Literature DB >> 28165334

Sensitivity of simulated transcranial ultrasound fields to acoustic medium property maps.

James Robertson1, Eleanor Martin, Ben Cox, Bradley E Treeby.   

Abstract

High intensity transcranial focused ultrasound is an FDA approved treatment for essential tremor, while low-intensity applications such as neurostimulation and opening the blood brain barrier are under active research. Simulations of transcranial ultrasound propagation are used both for focusing through the skull, and predicting intracranial fields. Maps of the skull acoustic properties are necessary for accurate simulations, and can be derived from medical images using a variety of methods. The skull maps range from segmented, homogeneous models, to fully heterogeneous models derived from medical image intensity. In the present work, the impact of uncertainties in the skull properties is examined using a model of transcranial propagation from a single element focused transducer. The impact of changes in bone layer geometry and the sound speed, density, and acoustic absorption values is quantified through a numerical sensitivity analysis. Sound speed is shown to be the most influential acoustic property, and must be defined with less than 4% error to obtain acceptable accuracy in simulated focus pressure, position, and volume. Changes in the skull thickness of as little as 0.1 mm can cause an error in peak intracranial pressure of greater than 5%, while smoothing with a 1 [Formula: see text] kernel to imitate the effect of obtaining skull maps from low resolution images causes an increase of over 50% in peak pressure. The numerical results are confirmed experimentally through comparison with sonications made through 3D printed and resin cast skull bone phantoms.

Entities:  

Mesh:

Year:  2017        PMID: 28165334     DOI: 10.1088/1361-6560/aa5e98

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Multi-resolution simulation of focused ultrasound propagation through ovine skull from a single-element transducer.

Authors:  Kyungho Yoon; Wonhye Lee; Phillip Croce; Amanda Cammalleri; Seung-Schik Yoo
Journal:  Phys Med Biol       Date:  2018-05-10       Impact factor: 3.609

3.  Acoustic-based proton range verification in heterogeneous tissue: simulation studies.

Authors:  Kevin C Jones; Wei Nie; James C H Chu; Julius V Turian; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

4.  Systematic examination of low-intensity ultrasound parameters on human motor cortex excitability and behavior.

Authors:  Anton Fomenko; Kai-Hsiang Stanley Chen; Jean-François Nankoo; James Saravanamuttu; Yanqiu Wang; Mazen El-Baba; Xue Xia; Shakthi Sanjana Seerala; Kullervo Hynynen; Andres M Lozano; Robert Chen
Journal:  Elife       Date:  2020-11-25       Impact factor: 8.140

5.  Effects of phase aberration on transabdominal focusing for a large aperture, lowf-number histotripsy transducer.

Authors:  Ellen Yeats; Dinank Gupta; Zhen Xu; Timothy L Hall
Journal:  Phys Med Biol       Date:  2022-07-19       Impact factor: 4.174

6.  Radiomics-Informed Modeling for Transcranial Ultrasound Stimulation: Age Matters.

Authors:  Hanna Lu
Journal:  Front Neurosci       Date:  2022-06-15       Impact factor: 5.152

7.  Pressure Pulse Distortion by Needle and Fiber-Optic Hydrophones due to Nonuniform Sensitivity.

Authors:  Keith A Wear; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-02       Impact factor: 2.725

8.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Needle Hydrophones: Predictions From Four Theoretical Forms Compared With Measurements.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-13       Impact factor: 2.725

9.  Measurements of the Relationship Between CT Hounsfield Units and Acoustic Velocity and How It Changes With Photon Energy and Reconstruction Method.

Authors:  Taylor D Webb; Steven A Leung; Jarrett Rosenberg; Pejman Ghanouni; Jeremy J Dahl; Norbert J Pelc; Kim Butts Pauly
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

10.  A rapid beam simulation framework for transcranial focused ultrasound.

Authors:  Steven A Leung; Taylor D Webb; Rachelle R Bitton; Pejman Ghanouni; Kim Butts Pauly
Journal:  Sci Rep       Date:  2019-05-28       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.