Literature DB >> 28108082

Analysis of drugs of abuse in human plasma using microextraction by packed sorbents and ultra-high-performance liquid chromatography.

P Fernández1, M González2, M Regenjo1, A M Ares2, A M Fernández3, R A Lorenzo2, A M Carro4.   

Abstract

A miniaturized and simple method based on digitally programmed microextraction by packed sorbent (eVol®-MEPS) coupled to ultra-performance liquid chromatography (UPLC) has been developed for quantitative determination of three synthetic cathinones and seven conventional drugs of abuse and metabolites. The influence of several extraction parameters, such as washing and elution solvents were tested. In addition important variables affecting MEPS performance, namely sample volume, sorbent drying time, washing solvent volume, elution volume, number of extraction cycles, sorbent phase and pH, were evaluated using an asymmetrical screening design. The optimal experimental conditions involved 300μL of plasma, loading 10×100μL of sample through a C8/SCX sorbent in a MEPS syringe placed in the semi-automatic eVol® system, washing using 150μL H2O:MeOH (90:10, v/v), drying for 0.5min and elution using 200μL dichloromethane:2-propanol:ammonium hydroxide (78:20:2, v/v/v). The drugs separation was achieved using an ACQUITY BEH Shield RP18 column (2.1mm×100mm×1.7μm) in 3min. Under optimized conditions the proposed method was validated in terms of selectivity, linearity, limits of detection (LOD) and quantitation (LOQ), precision and matrix effect, using standard addition calibration. The combination of MEPS and UPLC provides a method for the primary screening of the analytes in 18min with excellent recoveries at three concentration levels, ranging between 80 and 104% (relative standard deviation <11%). The developed methodology has been successfully applied to plasma samples from polydrug abusers.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cathinones; Drugs of abuse; Microextraction by packed sorbent; Plasma; Ultra-performance-liquid chromatography

Mesh:

Substances:

Year:  2017        PMID: 28108082     DOI: 10.1016/j.chroma.2017.01.021

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

Review 1.  Interpol review of toxicology 2016-2019.

Authors:  Wing-Sum Chan; George Fai Wong; Chi-Wai Hung; Yau-Nga Wong; Kit-Mai Fung; Wai-Kit Lee; Kwok-Leung Dao; Chung-Wing Leung; Kam-Moon Lo; Wing-Man Lee; Bobbie Kwok-Keung Cheung
Journal:  Forensic Sci Int       Date:  2020-05-23       Impact factor: 2.395

Review 2.  Solventless Microextration Techniques for Pharmaceutical Analysis: The Greener Solution.

Authors:  Heba M Mohamed
Journal:  Front Chem       Date:  2022-01-13       Impact factor: 5.221

3.  Capacitively Coupled Plasma Discharge of Ionic Liquid Solutions to Synthesize Carbon Dots as Fluorescent Sensors.

Authors:  Ching-Bin Ke; Te-Ling Lu; Jian-Lian Chen
Journal:  Nanomaterials (Basel)       Date:  2018-05-26       Impact factor: 5.076

Review 4.  Green Approaches to Sample Preparation Based on Extraction Techniques.

Authors:  Alshymaa A Aly; Tadeusz Górecki
Journal:  Molecules       Date:  2020-04-09       Impact factor: 4.411

5.  [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction].

Authors:  Jianan Wei; Molin Qin; Junchao Yang; Liu Yang
Journal:  Se Pu       Date:  2021-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.