Literature DB >> 28100943

Comparison of the Clinical Outcome and Complications in Laparoscopic Hernia Repair of Inguinal Hernia With Mesh Fixation Using Fibrin Glue vs Tacker.

Prasant Chandra1, Deepak Phalgune1, Shashank Shah1.   

Abstract

Although laparoscopic repair offers a quick and less morbid way of treating hernias, complications like hematoma, seroma, neuralgia, recurrence, mesh infection, hydrocele, etc. are known. The present study was undertaken to compare various clinical outcomes between mesh fixation using fibrin glue and mesh fixation with tacker in a 3-months follow-up. One hundred patients aged 18 to 60 years having inguinal hernia admitted in Poona Hospital and Research Centre, Pune, between October 2012 and November 2014 for laparoscopic hernia surgery and ready to participate in this study were included. All of them underwent laparoscopic repair of hernia by total extra peritoneal (TEP) method following sample surgical protocol in all of them except for method of mesh fixation. Mean time calculated from insertion of the first trocar to beginning of skin suturing was 54.9 min in tacker group and 50.3 min in fibrin glue group with no statistically significant difference between the two. The incidence of urinary retention was significantly higher in tacker (34 %) as compared to fibrin glue (12 %) group. Incidence of hematoma was significantly higher in tacker group in 15-day follow-up, but there was no significant difference in hematoma formation at hernial sites in both groups after 15 days of follow-up. The incidence of neuralgia was significantly higher in the tacker group (24 %) compared with the fibrin glue group (2 %). Significantly, more number of people in the fibrin glue group 68 and 90 %, respectively, returned to work during 15 and 30 days follow-up as compared to the tacker group 46 and 64 %. Fibrin glue can be considered as an alternative to tacker for mesh fixation.

Entities:  

Keywords:  Fibrin glue; Laparoscopic hernia repair; Tack for mesh repair; Visual cosmesis scale

Year:  2015        PMID: 28100943      PMCID: PMC5218932          DOI: 10.1007/s12262-015-1410-9

Source DB:  PubMed          Journal:  Indian J Surg        ISSN: 0973-9793            Impact factor:   0.656


  20 in total

Review 1.  Staple versus fibrin glue fixation in laparoscopic total extraperitoneal repair of inguinal hernia: a systematic review and meta-analysis.

Authors:  Amit Kaul; Susan Hutfless; Hamilton Le; Senan A Hamed; Kevin Tymitz; Hien Nguyen; Michael R Marohn
Journal:  Surg Endosc       Date:  2012-02-21       Impact factor: 4.584

2.  The use of fibrin sealant in the prevention of seromas.

Authors:  D A Kulber; N Bacilious; E D Peters; L B Gayle; L Hoffman
Journal:  Plast Reconstr Surg       Date:  1997-03       Impact factor: 4.730

3.  Risk of postoperative urinary retention after laparoscopic (TAPP) or endoscopic (TEP) inguinal hernia repair.

Authors:  F Köckerling; D A Jacob; R Bittner; P Chowbey; D Lomanto; J Kukleta
Journal:  Surg Endosc       Date:  2012-10-06       Impact factor: 4.584

Review 4.  Laparoscopic surgery for inguinal hernia repair: systematic review of effectiveness and economic evaluation.

Authors:  K McCormack; B Wake; J Perez; C Fraser; J Cook; E McIntosh; L Vale; A Grant
Journal:  Health Technol Assess       Date:  2005-04       Impact factor: 4.014

5.  The impact of atraumatic fibrin sealant vs. staple mesh fixation in TAPP hernia repair on chronic pain and quality of life: results of a randomized controlled study.

Authors:  R H Fortelny; A H Petter-Puchner; C May; W Jaksch; T Benesch; Z Khakpour; H Redl; K S Glaser
Journal:  Surg Endosc       Date:  2011-08-19       Impact factor: 4.584

6.  [The history of treatment of groin hernia].

Authors:  Janusz Legutko; Radosław Pach; Rafał Solecki; Andrzej Matyja; Jan Kulig
Journal:  Folia Med Cracov       Date:  2008

7.  Randomized clinical trial of fibrin glue versus tacked fixation in laparoscopic groin hernia repair.

Authors:  Mette A Tolver; Jacob Rosenberg; Poul Juul; Thue Bisgaard
Journal:  Surg Endosc       Date:  2013-01-26       Impact factor: 4.584

8.  Laparoscopic inguinal herniorrhaphy. Results of a multicenter trial.

Authors:  R J Fitzgibbons; J Camps; D A Cornet; N X Nguyen; B S Litke; R Annibali; G M Salerno
Journal:  Ann Surg       Date:  1995-01       Impact factor: 12.969

Review 9.  How to calculate sample size for different study designs in medical research?

Authors:  Jaykaran Charan; Tamoghna Biswas
Journal:  Indian J Psychol Med       Date:  2013-04

10.  Laparoscopic repair of inguinal hernia using Surgisis mesh and fibrin sealant.

Authors:  Arthur P Fine
Journal:  JSLS       Date:  2006 Oct-Dec       Impact factor: 2.172

View more
  2 in total

Review 1.  Medical Adhesives and Their Role in Laparoscopic Surgery-A Review of Literature.

Authors:  Maciej Mazur; Wojciech Zakrzewski; Maria Szymonowicz; Zbigniew Rybak
Journal:  Materials (Basel)       Date:  2022-07-28       Impact factor: 3.748

Review 2.  Safety considerations in laparoscopic surgery: A narrative review.

Authors:  Brij Madhok; Kushan Nanayakkara; Kamal Mahawar
Journal:  World J Gastrointest Endosc       Date:  2022-01-16
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.