Literature DB >> 28193360

A review of rapid and field-portable analytical techniques for the diagnosis of cyanide exposure.

Randy Jackson1, Brian A Logue2.   

Abstract

Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Another relatively common, but consistently overlooked, mode of cyanide exposure is inhalation of fire smoke. Both civilians and fire rescue personnel risk exposure during the unfortunate event of a structure fire. Additionally, fire rescue personnel risk long-term effects of habitual exposure throughout their careers in fire rescue. The relatively rapid onset of cyanide toxicity and the fact that cyanide exposure symptoms mimic other medical conditions necessitate a rapid, sensitive, portable, and accurate method for the diagnosis of cyanide exposure. This review focuses on the important issues concerning accurate point-of-care diagnosis of cyanide exposure and cyanide detection technologies that may allow a commercial cyanide exposure diagnostic to become a reality.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioanalysis; Cyanide detection; Cyanide poisoning diagnosis; Sensor

Mesh:

Substances:

Year:  2017        PMID: 28193360     DOI: 10.1016/j.aca.2016.12.039

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  6 in total

1.  Mg-Al-CO3 layered double hydroxide reinforced polymer inclusion membrane as an extractant phase for thin-film microextraction of cyanide from environmental water samples.

Authors:  Maliheh Heidarbeigi; Mohammad Saraji; Mohammad Taghi Jafari
Journal:  Environ Sci Pollut Res Int       Date:  2019-07-24       Impact factor: 4.223

2.  Naked-Eye Chromogenic Test Strip for Cyanide Sensing Based on Novel Phenothiazine Push-Pull Derivatives.

Authors:  Pedro E Martín Várguez; Jean-Manuel Raimundo
Journal:  Biosensors (Basel)       Date:  2022-06-13

3.  Diagnosis of cyanide poisoning using an automated, field-portable sensor for rapid analysis of blood cyanide concentrations.

Authors:  Nesta Bortey-Sam; Randy Jackson; Obed A Gyamfi; Subrata Bhadra; Caleb Freeman; Sari B Mahon; Matthew Brenner; Gary A Rockwood; Brian A Logue
Journal:  Anal Chim Acta       Date:  2019-11-15       Impact factor: 6.558

4.  Origami paper analytical assay based on metal complex sensor for rapid determination of blood cyanide concentration in fire survivors.

Authors:  Azarmidokht Sheini; Marzieh Dadkhah Aseman; Mohammad Mahdi Bordbar
Journal:  Sci Rep       Date:  2021-02-10       Impact factor: 4.379

Review 5.  Recent Advances in Electrochemical Sensors for the Detection of Biomolecules and Whole Cells.

Authors:  Intan Rosalina Suhito; Kyeong-Mo Koo; Tae-Hyung Kim
Journal:  Biomedicines       Date:  2020-12-26

6.  [Determination of cyanogen chloride in organic and water matrices by gas chromatography-mass spectrometry based on thiol derivatization].

Authors:  Xiaosen Li; Jina Wu; Junmei Xia; Ling Yuan; Yang Yang
Journal:  Se Pu       Date:  2021-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.