Literature DB >> 28152631

Construction of an in vivo carotid siphon model for testing endovascular devices for neuro-interventions.

Bu-Lang Gao1, Yong-Li Wang2, Xue-Jing Zhang1, Qiong-Ying Fan1, Wei-Li Hao1, Dong-Hai Zhang3.   

Abstract

Objective The aim of this study was to construct an in vivo carotid siphon model for testing neurovascular devices for endovascular interventions. Methods A model of a human carotid siphon was pre-shaped using a glass tube from a human cadaver and used to confine a segment of one side of the common carotid artery (CCA) in canines. This segment of CCA with the glass carotid siphon on was interposed end-to-end onto the contralateral CCA so as to simulate a human carotid artery siphon in vivo. Two weeks later, the siphon model was evaluated using computed tomography angiography and digital subtraction angiography, and the covered stent specially designed for intracranial vasculature was navigated through the siphon model for a longitudinal flexibility test. Results All dogs tolerated the procedures well, and the artificial siphon model in vivo provided realistic conditions for device testing. Two weeks later, the in vivo carotid siphon model remained patent with no thrombosis. Five covered stents were navigated to pass through five siphon models successfully, with vasospasm occurring in two siphons. Conclusion Construction of an in vivo siphon model in dogs with a glass tube is feasible and useful for the test of endovascular devices for treating neurovascular diseases.

Entities:  

Keywords:  In vivo; animal experiment; canine; carotid siphon model; endovascular device

Mesh:

Year:  2017        PMID: 28152631      PMCID: PMC5490852          DOI: 10.1177/1591019916688649

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  9 in total

1.  [Angiography of the cervico-cephalic vessels of the dog. The carotid system].

Authors:  F Jung; R Beysang; L Guceve; P Kehr
Journal:  J Chir (Paris)       Date:  1975-01

2.  Surgical construction of an in vivo carotid siphon model to test neurovascular devices.

Authors:  Stavros A Georganos; François Guilbert; Igor Salazkin; Guylaine Gévry; Jean Raymond
Journal:  Neurosurgery       Date:  2004-05       Impact factor: 4.654

3.  Experimental functional analysis of self-expanding stents using a new developed ex vivo model.

Authors:  Lars Grenacher; Ellen Gänger; Andreas Lubienski; Markus Düx; Gunter W Kauffmann; Götz M Richter
Journal:  Invest Radiol       Date:  2004-06       Impact factor: 6.016

4.  Determinants of stent expansion in curved stenotic lesions: an in vitro experimental study.

Authors:  Tudor C Poerner; Bettina Ludwig; Stephan H Duda; Peter Diesing; Gábor Kalmár; Tim Süselbeck; Jens J Kaden; Martin Borggrefe; Karl K Haase
Journal:  J Vasc Interv Radiol       Date:  2004-07       Impact factor: 3.464

5.  Management of pseudoaneurysms in the intracranial segment of the internal carotid artery with covered stents specially designed for use in the intracranial vasculature: technical notes.

Authors:  Ming-Hua Li; Bu-Lang Gao; Yong-Li Wang; Chun Fang; Yong-Dong Li
Journal:  Neuroradiology       Date:  2006-08-31       Impact factor: 2.804

6.  In vitro studies of the neuroform microstent using transparent human intracranial arteries.

Authors:  S-W Hsu; J C Chaloupka; J A Feekes; M D Cassell; Y-F Cheng
Journal:  AJNR Am J Neuroradiol       Date:  2006-05       Impact factor: 3.825

7.  Conformability of balloon-expandable stents to the carotid siphon: an in vitro study.

Authors:  R du Mesnil de Rochemont; B Yan; F E Zanella; D A Rüfenacht; J Berkefeld
Journal:  AJNR Am J Neuroradiol       Date:  2006-02       Impact factor: 3.825

8.  Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.

Authors:  Eberhard C Kirsch; Mark S Khangure; Philip Morling; Terry J York; William McAuliffe
Journal:  AJNR Am J Neuroradiol       Date:  2002-01       Impact factor: 3.825

9.  Measurement of flow modification in phantom aneurysm model: comparison of coils and a longitudinally and axially asymmetric stent--initial findings.

Authors:  Stephen Rudin; Zhou Wang; Iacovos Kyprianou; Kenneth R Hoffmann; Ye Wu; Hui Meng; Lee R Guterman; Balazs Nemes; Daniel R Bednarek; Jacek Dmochowski; L Nelson Hopkins
Journal:  Radiology       Date:  2004-04       Impact factor: 11.105

  9 in total
  2 in total

1.  Tandem Short-length Multi-stent Construct for Emergent Revascularization of Occlusive Long-segment Left Middle Cerebral Artery In-stent Stenosis.

Authors:  Torin W Karsonovich; Brittany R Bolt; Ajeet Gordhan
Journal:  Cureus       Date:  2020-04-15

2.  Application of nondestructive mechanical characterization testing for creating in vitro vessel models with material properties similar to human neurovasculature.

Authors:  Nicholas G Norris; William C Merritt; Timothy A Becker
Journal:  J Biomed Mater Res A       Date:  2021-10-06       Impact factor: 4.854

  2 in total