Local Transverse-Slice-Based Level-Set Method for Segmentation of 3-D High-Frequency Ultrasonic Backscatter From Dissected Human Lymph Nodes.

Alain Coron, Jonathan Mamou, Emi Saegusa-Beecroft, Tadashi Yamaguchi, Eugene Yanagihara, Junji Machi, S Lori Bridal, Ernest Joseph Feleppa.   

Abstract

OBJECTIVE: To detect metastases in freshly excised human lymph nodes (LNs) using three-dimensional (3-D), high-frequency, quantitative ultrasound (QUS) methods, the LN parenchyma (LNP) must be segmented to preclude QUS analysis of data in regions outside the LNP and to compensate ultrasound attenuation effects due to overlying layers of LNP and residual perinodal fat (PNF).
METHODS: After restoring the saturated radio-frequency signals from PNF using an approach based on smoothing cubic splines, the three regions, i.e., LNP, PNF, and normal saline (NS), in the LN envelope data are segmented using a new, automatic, 3-D, three-phase, statistical transverseslice-based level-set (STS-LS) method that amends Lankton's method. Due to ultrasound attenuation and focusing effects, the speckle statistics of the envelope data vary with imaged depth. Thus, to mitigate depth-related inhomogeneity effects, the STS-LS method employs gamma probabilitydensity functions to locally model the speckle statistics within consecutive transverse slices.
RESULTS: Accurate results were obtained on simulated data. On a representative dataset of 54 LNs acquired from colorectal-cancer patients, the Dice similarity coefficient for LNP, PNF, and NS were 0.938 ± 0.025, 0.832 ± 0.086, and 0.968 ± 0.008, respectively, when compared to expert manual segmentation.
CONCLUSION: The STS-LS outperforms the established methods based on global and local statistics in our datasets and is capable of accurately handling the depth-dependent effects due to attenuation and focusing. SIGNIFICANCE: This advance permits the automatic QUS-based cancer detection in the LNs. Furthermore, the STS-LS method could potentially be used in a wide range of ultrasound-imaging applications suffering from depth-dependent effects.

Entities:  

Mesh:

Year:  2016        PMID: 28113305     DOI: 10.1109/TBME.2016.2614137

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  3 in total

1.  Quantification of Thoracic Lymphatic Flow Patterns Using Dynamic Contrast-enhanced MR Lymphangiography.

Authors:  Qiang Zheng; Maxim Itkin; Yong Fan
Journal:  Radiology       Date:  2020-05-05       Impact factor: 11.105

2.  Segmentation of 3-D High-Frequency Ultrasound Images of Human Lymph Nodes Using Graph Cut With Energy Functional Adapted to Local Intensity Distribution.

Authors:  Jen-Wei Kuo; Jonathan Mamou; Yao Wang; Emi Saegusa-Beecroft; Junji Machi; Ernest J Feleppa
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-09       Impact factor: 2.725

Review 3.  Basic concept and clinical applications of quantitative ultrasound (QUS) technologies.

Authors:  Tadashi Yamaguchi
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.