| Literature DB >> 28174464 |
Yuki Fukumoto1, Yoshibumi Bunno1, Toshiaki Suzuki1.
Abstract
[Purpose] This study aimed to examine the effect of motor imagery on the accuracy of motion and the excitability of spinal neural function.Entities:
Keywords: Accurate control of muscle force; F-waves; Motor imagery
Year: 2016 PMID: 28174464 PMCID: PMC5276773 DOI: 10.1589/jpts.28.3416
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Fig. 1.The experimental process. In the resting condition and holding sensor condition, we recorded F-waves. Next, the subjects learned 50% MVC during isometric contraction of the opponents pollicis muscle. Subsequently, we measured pinch force without using visual feedback before and after motor imagery. Additionally, F-waves were recorded during the motor imagery.
Fig. 2.The F-wave testing conditions. F-waves were analyzed with respect to persistence, F/M amplitude ratio, and latency.
Fig. 3.The index of accurate control of muscle force. We studied that exerted apposite and sustained force of pinch action by the correction time (the total time of the pinch force of 50%MVC ± 5%) and coefficient of variation.
Changes in the F-wave during MVC50% (MI group)
| Rest | Holding sensor | MI | |
|---|---|---|---|
| Persistence (%) | 63.4 ± 22.7 | 78.1 ± 17.2* | 90.5 ± 9.6**# |
| F/M amplitude ratio (%) | 1.2 ± 0.6 | 1.8 ± 0.8* | 2.2 ± 1.5** |
| Latency (ms) | 23.5 ± 1.7 | 23.4 ± 1.7 | 23.2 ± 2.0 |
Mean ± SD. *significant (p<0.05), **significant (p<0.01) vs. at rest. #significant (p<0.05) vs. with sensor.
MI: motor imagery
Changes in the F-wave during MVC50% (without MI group)
| Rest | Holding sensor | Without MI | |
|---|---|---|---|
| Persistence (%) | 47.4 ± 19.1 | 72.1 ± 16.5** | 67.5 ± 17.6* |
| F/M amplitude ratio (%) | 1.2 ± 0.5 | 1.9 ± 1.1* | 1.8 ± 1.1** |
| Latency (ms) | 23.9 ± 1.7 | 23.5 ± 1.7 | 23.5 ± 1.8 |
Mean ± SD. *significant (p<0.05), ** significant(p<0.01) vs. at rest. MI: motor imagery
Changes in the accurate control of muscle force (MI group)
| Task 1 | Task 2 | |
|---|---|---|
| Correction time (s) | 1.2 ± 1.5 | 0.7 ± 1.6 |
| Coefficient of variation | 0.1 ± 0.1 | 0.1 ± 0.1 |
Changes in the accurate control of muscle force (without MI group)
| Task 1 | Task 2 | |
|---|---|---|
| Correction time (s) | 1.2 ± 1.7 | 0.7 ± 1.2 |
| Coefficient of variation | 0.1 ± 0.1 | 0.1 ± 0.1 |