Literature DB >> 28105830

Improving Performance Metrics of Ultraviolet Photodissociation Mass Spectrometry by Selective Precursor Ejection.

Dustin D Holden1, Jennifer S Brodbelt1.   

Abstract

Confident protein identifications derived from high-throughput bottom-up and top-down proteomics workflows depend on acquisition of thousands of tandem mass spectrometry (MS/MS) spectra with adequate signal-to-noise and accurate mass assignments of the fragment ions. Ultraviolet photodissociation (UVPD) using 193 nm photons has proven to be well-suited for activation and fragmentation of peptides and proteins in ion trap mass spectrometers, but the spectral signal-to-noise ratio (S/N) is typically lower than that obtained from collisional activation methods. The lower S/N is attributed to the dispersion of ion current among numerous fragment ion channels (a,b,c,x,y,z ions). In addition, frequently UVPD is performed such that a relatively large population of precursor ions remains undissociated after the UV photoactivation period in order to prevent overdissociation into small uninformative or internal fragment ions. Here we report a method to improve spectral S/N and increase the accuracy of mass assignments of UVPD mass spectra via resonance ejection of undissociated precursor ions after photoactivation. This strategy, termed precursor ejection UVPD or PE-UVPD, allows the ion trap to be filled with more ions prior to UVPD while at the same time alleviating the space charge problems that would otherwise contribute to the skewing of mass assignments and reduction of S/N. Here we report the performance gains by implementation of PE-UVPD for peptide analysis in an ion trap mass spectrometer.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 28105830     DOI: 10.1021/acs.analchem.6b03777

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Ultraviolet Photodissociation Mass Spectrometry for Analysis of Biological Molecules.

Authors:  Jennifer S Brodbelt; Lindsay J Morrison; Inês Santos
Journal:  Chem Rev       Date:  2019-12-18       Impact factor: 60.622

2.  Enhancing the Signal-to-Noise of Diagnostic Fragment Ions of Unsaturated Glycerophospholipids via Precursor Exclusion Ultraviolet Photodissociation Mass Spectrometry (PEx-UVPD-MS).

Authors:  Samuel W J Shields; James D Sanders; Jennifer S Brodbelt
Journal:  Anal Chem       Date:  2022-08-02       Impact factor: 8.008

Review 3.  Top-Down Proteomics: Ready for Prime Time?

Authors:  Bifan Chen; Kyle A Brown; Ziqing Lin; Ying Ge
Journal:  Anal Chem       Date:  2017-12-15       Impact factor: 6.986

4.  Internal Fragments Generated by Electron Ionization Dissociation Enhance Protein Top-Down Mass Spectrometry.

Authors:  Muhammad A Zenaidee; Carter Lantz; Taylor Perkins; Wonhyuek Jung; Rachel R Ogorzalek Loo; Joseph A Loo
Journal:  J Am Soc Mass Spectrom       Date:  2020-08-17       Impact factor: 3.109

5.  In-situ sampling of lipids in tissues using a porous membrane microprobe for direct mass spectrometry analysis.

Authors:  Bin Jiao; Wei Zhou; Yikun Liu; Wenpeng Zhang; Zheng Ouyang
Journal:  Mater Today Bio       Date:  2022-09-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.