Effects of 6 Single-File Systems on Dentinal Crack Formation.

Eugenio Pedullà1, Francesco Genovesi2, Silvia Rapisarda2, Giusy R M La Rosa2, Nicola M Grande3, Gianluca Plotino4, Carlos G Adorno5.   

Abstract

INTRODUCTION: The purpose of this study was to compare the formation of microcracks after canal preparation performed with different single-file systems as One Shape (Micro-Mega, Besancon, Cedex, France), F6 SkyTaper (Komet Italia Srl, Milan, Italy), HyFlex EDM (Coltene/Whaledent AG, Altstatten, Switzerland), WaveOne (Dentsply Maillefer, Ballaigues, Switzerland), Reciproc (VDW, Munich, Germany), and WaveOne Gold (Dentsply Maillefer).
METHODS: Eighty-four human extracted mandibular central incisors (40-60 y) were selected and divided into 6 experimental groups (n = 12 teeth) and a control group (unprepared teeth): One Shape (group 1), F6 SkyTaper (group 2), HyFlex EDM (group 3), WaveOne (group 4), Reciproc (group 5), and WaveOne Gold (group 6). Roots were then sectioned at 3, 6, and 9 mm from the apex, and the surface was observed under a stereomicroscope. Data were analyzed using logistic regression (P < .05).
RESULTS: No cracks were observed in the control group. All the systems tested caused cracks, mainly in the apical section (3 mm). HyFlex EDM (33.3%) and WaveOne Gold (58.3%) showed fewer microcracks than other experimental groups (P < .01); however, no significant difference was found between them in crack formation (P > .05). There was no difference among the other experimental groups (P > .05).
CONCLUSIONS: All the instruments tested created dentinal cracks. Within the limitations of this study, the flexibility of nickel-titanium instruments because of heat treatment seems to have a significant influence on dentinal crack formation. HyFlex EDM and WaveOne Gold caused less microcracks than the other instruments tested.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  F6 SkyTaper; HyFlex EDM; Wave One Gold; microcracks; single-file system

Mesh:

Year:  2017        PMID: 28131416     DOI: 10.1016/j.joen.2016.10.038

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  The existence of butterfly effect and its impact on the dentinal microhardness and crack formation after root canal instrumentation.

Authors:  Galvin Sim Siang Lin; Nik Rozainah Nik Abdul Ghani; Tahir Yusuf Noorani
Journal:  Odontology       Date:  2021-01-17       Impact factor: 2.634

2.  Dentinal microcracks induced by endodontic procedures: A scientometric and bibliometric analysis.

Authors:  Stéphanie Quadros Tonelli; Kênia Soares de Toubes; André Maués Brabo Pereira; Antônio Carlos de Oliveira Miranda; Letícia Ladeia Fernandes; Eduardo Nunes; Frank Ferreira Silveira
Journal:  J Conserv Dent       Date:  2022-05-02

3.  Effect of post space preparation drills on the incidence of root dentin defects.

Authors:  Thaíse Ayres Bezerra Zuli; Orlando Aguirre Guedes; Gislaine Figueiredo Zarza Arguello Gonçalves; Aurélio Rosa da Silva Júnior; Álvaro Henrique Borges; Andreza Maria Fábio Aranha
Journal:  Restor Dent Endod       Date:  2020-10-16

4.  Effects of ultrasonic refinement on endodontic access cavity walls: A microcomputed tomography analysis.

Authors:  Carla Zogheib; Reina Roumi; Gaël Bourbouze; Alfred Naaman; Issam Khalil; Gianluca Plotino
Journal:  J Conserv Dent       Date:  2021-07-05

5.  Light-emitting diode assessment of dentinal defects: the role of presumed extraction forces.

Authors:  Marcelo Santos Coelho; Steven J Card; Peter Z Tawil
Journal:  Restor Dent Endod       Date:  2017-07-24

6.  Synchrotron radiation-based micro-computed tomographic analysis of dentinal microcracks using rotary and reciprocating file systems: An in vitro study.

Authors:  Harikumar Vemisetty; N Tulasi Priya; Balwant Singh; Pooja Yenubary; Ashish Kumar Agarwal; Jayaprada Reddy Surakanti
Journal:  J Conserv Dent       Date:  2020-12-04

7.  Cyclic fatigue resistance, torsional resistance, and metallurgical characteristics of M3 Rotary and M3 Pro Gold NiTi files.

Authors:  Eugenio Pedullà; Fabio Lo Savio; Giusy Rita Maria La Rosa; Gabriele Miccoli; Elena Bruno; Silvia Rapisarda; Seok Woo Chang; Ernesto Rapisarda; Guido La Rosa; Gianluca Gambarini; Luca Testarelli
Journal:  Restor Dent Endod       Date:  2018-04-23

8.  Micro-computed tomographic evaluation of dentinal defects after root canal preparation with hyflex edm and vortex blue rotary systems.

Authors:  Jyothi Mandava; Rajiv-Kumar Yelisela; Sampath-Kumar Arikatla; Ravi-Chandra Ravi
Journal:  J Clin Exp Dent       Date:  2018-09-01

9.  The Influence of Dentin Age and the Presence of Cracks in Removal of the Root Filling Material.

Authors:  Lilian Rachel de Lima Aboud; Ricardo Tadeu Lopes; Bernardo Camargo Dos Santos; Thaís Maria Pires Dos Santos; Leonardo Aboud Costa Viana; Miriam F Zaccaro Scelza
Journal:  Iran Endod J       Date:  2018

10.  Cyclic fatigue, torsional failure, and flexural resistance of rotary and reciprocating instruments.

Authors:  Carlos Henrique Ribeiro Camargo; Tatiane Sampaio Bittencourt; Amjad Abu Hasna; Renato Miotto Palo; Cláudio Antonio Talge Carvalho; Marcia Carneiro Valera
Journal:  J Conserv Dent       Date:  2021-01-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.