The Homburg Lung: Efficacy and Safety of a Minimal-Invasive Pump-Driven Device for Veno-Venous Extracorporeal Carbon Dioxide Removal.

Frederik Seiler1, Franziska C Trudzinski, Kai Hennemann, Tom Niermeyer, Christian Schmoll, Annegret Kamp, Robert Bals, Ralf M Muellenbach, Hendrik Haake, Philipp M Lepper.   

Abstract

Extracorporeal carbon dioxide removal (ECCO2R) is increasingly considered a viable therapeutic approach in the management of hypercapnic lung failure to avoid intubation or to allow lung-protective ventilator settings. This study aimed to analyze efficacy and safety of a minimal-invasive ECCO2R device, the Homburg lung. The Homburg lung is a pump-driven system for veno-venous ECCO2R with ¼″ tubing and a 0.8 m surface oxygenator. Vascular access is usually established via a 19F/21 cm bilumen cannula in the right internal jugular vein. For this work, we screened patient registries from two German centers for patients who underwent ECCO2R with the Homburg lung because of hypercapnic lung failure since 2013. Patients who underwent extracorporeal membrane oxygenation before ECCO2R were excluded. Patients who underwent ECCO2R more than one time were only included once. In total, 24 patients (aged 53.86 ± 12.49 years; 62.5% male) were included in the retrospective data analysis. Ventilatory failure occurred because of chronic obstructive pulmonary disease (50%), cystic fibrosis (16.7%), acute respiratory distress syndrome (12.5%), and other origins (20.8%). The system generated a blood flow of 1.18 ± 0.23 liters per minute (lpm). Sweep gas flow was 3.87 ± 2.97 lpm. Within 4 hours, paCO2 could be reduced significantly from 82.05 ± 15.57 mm Hg to 59.68 ± 12.27 mm Hg, thereby, increasing pH from 7.23 ± 0.10 to 7.36 ± 0.09. Cannulation-associated complications were transient arrhythmia (1/24 patients) and air embolism (1/24). Fatal complications did not occur. In conclusion, the Homburg lung provides effective carbon dioxide removal in hypercapnic lung failure. The cannulation is a safe procedure, with complication rates comparable to those in central venous catheter implantation.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28114193     DOI: 10.1097/MAT.0000000000000522

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

Review 1.  [Update: acute hypercapnic respiratory failure].

Authors:  F Seiler; F C Trudzinski; M Kredel; C Lotz; P M Lepper; R M Muellenbach
Journal:  Med Klin Intensivmed Notfmed       Date:  2017-07-13       Impact factor: 0.840

2.  A mock circulation loop to test extracorporeal CO2 elimination setups.

Authors:  Leonie S Schwärzel; Anna M Jungmann; Nicole Schmoll; Frederik Seiler; Ralf M Muellenbach; Joachim Schenk; Quoc Thai Dinh; Robert Bals; Philipp M Lepper; Albert J Omlor
Journal:  Intensive Care Med Exp       Date:  2020-09-11

3.  Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination.

Authors:  Leonie S Schwärzel; Anna M Jungmann; Nicole Schmoll; Stefan Caspari; Frederik Seiler; Ralf M Muellenbach; Moritz Bewarder; Quoc Thai Dinh; Robert Bals; Philipp M Lepper; Albert J Omlor
Journal:  Membranes (Basel)       Date:  2021-05-27

4.  Bench Validation of a Compact Low-Flow CO2 Removal Device.

Authors:  Alexandra G May; R Garrett Jeffries; Brian J Frankowski; Greg W Burgreen; William J Federspiel
Journal:  Intensive Care Med Exp       Date:  2018-09-24

5.  A mock circulation loop to test extracorporeal CO2 elimination setups.

Authors:  Leonie S Schwärzel; Anna M Jungmann; Nicole Schmoll; Frederik Seiler; Ralf M Muellenbach; Joachim Schenk; Quoc Thai Dinh; Robert Bals; Philipp M Lepper; Albert J Omlor
Journal:  Intensive Care Med Exp       Date:  2020-09-11