Literature DB >> 2813771

Craniosynostosis: image quality, confidence, and correctness in diagnosis.

T K Pilgram1, M W Vannier, C F Hildebolt, J L Marsh, W H McAlister, G D Shackelford, C J Offutt, R H Knapp.   

Abstract

The authors used the diagnosis of craniosynostosis to compare subjective evaluation of image quality with objective diagnostic utility. They studied in detail the responses of one observer, who read plain radiographs, computed tomographic (CT) scans, and three-dimensional reconstructions of CT scans (obtained with three different methods) for 82 patients with this diagnosis. The observer rated image quality and certainty in diagnosis made from each image. Subjective and objective performances were found to be strongly linked. High-quality images served as the basis for more accurate diagnoses than low-quality images. The increase in diagnostic performance results primarily from increased specificity, a fact that suggests that specificity and the concomitant diagnosis of normalcy are the focus of attention when image quality is evaluated.

Entities:  

Mesh:

Year:  1989        PMID: 2813771     DOI: 10.1148/radiology.173.3.2813771

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction.

Authors:  Touko Kaasalainen; Kirsi Palmu; Anniina Lampinen; Vappu Reijonen; Junnu Leikola; Riku Kivisaari; Mika Kortesniemi
Journal:  Pediatr Radiol       Date:  2015-05-05

2.  Comparison of visual grading and free-response ROC analyses for assessment of image-processing algorithms in digital mammography.

Authors:  F Zanca; C Van Ongeval; F Claus; J Jacobs; R Oyen; H Bosmans
Journal:  Br J Radiol       Date:  2012-07-27       Impact factor: 3.039

3.  Calcaneal and pelvic fractures: diagnostic evaluation by three-dimensional computed tomography scans.

Authors:  M W Vannier; C F Hildebolt; L A Gilula; T K Pilgram; F Mann; B S Monsees; W A Murphy; W G Totty; C J Offutt
Journal:  J Digit Imaging       Date:  1991-08       Impact factor: 4.056

4.  Optimised low-dose multidetector CT protocol for children with cranial deformity.

Authors:  Jose Luis Vazquez; Miguel Angel Pombar; Jose Manuel Pumar; Victor Miguel del Campo
Journal:  Eur Radiol       Date:  2013-03-16       Impact factor: 5.315

5.  Patterns of skull base fracture: a three-dimensional computed tomographic study.

Authors:  Q M Ali; B Dietrich; H Becker
Journal:  Neuroradiology       Date:  1994-11       Impact factor: 2.804

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.