Literature DB >> 28117620

Association between patient activity and long-term cardiac death in patients with implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators.

Shuang Zhao1, Keping Chen1, Yangang Su2, Wei Hua1, Silin Chen3, Zhaoguang Liang4, Wei Xu5, Yan Dai1, Zhimin Liu1, Xiaohan Fan1, Cuihong Hou1, Shu Zhang1.   

Abstract

Background Patient activity (PA) has been demonstrated to predict all-cause mortality. However, the association between PA and cardiac death is unclear. Aims The aims of this study were to determine whether PA can predict cardiac death and what is the cut-off of PA to discriminate cardiac death, as well as the mechanism underlying the relationship between PA and survival in patients with home monitoring. Methods This study retrospectively analysed clinical and implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator device data in 845 patients. Data regarding PA and PP variability during the first 30-60 days of home monitoring were collected, and mean values were calculated. The primary endpoint was cardiac death, and the secondary endpoint was all-cause mortality. Results The mean PA percentage was 11 ± 5.8%. Based on receiver operating characteristic curve analysis, we determined that a PA cut-off value of 7.84% (113 min) can predict cardiac death. During a mean follow-up period of 31.1 ± 12.9 months (ranging from three to 60 months), PA ≤ 7.84% was associated with increased risks of cardiac death in an unadjusted analysis; after adjusting in a multivariate Cox model, the relationship remained significant between PA≤7.84% and cardiac death (hazard ratio = 3.644, 95% confidence interval = 2.424-5.477, p < 0.001). Moreover, a significant correlation was observed between PA and PP variability ( r = 0.601, p < 0.001). Conclusions A baseline PA ≤ 7.84% was associated with a higher risk of cardiac death in patients who have survived more than three months after implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator implantation. PA had a sizable effect on heart rate variability, reflecting autonomic function.

Entities:  

Keywords:  Patient activity; cardiac death; cardiac resynchronization therapy defibrillator; heart rate variability; implantable cardioverter-defibrillator

Mesh:

Year:  2017        PMID: 28117620     DOI: 10.1177/2047487316688982

Source DB:  PubMed          Journal:  Eur J Prev Cardiol        ISSN: 2047-4873            Impact factor:   7.804


  7 in total

1.  Comparative Analysis of Physical Activity Detected via an External Accelerometer and Cardiac Implantable Electronic Devices.

Authors:  Chun-Kai Chen; Li-Ying Cheng; Shan-Wei Hsu; Min-Tsun Liao; Po-Wen Ku; Yen-Bin Liu
Journal:  Front Cardiovasc Med       Date:  2022-05-27

2.  Implantable device measured objective daily physical activity as a predictor of long-term all-cause mortality and cardiac death in patients with age > 75 years and high risk of sudden cardiac death: a cohort study : Physical activity and patients over 75 years old.

Authors:  Xiaoyao Li; Keping Chen; Wei Hua; Yangang Su; Jiefu Yang; Zhaoguang Liang; Wei Xu; Shuang Zhao; Zeyi Li; Shu Zhang
Journal:  BMC Geriatr       Date:  2022-02-16       Impact factor: 3.921

Review 3.  Accelerometer-assessed physical behavior and the association with clinical outcomes in implantable cardioverter-defibrillator recipients: A systematic review.

Authors:  Maarten Z H Kolk; Diana M Frodi; Tariq O Andersen; Joss Langford; Soeren Z Diederichsen; Jesper H Svendsen; Hanno L Tan; Reinoud E Knops; Fleur V Y Tjong
Journal:  Cardiovasc Digit Health J       Date:  2021-11-24

4.  Measuring Physical Activity With Implanted Cardiac Devices: A Systematic Review.

Authors:  Lindsey Rosman; Rachel Lampert; Samuel F Sears; Matthew M Burg
Journal:  J Am Heart Assoc       Date:  2018-05-17       Impact factor: 5.501

5.  Physical activity is reduced prior to ventricular arrhythmias in patients with a wearable cardioverter defibrillator.

Authors:  Ashley E Burch; Benjamin D'Souza; J Rod Gimbel; Ursula Rohrer; Tsuyoshi Masuda; Samuel Sears; Daniel Scherr
Journal:  Clin Cardiol       Date:  2019-11-11       Impact factor: 2.882

6.  Monitoring functional capacity in heart failure.

Authors:  Massimo F Piepoli; Ilaria Spoletini; Giuseppe Rosano
Journal:  Eur Heart J Suppl       Date:  2019-12-31       Impact factor: 1.803

7.  Dose-response association of implantable device-measured physical activity with long-term cardiac death and all-cause mortality in patients at high risk of sudden cardiac death: a cohort study.

Authors:  Xiaoyao Li; Shuang Zhao; Keping Chen; Wei Hua; Yangang Su; Jiefu Yang; Zhaoguang Liang; Wei Xu; Shu Zhang
Journal:  Int J Behav Nutr Phys Act       Date:  2020-09-21       Impact factor: 6.457

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.