedo; Roberto Iezzi; Dania Nachira; Anna Rita Larici; Marco Chiappetta; Lucio Calandriello; Maria Letizia Vita; Elisa Meacci; Venanzio Porziella; Mahmoud Ismail; Riccardo Manfredi; Stefano Margaritora
Journal:  J Oncol       Date:  2019-05-12       Impact factor: 4.375

3.  [Feasibility of injecting Fluorescent Agent under the Guidance of Electromagnetic Navigation Bronchoscopy in Pulmonary Nodule Resection].

Authors:  Gongming Wang; Yongbin Lin; Kongjia Luo; Xiaodan Lin; Lanjun Zhang
Journal:  Zhongguo Fei Ai Za Zhi       Date:  2020-06-20

4.  Intraoperative localization in minimally invasive surgery for small pulmonary nodules: a retrospective study.

Authors:  Binjie Zhang; Yongkui Zhang; Hanbo Le; Wujun Li; Cheng Chen; Renxiu Fang; Xinfu Pan
Journal:  Transl Cancer Res       Date:  2021-07       Impact factor: 1.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.