Literature DB >> 28120143

Online Studies on Variation in Orthopedic Surgery: Computed Tomography in MPEG4 Versus DICOM Format.

Jos J Mellema1, Wouter H Mallee2, Thierry G Guitton2, C Niek van Dijk2, David Ring3, Job N Doornberg2.   

Abstract

The purpose of this study was to compare the observer participation and satisfaction as well as interobserver reliability between two online platforms, Science of Variation Group (SOVG) and Traumaplatform Study Collaborative, for the evaluation of complex tibial plateau fractures using computed tomography in MPEG4 and DICOM format. A total of 143 observers started with the online evaluation of 15 complex tibial plateau fractures via either the SOVG or Traumaplatform Study Collaborative websites using MPEG4 videos or a DICOM viewer, respectively. Observers were asked to indicate the absence or presence of four tibial plateau fracture characteristics and to rate their satisfaction with the evaluation as provided by the respective online platforms. The observer participation rate was significantly higher in the SOVG (MPEG4 video) group compared to that in the Traumaplatform Study Collaborative (DICOM viewer) group (75 and 43%, respectively; P < 0.001). The median observer satisfaction with the online evaluation was seven (range, 0-10) using MPEG4 video compared to six (range, 1-9) using DICOM viewer (P = 0.11). The interobserver reliability for recognition of fracture characteristics in complex tibial plateau fractures was higher for the evaluation using MPEG4 video. In conclusion, observer participation and interobserver reliability for the characterization of tibial plateau fractures was greater with MPEG4 videos than with a standard DICOM viewer, while there was no difference in observer satisfaction. Future reliability studies should account for the method of delivering images.

Entities:  

Keywords:  Computed tomography; DICOM; MPEG; Orthopedic surgery; Tibial plateau fractures; Variation

Mesh:

Year:  2017        PMID: 28120143      PMCID: PMC5603427          DOI: 10.1007/s10278-016-9939-0

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  23 in total

1.  Improved interobserver variation after training of doctors in the Neer system. A randomised trial.

Authors:  S Brorson; J Bagger; A Sylvest; A Hrøbjartsson; A Høbjartsson
Journal:  J Bone Joint Surg Br       Date:  2002-09

2.  Inter-observer variation in the diagnosis of coronal articular fracture lines in the lunate facet of the distal radius.

Authors:  Mathieu M E Wijffels; Thierry G Guitton; David Ring
Journal:  Hand (N Y)       Date:  2012-09

3.  Interobserver reliability of computed tomography to diagnose scaphoid waist fracture union.

Authors:  Geert A Buijze; Mathieu M E Wijffels; Thierry G Guitton; Ruby Grewal; C Niek van Dijk; David Ring
Journal:  J Hand Surg Am       Date:  2012-02       Impact factor: 2.230

4.  Radiographic diagnosis of scapholunate dissociation among intra-articular fractures of the distal radius: interobserver reliability.

Authors:  Gertraud Gradl; Valentin Neuhaus; Thomas Fuchsberger; Thierry G Guitton; Karl-Josef Prommersberger; David Ring
Journal:  J Hand Surg Am       Date:  2013-07-30       Impact factor: 2.230

5.  Sample size and optimal designs for reliability studies.

Authors:  S D Walter; M Eliasziw; A Donner
Journal:  Stat Med       Date:  1998-01-15       Impact factor: 2.373

6.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

7.  Interobserver reliability of radial head fracture classification: two-dimensional compared with three-dimensional CT.

Authors:  Thierry G Guitton; David Ring
Journal:  J Bone Joint Surg Am       Date:  2011-11-02       Impact factor: 5.284

8.  Diagnosis of elbow fracture patterns on radiographs: interobserver reliability and diagnostic accuracy.

Authors:  Job N Doornberg; Thierry G Guitton; David Ring
Journal:  Clin Orthop Relat Res       Date:  2012-12-18       Impact factor: 4.176

9.  Interobserver reliability of coronoid fracture classification: two-dimensional versus three-dimensional computed tomography.

Authors:  Anneluuk Lindenhovius; Paul Jack Karanicolas; Mohit Bhandari; Niek van Dijk; David Ring
Journal:  J Hand Surg Am       Date:  2009-10-14       Impact factor: 2.230

10.  Interobserver variability in the treatment of little finger metacarpal neck fractures.

Authors:  Rick Tosti; Asif M Ilyas; Jos J Mellema; Thierry G Guitton; David Ring
Journal:  J Hand Surg Am       Date:  2014-07-14       Impact factor: 2.230

View more
  2 in total

1.  Agreement on fixation of pediatric supracondylar humerus fractures.

Authors:  Willemijn Spierenburg; Anne Britt E Dekker; Job N Doornberg; Pieta Krijnen; Michel P J van den Bekerom; Inger B Schipper
Journal:  Eur J Trauma Emerg Surg       Date:  2022-04-16       Impact factor: 2.374

2.  Reliability of Diagnosis of Partial Union of Scaphoid Waist Fractures on Computed Tomography.

Authors:  Tessa Drijkoningen; Paul Willem Louis Ten Berg; Thierry G Guitton; David Ring; Chaitanya S Mudgal
Journal:  J Hand Microsurg       Date:  2018-03-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.