Radiation dose-reduction strategies in thoracic CT.

J B Moser1, S L Sheard2, S Edyvean3, I Vlahos2.   

Abstract

Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure.
Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28139204     DOI: 10.1016/j.crad.2016.11.021

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  9 in total

1.  Radiation burden and associated cancer risk for a typical population to be screened for lung cancer with low-dose CT: A phantom study.

Authors:  Kostas Perisinakis; Ioannis Seimenis; Antonis Tzedakis; Apostolos Karantanas; John Damilakis
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

2.  Sparse sampling computed tomography (SpSCT) for detection of pulmonary embolism: a feasibility study.

Authors:  Andreas P Sauter; Felix K Kopp; Rolf Bippus; Julia Dangelmaier; Dominik Deniffel; Alexander A Fingerle; Felix Meurer; Daniela Pfeiffer; Roland Proksa; Ernst J Rummeny; Peter B Noël
Journal:  Eur Radiol       Date:  2019-05-09       Impact factor: 5.315

3.  Application value of iterative reconstruction with CTA to intractable headache patients.

Authors:  Yanfeng Xu; Shujing Yu; Li Zhang; Jing Zheng; Yuefeng Chen; Yanxu Che
Journal:  Exp Ther Med       Date:  2018-05-29       Impact factor: 2.447

4.  High-pitch, 120 kVp/30 mAs, low-dose dual-source chest CT with iterative reconstruction: Prospective evaluation of radiation dose reduction and image quality compared with those of standard-pitch low-dose chest CT in healthy adult volunteers.

Authors:  Hyun Kyung Lim; Hong Il Ha; Hye Jeon Hwang; Kwanseop Lee
Journal:  PLoS One       Date:  2019-01-24       Impact factor: 3.240

5.  Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage.

Authors:  Mercy H Mazurek; Bradley A Cahn; Matthew M Yuen; Anjali M Prabhat; Isha R Chavva; Jill T Shah; Anna L Crawford; E Brian Welch; Jonathan Rothberg; Laura Sacolick; Michael Poole; Charles Wira; Charles C Matouk; Adrienne Ward; Nona Timario; Audrey Leasure; Rachel Beekman; Teng J Peng; Jens Witsch; Joseph P Antonios; Guido J Falcone; Kevin T Gobeske; Nils Petersen; Joseph Schindler; Lauren Sansing; Emily J Gilmore; David Y Hwang; Jennifer A Kim; Ajay Malhotra; Gordon Sze; Matthew S Rosen; W Taylor Kimberly; Kevin N Sheth
Journal:  Nat Commun       Date:  2021-08-25       Impact factor: 14.919

6.  Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study.

Authors:  Sepideh Iranmakani; Amir Reza Jahanshahi; Parinaz Mehnati; Tohid Mortezazadeh; Davood Khezerloo
Journal:  J Med Signals Sens       Date:  2021-12-28

7.  Gamma Radiation Image Noise Prediction Method Based on Statistical Analysis and Random Walk.

Authors:  Dongjie Li; Haipeng Deng; Gang Yao; Jicheng Jiang; Yubao Zhang
Journal:  Sensors (Basel)       Date:  2022-09-27       Impact factor: 3.847

8.  Individualization of computed tomography protocols for suspected pulmonary embolism: a national investigation of routines.

Authors:  Berit Dymbe; Elisabeth Vespestad Mæland; Jorunn Rønhovde Styve; Albertina Rusandu
Journal:  J Int Med Res       Date:  2020-04       Impact factor: 1.671

9.  Diagnostic accuracy of X-ray versus CT in COVID-19: a propensity-matched database study.

Authors:  Aditya Borakati; Adrian Perera; James Johnson; Tara Sood
Journal:  BMJ Open       Date:  2020-11-06       Impact factor: 2.692

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.