| Literature DB >> 28144536 |
Niina Halonen1, Joni Kilpijärvi1, Maciej Sobocinski1, Timir Datta-Chaudhuri2, Antti Hassinen3, Someshekar B Prakash4, Peter Möller5, Pamela Abshire2, Sakari Kellokumpu3, Anita Lloyd Spetz6.
Abstract
Cell viability monitoring is an important part of biosafety evaluation for the detection of toxic effects on cells caused by nanomaterials, preferably by label-free, noninvasive, fast, and cost effective methods. These requirements can be met by monitoring cell viability with a capacitance-sensing integrated circuit (IC) microchip. The capacitance provides a measurement of the surface attachment of adherent cells as an indication of their health status. However, the moist, warm, and corrosive biological environment requires reliable packaging of the sensor chip. In this work, a second generation of low temperature co-fired ceramic (LTCC) technology was combined with flip-chip bonding to provide a durable package compatible with cell culture. The LTCC-packaged sensor chip was integrated with a printed circuit board, data acquisition device, and measurement-controlling software. The packaged sensor chip functioned well in the presence of cell medium and cells, with output voltages depending on the medium above the capacitors. Moreover, the manufacturing of microfluidic channels in the LTCC package was demonstrated.Entities:
Keywords: capacitance sensing; cell viability; lab-on-a-chip; low temperature co-fired ceramic (LTCC)
Year: 2016 PMID: 28144536 PMCID: PMC5238666 DOI: 10.3762/bjnano.7.179
Source DB: PubMed Journal: Beilstein J Nanotechnol ISSN: 2190-4286 Impact factor: 3.649
Figure 1(a) Layout of the dummy chip mimicking the size of the sensor chip and the contact pad positions and sizes. (b) Microscope image of the capacitance sensor chip showing contact pads at the periphery and an array of sensors distributed over 16 rows and 5 columns. (c) Close up of capacitive finger electrode structures.
Figure 2Schematic image of the isotropic conductive adhesive stamping process, sensor chip mounting, and underfill application.
Figure 3(a) Bottom side of the LTCC package showing the rear side of the sensor chip. (b) The sensor chip in the LTCC package connected. The active side of the chip is inside the cell culture vial glued on the top of the LTCC package. (c) Prototype of the package with integrated microfluidic channel.
Figure 4The total resistance of an LTCC packaged dummy chip placed in a cell culture incubator before and after cell growth media and BEAS2B cells were added onto the chip.
Figure 5Normally proliferating BEAS2B cells on a dummy chip in LTCC package. (a–c) the cells grow on top of the chip. (d–f) The cells grow on top of LTCC. In (a) and (d), the blue color indicates the cell nuclei stained with a DNA binding dye, Hoechst 33342. In (b) and (e), immunofluorescence staining was performed with anti-α-tubulin antibody and Alexa 488 secondary antibody. The green color shows the microtubules of the cell cytoskeleton. In (c) and (f), the merged image of the nuclear staining and cytoskeleton are shown. The images were taken with a Zeiss LSM700 confocal microscope with 63× plan-apo immersion objective and appropriate filter sets.
Figure 6Average voltage change from the baseline over time from all sensors on one chip after cell media and cells were added. The average signal from the sensors on the dry chip is added for comparison.