Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.

Ruth Martis1, Ova Emilia2, Detty S Nurdiati2, Julie Brown1.   

Abstract

BACKGROUND: The goal of fetal monitoring in labour is the early detection of a hypoxic baby. There are a variety of tools and methods available for intermittent auscultation (IA) of the fetal heart rate (FHR). Low- and middle-income countries usually have only access to a Pinard/Laënnec or the use of a hand-held Doppler device. Currently, there is no robust evidence to guide clinical practice on the most effective IA tool to use, timing intervals and length of listening to the fetal heart for women during established labour.
OBJECTIVES: To evaluate the effectiveness of different tools for IA of the fetal heart rate during labour including frequency and duration of auscultation. SEARCH
METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (19 September 2016), contacted experts and searched reference lists of retrieved articles. SELECTION CRITERIA: All published and unpublished randomised controlled trials (RCTs) or cluster-RCTs comparing different tools and methods used for intermittent fetal auscultation during labour for fetal and maternal well-being. Quasi-RCTs, and cross-over designs were not eligible for inclusion. DATA COLLECTION AND ANALYSIS: All review authors independently assessed eligibility, extracted data and assessed risk of bias for each trial. Data were checked for accuracy. MAIN
RESULTS: We included three studies (6241 women and 6241 babies), but only two studies are included in the meta-analyses (3242 women and 3242 babies). Both were judged as high risk for performance bias due to the inability to blind the participants and healthcare providers to the interventions. Evidence was graded as moderate to very low quality; the main reasons for downgrading were study design limitations and imprecision of effect estimates. Intermittent Electronic Fetal Monitoring (EFM) using Cardiotocography (CTG) with routine Pinard (one trial)There was no clear difference between groups in low Apgar scores at five minutes (reported as < six at five minutes after birth) (risk ratio (RR) 0.66, 95% confidence interval (CI) 0.24 to 1.83, 633 babies, very low-quality evidence). There were no clear differences for perinatal mortality (RR 0.88, 95% CI 0.34 to 2.25; 633 infants, very low-quality evidence). Neonatal seizures were reduced in the EFM group (RR 0.05, 95% CI 0.00 to 0.89; 633 infants, very low-quality evidence). Other important infant outcomes were not reported: mortality or serious morbidity (composite outcome), cerebral palsy or neurosensory disability. For maternal outcomes, women allocated to intermittent electronic fetal monitoring (EFM) (CTG) had higher rates of caesarean section for fetal distress (RR 2.92, 95% CI 1.78 to 4.80, 633 women, moderate-quality evidence) compared with women allocated to routine Pinard. There was no clear difference between groups in instrumental vaginal births (RR 1.46, 95% CI 0.86 to 2.49, low-quality evidence). Other outcomes were not reported (maternal mortality, instrumental vaginal birth for fetal distress and or acidosis, analgesia in labour, mobility or restriction during labour, and postnatal depression). Doppler ultrasonography with routine Pinard (two trials)There was no clear difference between groups in Apgar scores < seven at five minutes after birth (reported as < six in one of the trials) (average RR 0.76, 95% CI 0.20 to 2.87; two trials, 2598 babies, I2 = 72%, very low-quality evidence); there was high heterogeneity for this outcome. There was no clear difference between groups for perinatal mortality (RR 0.69, 95% CI 0.09 to 5.40; 2597 infants, two studies, very low-quality evidence), or neonatal seizures (RR 0.05, 95% CI 0.00 to 0.91; 627 infants, one study, very low-quality evidence). Other important infant outcomes were not reported (cord blood acidosis, composite of mortality and serious morbidity, cerebral palsy, neurosensory disability). Only one study reported maternal outcomes. Women allocated to Doppler ultrasonography had higher rates of caesarean section for fetal distress compared with those allocated to routine Pinard (RR 2.71, 95% CI 1.64 to 4.48, 627 women, moderate-quality evidence). There was no clear difference in instrumental vaginal births between groups (RR 1.35, 95% CI 0.78 to 2.32, 627 women, low-quality evidence). Other maternal outcomes were not reported. Intensive Pinard versus routine Pinard (one trial)One trial compared intensive Pinard (a research midwife following the protocol in a one-to-one care situation) with routine Pinard (as per protocol but midwife may be caring for more than one woman in labour). There was no clear difference between groups in low Apgar score (reported as < six this trial) (RR 0.90, 95% CI 0.35 to 2.31, 625 babies, very low-quality evidence). There were also no clear differences identified for perinatal mortality (RR 0.56, 95% CI 0.19 to 1.67; 625 infants, very low-quality evidence), or neonatal seizures (RR 0.68, 95% CI 0.24 to 1.88, 625 infants, very low-quality evidence)). Other infant outcomes were not reported. For maternal outcomes, there were no clear differences between groups for caesarean section or instrumental delivery (RR 0.70, 95% CI 0.35 to 1.38, and RR 1.21, 95% CI 0.69 to 2.11, respectively, 625 women, both low-quality evidence)) Other outcomes were not reported. AUTHORS'
CONCLUSIONS: Using a hand-held (battery and wind-up) Doppler and intermittent CTG with an abdominal transducer without paper tracing for IA in labour was associated with an increase in caesarean sections due to fetal distress. There was no clear difference in neonatal outcomes (low Apgar scores at five minutes after birth, neonatal seizures or perinatal mortality). Long-term outcomes for the baby (including neurodevelopmental disability and cerebral palsy) were not reported. The quality of the evidence was assessed as moderate to very low and several important outcomes were not reported which means that uncertainty remains regarding the use of IA of FHR in labour.As intermittent CTG and Doppler were associated with higher rates of caesarean sections compared with routine Pinard monitoring, women, health practitioners and policy makers need to consider these results in the absence of evidence of short- and long-term benefits for the mother or baby.Large high-quality randomised trials, particularly in low-income settings, are needed. Trials should assess both short- and long-term health outcomes, comparing different monitoring tools and timing for IA.

Entities:  

Mesh:

Year:  2017        PMID: 28191626      PMCID: PMC6464556          DOI: 10.1002/14651858.CD008680.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  36 in total

1.  Intrauterine resuscitation: active management of fetal distress.

Authors:  J A Thurlow; S M Kinsella
Journal:  Int J Obstet Anesth       Date:  2002-04       Impact factor: 2.603

2.  FIGO consensus guidelines on intrapartum fetal monitoring: Intermittent auscultation.

Authors:  Debrah Lewis; Soo Downe
Journal:  Int J Gynaecol Obstet       Date:  2015-10       Impact factor: 3.561

3.  Developing a tool to appraise fetal monitoring guidelines for women at low obstetric risk.

Authors:  Carol Hindley; Sophie W Hinsliff; Ann M Thomson
Journal:  J Adv Nurs       Date:  2005-11       Impact factor: 3.187

4.  Emerging economies drive frugal innovation.

Authors: 
Journal:  Bull World Health Organ       Date:  2013-01-01       Impact factor: 9.408

5.  The history of monitoring the human fetus.

Authors:  B Gültekin-Zootzmann
Journal:  J Perinat Med       Date:  1975       Impact factor: 1.901

Review 6.  Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing.

Authors:  Declan Devane; Joan G Lalor; Sean Daly; William McGuire; Valerie Smith
Journal:  Cochrane Database Syst Rev       Date:  2012-02-15

7.  Intermittent auscultation of the fetal heart rate: a review of general principles.

Authors:  L Goodwin
Journal:  J Perinat Neonatal Nurs       Date:  2000-12       Impact factor: 1.638

8.  Association of cerebral palsy with Apgar score in low and normal birthweight infants: population based cohort study.

Authors:  Kari Kveim Lie; Else-Karin Grøholt; Anne Eskild
Journal:  BMJ       Date:  2010-10-06

Review 9.  Fetal pulse oximetry for fetal assessment in labour.

Authors:  Christine E East; Lisa Begg; Paul B Colditz; Rosalind Lau
Journal:  Cochrane Database Syst Rev       Date:  2014-10-07

Review 10.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

Authors:  Zarko Alfirevic; Declan Devane; Gillian M L Gyte
Journal:  Cochrane Database Syst Rev       Date:  2013-05-31
View more
  9 in total

1.  Effectiveness of a Novel Continuous Doppler (Moyo) Versus Intermittent Doppler in Intrapartum Detection of Abnormal Foetal Heart Rate: A Randomised Controlled Study in Tanzania.

Authors:  Benjamin Kamala; Hussein Kidanto; Ingvild Dalen; Matilda Ngarina; Muzdalifat Abeid; Jeffrey Perlman; Hege Ersdal
Journal:  Int J Environ Res Public Health       Date:  2019-01-24       Impact factor: 3.390

2.  Systematic review of Doppler for detecting intrapartum fetal heart abnormalities and measuring perinatal mortality in low- and middle-income countries.

Authors:  Marya Plotkin; Benjamin Kamala; Jim Ricca; Linda Fogarty; Sheena Currie; Hussein Kidanto; Stephanie B Wheeler
Journal:  Int J Gynaecol Obstet       Date:  2019-12-05       Impact factor: 3.561

3.  Disclosing suboptimal indications for emergency caesarean sections due to fetal distress and prolonged labor: a multicenter cross-sectional study at 12 public hospitals in Nepal.

Authors:  Helena Litorp; Rejina Gurung; Mats Målqvist; Ashish Kc
Journal:  Reprod Health       Date:  2020-12-17       Impact factor: 3.223

Review 4.  Intermittent auscultation (IA) of fetal heart rate in labour for fetal well-being.

Authors:  Ruth Martis; Ova Emilia; Detty S Nurdiati; Julie Brown
Journal:  Cochrane Database Syst Rev       Date:  2017-02-13

5.  Intrapartum Fetal Heart Monitoring Practices in Selected Facilities in Aspirational Districts of Jharkhand, Odisha and Uttarakhand.

Authors:  Enisha Sarin; Devina Bajpayee; Arvind Kumar; Sourav Ghosh Dastidar; Subodh Chandra; Ranjan Panda; Gunjan Taneja; Sachin Gupta; Harish Kumar
Journal:  J Obstet Gynaecol India       Date:  2021-01-17

Review 6.  A review of fetal cardiac monitoring, with a focus on low- and middle-income countries.

Authors:  Camilo E Valderrama; Nasim Ketabi; Faezeh Marzbanrad; Peter Rohloff; Gari D Clifford
Journal:  Physiol Meas       Date:  2020-12-18       Impact factor: 2.688

7.  Intrapartum fetal heart rate monitoring using a handheld Doppler versus Pinard stethoscope: a randomized controlled study in Dar es Salaam.

Authors:  Benjamin A Kamala; Hussen L Kidanto; Peter J Wangwe; Ingvild Dalen; Estomih R Mduma; Jeffrey M Perlman; Hege L Ersdal
Journal:  Int J Womens Health       Date:  2018-07-09

8.  Implementation of a novel continuous fetal Doppler (Moyo) improves quality of intrapartum fetal heart rate monitoring in a resource-limited tertiary hospital in Tanzania: An observational study.

Authors:  Benjamin A Kamala; Hege L Ersdal; Ingvild Dalen; Muzdalifat S Abeid; Matilda M Ngarina; Jeffrey M Perlman; Hussein L Kidanto
Journal:  PLoS One       Date:  2018-10-11       Impact factor: 3.240

9.  Strategies for intrapartum foetal surveillance in low- and middle-income countries: A systematic review.

Authors:  Natasha Housseine; Marieke C Punt; Joyce L Browne; Tarek Meguid; Kerstin Klipstein-Grobusch; Barbara E Kwast; Arie Franx; Diederick E Grobbee; Marcus J Rijken
Journal:  PLoS One       Date:  2018-10-26       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.