Literature DB >> 28159679

Is there a role for femoral offset restoration during total hip arthroplasty? A systematic review.

M De Fine1, M Romagnoli2, A Toscano2, A Bondi2, M Nanni2, S Zaffagnini2.   

Abstract

Benefits of femoral offset restoration during total hip arthroplasty should be the reduction of bearing surfaces wear, implant loosening and dislocation rates. Modular neck stems ensure offset customization but fretting corrosion and catastrophic failures are well-documented complications. Since clinical evidences are needed to substantiate the effectiveness of femoral offset restoration and promote modular neck choice, we systematically reviewed the literature to ascertain whether femoral offset itself has a proven clinical influence: (1) on bearing surfaces wear, (2) implant loosening, (3) and dislocation rates. A systematic literature screening was conducted to find papers dealing with the influence of femoral offset on wear, dislocation and loosening, including articles with conventional radiographic femoral offset assessment and with comparative design. Observational studies, case reports, instructional course lectures, cadaveric and animal studies as well as biomechanical studies, letters to the editor, surgical techniques or technical notes were all excluded. No limits about publication date were supplied but only papers in English were taken into account. Data were extracted into an anonymous spreadsheet. Offset values, dislocation rates, wear rates, follow-up and surgical approaches were all detailed. Ten manuscripts were finally selected. A statistically significant correlation between femoral offset restoration and the reduction of conventional ultrahigh-molecular-weight polyethylene wear was found in two out of three papers investigating this issue, but no correlations were found between femoral offset and dislocation rates or implant loosening. Femoral offset modification influences ultrahigh-molecular-weight polyethylene liners wear, but no correlation was found with dislocation rates or implant loosening. Advantages on wear can be counterbalanced by the use of hard bearing surfaces or highly cross-linked polyethylene liners, besides the availability of larger femoral heads improving implant stability further reduces the importance of femoral offset restoration by means of modularity. We believe that efforts in restoring femoral offset during total hip arthroplasty do not translate into tangible clinical profits and consequently, we do not advise the routinely usage of modular neck stems in total hip arthroplasty. LEVEL OF EVIDENCE: level III, systematic review of case-control studies.
Copyright © 2017 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Dislocation; Femoral Offset; Loosening; Total hip arthroplasty; Wear

Mesh:

Substances:

Year:  2017        PMID: 28159679     DOI: 10.1016/j.otsr.2016.12.013

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  12 in total

1.  Outcomes of neck modularity in total hip arthroplasty: an Italian perspective.

Authors:  R Papalia; A Di Martino; A Caldaria; B Zampogna; V Denaro
Journal:  Musculoskelet Surg       Date:  2019-01-23

2.  A study of femoral offset in the South Indian population and its clinical implications in hip arthroplasty.

Authors:  Gautam Kumar; Mohamed Jisam; Jacob Varghese; Julio C Kandathil; Bipin Theruvil
Journal:  J Clin Orthop Trauma       Date:  2021-10-04

3.  Pre- and postoperative offset and femoral neck version measurements and validation using 3D computed tomography in total hip arthroplasty.

Authors:  Mats Geijer; Sverrir Kiernan; Martin Sundberg; Gunnar Flivik
Journal:  Acta Radiol Open       Date:  2020-10-08

4.  Conventional computed tomography software can be used for accurate pre-operative templating in bipolar hip arthroplasty: A preliminary report.

Authors:  Nobuaki Chinzei; Mitsuaki Noda; Hiroshi Nashiki; Takehiko Matsushita; Atsuyuki Inui; Shinya Hayashi
Journal:  J Clin Orthop Trauma       Date:  2020-09-06

Review 5.  The role of the femoral component orientation on dislocations in THA: a systematic review.

Authors:  Joost H J van Erp; Thom E Snijders; Harrie Weinans; René M Castelein; Tom P C Schlösser; Arthur de Gast
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-08       Impact factor: 2.928

6.  Geometrical restoration during total hip arthroplasty is related to change in gait pattern - a study based on computed tomography and three-dimensional gait analysis.

Authors:  A-C Esbjörnsson; S Kiernan; L Mattsson; G Flivik
Journal:  BMC Musculoskelet Disord       Date:  2021-04-20       Impact factor: 2.362

7.  The trochanteric double contour is a valuable landmark for assessing femoral offset underestimation on standard radiographs: a retrospective study.

Authors:  Stefan Blümel; Vincent A Stadelmann; Marco Brioschi; Alexander Küffer; Michael Leunig; Hannes A Rüdiger
Journal:  BMC Musculoskelet Disord       Date:  2021-03-29       Impact factor: 2.362

8.  Relationships between Femoral Offset Change and Clinical Score following Bipolar Hip Arthroplasty in Femoral Neck Fractures.

Authors:  Sung Soo Kim; Hyeon Jun Kim; Chang Heon Shim
Journal:  Hip Pelvis       Date:  2021-06-04

9.  The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length.

Authors:  Maliha Fansur; Nagib A Yurdi; Reinhard Stoewe
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

10.  Midterm outcomes of titanium modular femoral necks in total hip arthroplasty.

Authors:  Thurial Collet; Jean-Pierre Atanasiu; Jean-Baptiste de Cussac; Kamal Oufroukhi; Hugo Bothorel; Mo Saffarini; François Badatcheff
Journal:  Ann Transl Med       Date:  2017-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.