Modeling dental implant insertion.

A Dorogoy1, D Rittel2, K Shemtov-Yona1, R Korabi1.   

Abstract

The success of dental implantation is connected with the so-called implant primary stability, a synonym for the implant anchoring inside the bone. The primary stability is related to the applied peak torque to the implant during the insertion process. This work simulates the process of insertion of a typical commercial implant into the jaw bone (mandible) using a 3D dynamic non-linear finite-elements software. The model considers the geometrical and mechanical properties of the implant, the bone-implant friction, and the insertion procedure parameters, namely angular velocity and normal load. The numerical results assess the influence of those parameters on the evolution of the insertion torque and the resulting bone damage. It is found that, within the model's assumptions, the angular insertion velocity (up to 120rpm) has little or no effect on the process. The application of a normal load, in addition to the implant rotation, enforces an extrusion process in addition to the screwing one. The respective contribution of the cortical and trabecular bone components to the insertion torque reveals that, despite its significantly lower strength, the trabecular bone has a definite contribution to the insertion process. This work shows that if the various physical, geometrical and mechanical parameters of the bone-implant system are well-defined, the insertion process can be simulated prior to the surgical act, and predict, tailor and contribute to maximize the success of dental implantation in a personalized manner.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Keywords:  Bone damage; Dental implants; Insertion torque; Numerical model; Primary stability

Mesh:

Substances:

Year:  2017        PMID: 28142072     DOI: 10.1016/j.jmbbm.2017.01.021

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  5 in total

1.  Dental implant primary stability in different regions of the Jawbone: CBCT-based 3D finite element analysis.

Authors:  Razan Alaqeely; Nadir Babay; Montaser AlQutub
Journal:  Saudi Dent J       Date:  2019-06-17

2.  Biomechanics of Immediate Postextraction Implant Osseointegration.

Authors:  X Yuan; X Pei; Y Zhao; Z Li; C H Chen; U S Tulu; B Liu; L A Van Brunt; J B Brunski; J A Helms
Journal:  J Dent Res       Date:  2018-04-02       Impact factor: 6.116

3.  Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability.

Authors:  Tanja Grobecker-Karl; Anthony Dickinson; Siegfried Heckmann; Matthias Karl; Constanze Steiner
Journal:  J Clin Med       Date:  2020-09-15       Impact factor: 4.241

4.  The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis.

Authors:  Zhi-Heng Jin; Meng-Dong Peng; Qing Li
Journal:  J Dent Sci       Date:  2019-12-31       Impact factor: 2.080

5.  Does intraoperative bone density testing correlate with parameters of primary implant stability? A pilot study in minipigs.

Authors:  Tanja Grobecker-Karl; Victor Palarie; Sonja Schneider; Matthias Karl
Journal:  Clin Exp Dent Res       Date:  2019-09-30
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.