Literature DB >> 24682025

Packaging commercial CMOS chips for lab on a chip integration.

Timir Datta-Chaudhuri1, Pamela Abshire, Elisabeth Smela.   

Abstract

Combining integrated circuitry with microfluidics enables lab-on-a-chip (LOC) devices to perform sensing, freeing them from benchtop equipment. However, this integration is challenging with small chips, as is briefly reviewed with reference to key metrics for package comparison. In this paper we present a simple packaging method for including mm-sized, foundry-fabricated dies containing complementary metal oxide semiconductor (CMOS) circuits within LOCs. The chip is embedded in an epoxy handle wafer to yield a level, large-area surface, allowing subsequent photolithographic post-processing and microfluidic integration. Electrical connection off-chip is provided by thin film metal traces passivated with parylene-C. The parylene is patterned to selectively expose the active sensing area of the chip, allowing direct interaction with a fluidic environment. The method accommodates any die size and automatically levels the die and handle wafer surfaces. Functionality was demonstrated by packaging two different types of CMOS sensor ICs, a bioamplifier chip with an array of surface electrodes connected to internal amplifiers for recording extracellular electrical signals and a capacitance sensor chip for monitoring cell adhesion and viability. Cells were cultured on the surface of both types of chips, and data were acquired using a PC. Long term culture (weeks) showed the packaging materials to be biocompatible. Package lifetime was demonstrated by exposure to fluids over a longer duration (months), and the package was robust enough to allow repeated sterilization and re-use. The ease of fabrication and good performance of this packaging method should allow wide adoption, thereby spurring advances in miniaturized sensing systems.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24682025     DOI: 10.1039/c4lc00135d

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  9 in total

1.  Nano-plasmonics and electronics co-integration in CMOS enabling a pill-sized multiplexed fluorescence microarray system.

Authors:  Lingyu Hong; Hao Li; Haw Yang; Kaushik Sengupta
Journal:  Biomed Opt Express       Date:  2018-10-26       Impact factor: 3.732

2.  Epoxy Chip-in-Carrier Integration and Screen-Printed Metalization for Multichannel Microfluidic Lab-on-CMOS Microsystems.

Authors:  Lin Li; Heyu Yin; Andrew J Mason
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2018-04       Impact factor: 3.833

3.  A multi-scale PDMS fabrication strategy to bridge the size mismatch between integrated circuits and microfluidics.

Authors:  Melaku Muluneh; David Issadore
Journal:  Lab Chip       Date:  2014-10-06       Impact factor: 6.799

4.  Closed-loop neuromodulation will increase the utility of mouse models in Bioelectronic Medicine.

Authors:  Timir Datta-Chaudhuri
Journal:  Bioelectron Med       Date:  2021-06-30

Review 5.  CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review.

Authors:  Haitao Li; Xiaowen Liu; Lin Li; Xiaoyi Mu; Roman Genov; Andrew J Mason
Journal:  Sensors (Basel)       Date:  2016-12-31       Impact factor: 3.576

6.  Low temperature co-fired ceramic packaging of CMOS capacitive sensor chip towards cell viability monitoring.

Authors:  Niina Halonen; Joni Kilpijärvi; Maciej Sobocinski; Timir Datta-Chaudhuri; Antti Hassinen; Someshekar B Prakash; Peter Möller; Pamela Abshire; Sakari Kellokumpu; Anita Lloyd Spetz
Journal:  Beilstein J Nanotechnol       Date:  2016-11-29       Impact factor: 3.649

7.  3D Stretchable Arch Ribbon Array Fabricated via Grayscale Lithography.

Authors:  Yu Pang; Yi Shu; Mohammad Shavezipur; Xuefeng Wang; Mohammad Ali Mohammad; Yi Yang; Haiming Zhao; Ningqin Deng; Roya Maboudian; Tian-Ling Ren
Journal:  Sci Rep       Date:  2016-06-27       Impact factor: 4.379

Review 8.  Silicon Photonic Biosensors Using Label-Free Detection.

Authors:  Enxiao Luan; Hossam Shoman; Daniel M Ratner; Karen C Cheung; Lukas Chrostowski
Journal:  Sensors (Basel)       Date:  2018-10-18       Impact factor: 3.576

9.  LTCC Packaged Ring Oscillator Based Sensor for Evaluation of Cell Proliferation.

Authors:  Joni Kilpijärvi; Niina Halonen; Maciej Sobocinski; Antti Hassinen; Bathiya Senevirathna; Kajsa Uvdal; Pamela Abshire; Elisabeth Smela; Sakari Kellokumpu; Jari Juuti; Anita Lloyd Spetz
Journal:  Sensors (Basel)       Date:  2018-10-07       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.