Literature DB >> 28135014

Biocompatibility, bone healing, and safety evaluation in rabbits with an IlluminOss bone stabilization system.

Amanda L McSweeney1, Brett G Zani1, Rose Baird1, James R L Stanley1, Alison Hayward1, Peter M Markham1, Gregory A Kopia2, Elazer R Edelman3, Robert Rabiner4.   

Abstract

Bone healing, biocompatibility, and safety employing the IlluminOss System (IS), comprised of an inflatable balloon filled with photopolymerizable liquid monomer, was evaluated in New Zealand white rabbits. Successful bone healing and callus remodeling over 6 months was demonstrated radiologically and histologically with IS implants in fenestrated femoral cortices. Biocompatibility was demonstrated with IS implants in brushed, flushed femoral intramedullary spaces, eliciting no adverse, local, or systemic responses and with similar biocompatibility to K-wires in contralateral femurs up to 1 year post-implant. Lastly simulated clinical failures demonstrated the safety of IS implants up to 1 year in the presence of liquid or polymerized polymer within the intramedullary space. Polymerized material displayed cortical bone and vasculature effects comparable to mechanical disruption of the endosteum. In the clinically unlikely scenario with no remediation or polymerization, a high dose monomer injection resulted in marked necrosis of cortical bone, as well as associated vasculature, endosteum, and bone marrow. Overall, when polymerized and hardened within bone intramedullary spaces, this light curable monomer system may provide a safe and effective method for fracture stabilization.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2181-2190, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  biocompatibility; fracture stabilization; intramedullary; light-curable; polymer

Mesh:

Year:  2017        PMID: 28135014      PMCID: PMC5534392          DOI: 10.1002/jor.23532

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  30 in total

Review 1.  The biological and physiological effects of intramedullary reaming.

Authors:  H-C Pape; P Giannoudis
Journal:  J Bone Joint Surg Br       Date:  2007-11

2.  Reaction of bone to methacrylate after hip arthroplasty: a long-term gross, light microscopic, and scanning electron microscopic study.

Authors:  H G Willert; J Ludwig; M Semlitsch
Journal:  J Bone Joint Surg Am       Date:  1974-10       Impact factor: 5.284

3.  Stimulation of the inflammatory system by reamed and unreamed nailing of femoral fractures. An analysis of the second hit.

Authors:  P V Giannoudis; R M Smith; M C Bellamy; J F Morrison; R A Dickson; P J Guillou
Journal:  J Bone Joint Surg Br       Date:  1999-03

Review 4.  Physical and biological aspects of fracture healing with special reference to internal fixation.

Authors:  S M Perren
Journal:  Clin Orthop Relat Res       Date:  1979 Jan-Feb       Impact factor: 4.176

5.  Management of pulmonary embolism during acrylic vertebroplasty.

Authors:  Piergiorgio Tozzi; Yasmine Abdelmoumene; Antonio F Corno; Philip A Gersbach; Henri-Marcel Hoogewoud; Ludwig K von Segesser
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

6.  The treatment of dislocated humeral head fractures with a new proximal intramedullary nail system.

Authors:  Bernd Füchtmeier; Stefan Bröckner; Reiner Hente; Mohamad Maghsudi; Michael Nerlich; Lukas Prantl
Journal:  Int Orthop       Date:  2007-06-28       Impact factor: 3.075

Review 7.  Tibia fractures. An overview of evaluation and treatment.

Authors:  Noreen C Miller; Aaron E Askew
Journal:  Orthop Nurs       Date:  2007 Jul-Aug       Impact factor: 0.913

Review 8.  Chemical and physical properties of bone cement for vertebroplasty.

Authors:  Po-Liang Lai; Lih-Hui Chen; Wen-Jer Chen; I-Ming Chu
Journal:  Biomed J       Date:  2013 Jul-Aug       Impact factor: 4.910

Review 9.  Thermal necrosis after tibial reaming for intramedullary nail fixation. A report of three cases.

Authors:  M Leunig; R Hertel
Journal:  J Bone Joint Surg Br       Date:  1996-07

10.  Internal fixation of proximal humeral fractures with a Polarus humeral nail.

Authors:  Yoichi Koike; Tatsuro Komatsuda; Katsumi Sato
Journal:  J Orthop Traumatol       Date:  2008-07-16
View more
  2 in total

1.  Intramedullary Stabilization of Pubic Ramus Fractures in Elderly Patients With a Photodynamic Bone Stabilization System (IlluminOss).

Authors:  Stavros Oikonomidis; Ahmad Alabsi; Ghazi Ashqar; Markus Graf; Rolf Sobottke
Journal:  Geriatr Orthop Surg Rehabil       Date:  2019-04-25

2.  The IlluminOss® photodynamic bone stabilization system for pathological osteolyses and fractures of the humerus: indications, advantages and limits in a series of 12 patients at 24 months of minimum follow-up.

Authors:  Carmine Zoccali; Dario Attala; Mattia Pugliese; Alessandra Scotto di Uccio; Jacopo Baldi
Journal:  BMC Musculoskelet Disord       Date:  2021-01-11       Impact factor: 2.362

  2 in total