| Literature DB >> 28194246 |
Mikolaj Wojtaszek1, Emilia Wnuk1, Rafal Maciag1, Bohdan Solonynko2, Krzysztof Korzeniowski1, Krzysztof Lamparski1, Olgierd Rowinski1.
Abstract
INTRODUCTION: Type 2 endoleaks (T2E) occur in 10 to 20% of patients after endovascular abdominal aortic aneurysm repair (EVAR) and remain a significant clinical issue. AIM: To evaluate the efficacy and clinical outcomes of transarterial treatment of persistent type II endoleaks after EVAR using the liquid embolic Onyx.Entities:
Keywords: Onyx copolymer; aortic aneurysm; endoleak; therapeutic embolization
Year: 2016 PMID: 28194246 PMCID: PMC5299085 DOI: 10.5114/wiitm.2016.64747
Source DB: PubMed Journal: Wideochir Inne Tech Maloinwazyjne ISSN: 1895-4588 Impact factor: 1.195
Patient demographics and comorbidities
| Parameter | Value |
|---|---|
| Age [years] | 73 ±9.1 |
| Male/female | 21/1 |
| Comorbidities, | |
| Cerebrovascular diseases | 6 (27.2) |
| Neoplasms | 3 (13.6) |
| Chronic renal failure | 3 (13.6) |
| Thyroid diseases | 2 (9) |
| Chronic obstructive pulmonary disease | 1 (4) |
| Cardiovascular risk factors, | |
| Hypertension | 14 (63) |
| Coronary artery disease | 12 (54) |
| Heart insufficiency | 5 (22.7) |
| Abnormal heart rhythms | 3 (13.6) |
| Dyslipidemia | 15 (68.1) |
| Diabetes mellitus | 5 (22.7) |
| Smoking habit | 16 (72.7) |
Photo 1A – Selective catheterization of the hypogastric-lumbar junction feeding an extensive type 2 endoleak supplied/drained by an additional pair of lumbar arteries, B – since the microcatheter could not be advanced further into the aneurysm sac, the copolymer Onyx was administered “from a distance” and penetrated throughout the endoleak cavity and filled the additional pair of lumbar arteries, C – confirmation angiogram showing successful treatment of the endoleak
Photo 2A – Selective catheterization of the SMA-middle colic-IMA collateral pathway (the arc of Riolan) and an angiogram performed showing an extensive endoleak draining into the left hypogastric artery, B – after initial coiling of the outflow vessel, Onyx was administered into the sac filling completely the endoleak cavity, C – confirmation angiogram showing successful treatment of the endoleak together with a fully patent superior rectal artery
Intraprocedural and follow-up results for transarterial embolization with data broken down in regards to the access route (N = 22)
| Variables | Access route for transarterial embolization | ||
|---|---|---|---|
| SMA/IMA | Hypogastric/lumbar | Hypogastric/hypogastric | |
|
| 9 | 11 | 2 |
| M/F | 9/0 | 10/1 | 2/0 |
| Onyx 34 | 8.7 ±9.4 | 5.6 ±4.8 | 1 ±1.4 |
| Onyx 18 | 0.6 ±1.4 | 1.09 ±1.5 | 2 ±1.4 |
| Onyx 18 and 34 | 9.4 ±9.1 | 6.7 ±4.0 | 3 |
| Additional outflow coil embolization | 3 (3, 3 and 4 coils) | 0 | 0 |
| Complete sac exclusion | 8 out of 9 | 8 out of 11 | 0 |
| Embolized outflow vessels 1 pair | 2 | 8 | 1 |
| Embolized outflow vessels 2 pair | 0 | 2 | 1 |
| Procedure time [min] | 107 | 92 | 61 |
| Fluoroscopy [min] | 67 | 49 | 37 |
| Technical success | 8/9 (88.9%) | 10/11 (90.9%) | 1/2 (50%) |
| Primary clinical success | |||
| (free from endoleak/no sac enlargement) | 6/9 (66.7%) | 9/10 (90%) (1 patient died before follow-up) | 2/2 (100%) |
| Subsequent intervention | DSP (2) | – | Iliac extension for late T3E (1) |
| Secondary clinical success | 8/9 (88.9%) | – | 2/2 (100%) |
| Follow-up, mean (range) [months] | 20 (3–38) | 16 (3–35) | 11 (8–14) |
SMA/IMA – superior mesenteric artery – inferior mesenteric artery collateral pathway, hypogastric/lumbar – hypogastric – lumbar artery collateral pathway, hypogastric/hypogastric – hypogastric – hypogastric collateral pathway used in the treatment of hypogastric aneurysms, DSP – direct sac puncture (translumbar puncture), T3E – type 3 endoleak.
Photo 3Follow-up CTA imaging. A – Wall thickening observed in two patients after Onyx embolization; Streak artifacts after Onyx embolization in some cases significantly impairing image readability, B – good image quality, C – average image quality, D – poor image quality. Statistical relation was found between the amount of Onyx used and the image quality