Literature DB >> 28196034

Long-Term Results After Total Knee Arthroplasty with Contemporary Rotating-Hinge Prostheses.

Umberto Cottino1, Matthew P Abdel, Kevin I Perry, Kristin C Mara, David G Lewallen, Arlen D Hanssen.   

Abstract

BACKGROUND: Total knee arthroplasty (TKA) with a rotating-hinge prosthesis is considered a salvage procedure. While excellent immediate stability is achieved, the historically high failure rate has tempered its use. The goal of this study was to determine clinical outcomes, radiographic results, and survivorship after TKA with contemporary rotating-hinge components.
METHODS: We identified 408 consecutive TKAs performed with rotating-hinge components for nononcologic indications from 2002 to 2012 at a single academic institution. Two hundred and sixty-four knees (65%) had rotating-hinge TKA components implanted for aseptic etiologies, while 144 knees (35%) were managed with the components in 2-stage reimplantation following infection. Rotating-hinge TKA implants were used for complex primary procedures in 74 knees (18%) and as a revision construct in 334 knees (82%). Clinical outcomes were assessed with the Knee Society scoring system, survivorship analyses, and cumulative incidence of revision. The mean age of the patients at the time of the index arthroplasty was 69 years, and the mean duration of follow-up was 4 years (range, 2 to 12 years).
RESULTS: At the most recent follow-up, the mean Knee Society knee score had increased from 51 points preoperatively to 81 points (p < 0.0001), and the mean Knee Society functional score had increased from 26 to 36 points (p < 0.0001). At a mean of 4 years, loosening of components was observed in 13 (3.7%) of 349 knees. At the most recent follow-up, 59 revision procedures and 25 reoperations had been performed. The cumulative incidence of any revision was 9.7% at 2 years and 22.5% at 10 years. The cumulative incidence of revision for aseptic loosening was 1.7% at 2 years and 4.5% at 10 years. Metaphyseal cones were used in 114 knees (28%). Survivorship analysis revealed a trend toward a lower risk of revision (hazard ratio [HR] = 0.69; 95% confidence interval [CI] = 0.39 to 1.22; p = 0.20) and reoperation (HR = 0.51; 95% CI = 0.22 to 1.19; p = 0.12) in patients with metaphyseal cones, despite their use in the most severe of bone defects.
CONCLUSIONS: Contemporary rotating-hinge TKA implants had a low 10-year cumulative incidence of revision for aseptic loosening of 4.5%. Greater use of metaphyseal fixation has aided this improvement. Patients can expect substantial improvements in clinical outcomes with this revision strategy. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2017        PMID: 28196034     DOI: 10.2106/JBJS.16.00307

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  22 in total

1.  Metaphyseal cones and sleeves in revision total knee arthroplasty: Two sides of the same coin? Complications, clinical and radiological results-a systematic review of the literature.

Authors:  A Zanirato; M Formica; L Cavagnaro; S Divano; G Burastero; L Felli
Journal:  Musculoskelet Surg       Date:  2019-03-16

2.  CORR Insights®: Are Serum Metal Ion Levels a Concern at Mid-term Followup of Revision Knee Arthroplasty With a Metal-on-metal Hinge Design?

Authors:  Antti Eskelinen
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

3.  Risk factors for aseptic loosening in complex revision total knee arthroplasty using rotating hinge implants.

Authors:  Ali Levent; Eduardo M Suero; Thorsten Gehrke; Iman Godarzi Bakhtiari; Mustafa Citak
Journal:  Int Orthop       Date:  2020-11-14       Impact factor: 3.075

4.  Indications, clinical outcome and survival of rotating hinge total knee arthroplasty in a retrospective study of 63 primary and revision cases.

Authors:  Andreas Hecker; Hans-Jürg A Pütz; Sebastian Wangler; Sophie C Eberlein; Frank M Klenke
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-08-22

5.  Preoperative mechanical axis has no influence on reoperation rate in primary rotating-hinge knee arthroplasty.

Authors:  Oriol Pujol; Nayana Joshi-Jubert; Marta Altayó; Yuri Lara; Mercè Reverté-Vinaixa; Joan Pijoan; Enric Castellet; Joan Minguell
Journal:  J Orthop       Date:  2022-10-07

Review 6.  Rotating hinge prosthesis for complex revision total knee arthroplasty: A review of the literature.

Authors:  Shalen Kouk; Parthiv A Rathod; Aditya V Maheshwari; Ajit J Deshmukh
Journal:  J Clin Orthop Trauma       Date:  2017-12-05

7.  Options and limitations of implant constraint.

Authors:  S K S Marya; Chandeep Singh
Journal:  J Orthop       Date:  2020-12-23

8.  Finn/Orthopaedic Salvage System Distal Femoral Rotating-Hinge Megaprostheses in Oncologic Patients: Long-Term Complications, Reoperations, and Amputations.

Authors:  Koichi Ogura; Mohamed A Yakoub; Patrick J Boland; John H Healey
Journal:  J Bone Joint Surg Am       Date:  2021-04-21       Impact factor: 5.284

9.  What Is the Mid-term Survivorship of Infected Rotating-hinge Implants Treated with One-stage-exchange?

Authors:  Malte Ohlmeier; Fadi Alrustom; Mustafa Citak; Jochen Salber; Thorsten Gehrke; Jannik Frings
Journal:  Clin Orthop Relat Res       Date:  2021-12-01       Impact factor: 4.176

10.  Balance and constraint in revision TKR: A classification for instability management.

Authors:  Rhidian Morgan-Jones; Heiko Graichen
Journal:  J Orthop       Date:  2021-02-04
View more