| Literature DB >> 2816236 |
O A Meretoja1, M U Werner, K Wirtavuori, T Luosto.
Abstract
We compared thumb acceleration (Acc) and thenar electromyography (EMG) techniques by evaluating the neuromuscular blocking properties of alcuronium in 14 ASA physical status I patients. The dose-response curves determined by the two techniques were parallel but the EMG-curve was shifted 25% to the right (P less than 0.001). Acc reflected 8-11% greater neuromuscular block than simultaneous EMG in every patients (P less than 0.05). Concurrently, the duration of greater than 90% neuromuscular block maintained by alcuronium 280 micrograms/kg was significantly longer when measured by the Acc transducer (30 vs. 19 min, P less than 0.001). Although the TOF ratios were in good correlation (r2 = 0.82), clinically significant differences existed between the two simultaneous techniques. The results underline the importance of the method of assessment of neuromuscular transmission when evaluating the action of neuromuscular blocking drugs.Entities:
Mesh:
Substances:
Year: 1989 PMID: 2816236 DOI: 10.1111/j.1399-6576.1989.tb02963.x
Source DB: PubMed Journal: Acta Anaesthesiol Scand ISSN: 0001-5172 Impact factor: 2.105