Guilherme Brasil Grezzana1, David William Moraes2, Airton Tetelbon Stein2,3, Lucia Campos Pellanda1,2. 1. Instituto de Cardiologia - Fundação Universitária de Cardiologia; Porto Alegre, RS - Brazil. 2. Universidade Federal de Ciências da Saúde de Porto Alegre - UFCSPA; Porto Alegre, RS - Brazil. 3. Universidade Luterana do Brasil (ULBRA), Canoas, RS - Brazil.
Abstract
BACKGROUND: : Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. OBJECTIVE: : To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. METHODS: : A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. RESULTS: : There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. CONCLUSION: : The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. FUNDAMENTOS:: A hipertensão arterial sistêmica é um fator de risco importante para desfechos cardiovasculares. Médicos da atenção primária à saúde (APS) devem estar preparados para atuar adequadamente na prevenção de fatores de risco cardiovascular. No entanto, as taxas de pacientes com pressão arterial (PA) controlada continuam baixas. O impacto da reclassificação do diagnóstico de hipertensão pela utilização da monitorização ambulatorial da PA (MAPA) de 24 horas pode levar a diferentes decisões médicas na APS. OBJETIVO:: Avaliar a concordância entre as PAs medidas por método convencional por médicos da APS e por MAPA de 24 horas, considerando diferentes limiares de normalidade para a MAPA de 24 horas de acordo com as recomendações da V Diretriz Brasileira de MAPA e da Diretriz da Sociedade Europeia de Hipertensão. MÉTODOS:: Estudo transversal com 569 pacientes hipertensos. A PA foi medida inicialmente por médicos da APS e, posteriormente, pela MAPA de 24 horas. As medidas foram obtidas de forma independente entre os dois métodos. Os alvos terapêuticos para a PA convencional seguiram as orientações do Eighth Joint National Committee (JNC 8), das V Diretrizes Brasileiras de MAPA e das Diretrizes Europeias de Hipertensão de 2013. RESULTADOS:: Foi observada uma acurácia de 54,8% (intervalo de confiança de 95% [IC95%] 0,51 - 0,58%) para a PA aferida de forma convencional quando comparada à obtida com a MAPA de 24 horas, além de uma sensibilidade de 85% (IC95% 80,8 - 88,6%), especificidade de 31,9% (IC95% 28,7 - 34,7%) e kappa de 0,155, quando consideradas as Diretrizes Europeias de Hipertensão. Quando utilizados limiares mais rígidos para caracterizar a PA como "normal" pela MAPA, foi identificada uma acurácia de 45% (IC95% 0,41 - 0,47%) pela medida convencional quando comparada à obtida pela MAPA de 24 horas, além de uma sensibilidade de 86,7% (IC95% 0,81 - 0,91%), especificidade de 29% (IC95% 0,26 - 0,30%) e kappa de 0,103. CONCLUSÃO:: As medidas de PA avaliadas pelos médicos da APS apresentaram baixa acurácia quando comparadas às medidas pela MAPA de 24 horas, independente do limiar utilizado pelas diferentes diretrizes.
BACKGROUND: : Hypertension is an important risk factor for cardiovascular outcomes. Primary health care (PHC) physicians should be prepared to act appropriately in the prevention of cardiovascular risk factors. However, the rates of patients with control of blood pressure (BP) remain low. The impact of the reclassification of high BP by 24-hour ambulatory BP monitoring (ABPM) can lead to different medical decisions in PHC. OBJECTIVE: : To evaluate the agreement between the BP measured by a conventional method by PHC physicians and by 24-hour ABPM, considering different BP normal thresholds for the 24-hour ABPM according to the V Brazilian ABPM Guidelines and the European Society of Hypertension Guidelines. METHODS: : A cross-sectional study including 569 hypertensive patients. The BP was initially measured by the PHC physicians and, later, by 24-hour ABPM. The BP measurements were obtained independently between the two methods. The therapeutic targets for the conventional BP followed the guidelines by the Eighth Joint National Committee (JNC 8), the V ABPM Brazilian Guidelines, and the 2013 European Hypertension Guidelines. RESULTS: : There was an accuracy of 54.8% (95% confidence interval [95%CI] 0.51 - 0.58%) for the BP measured with the conventional method when compared with the 24-hour ABPM, with a sensitivity of 85% (95%CI 80.8 - 88.6%), specificity of 31.9% (95%CI 28.7 - 34.7%), and kappa value of 0.155, when considering the European Hypertension Guidelines. When using more stringent thresholds to characterize the BP as "normal" by ABPM, the accuracy was 45% (95%CI 0.41 - 0.47%) for conventional measurement when compared with 24-hour ABPM, with a sensitivity of 86.7% (95%CI 0.81 - 0.91%), specificity of 29% (95%CI 0.26 - 0.30%), and kappa value of 0.103. CONCLUSION: : The BP measurements obtained by PHC physicians showed low accuracy when compared with those obtained by 24-hour ABPM, regardless of the threshold set by the different guidelines. FUNDAMENTOS:: A hipertensão arterial sistêmica é um fator de risco importante para desfechos cardiovasculares. Médicos da atenção primária à saúde (APS) devem estar preparados para atuar adequadamente na prevenção de fatores de risco cardiovascular. No entanto, as taxas de pacientes com pressão arterial (PA) controlada continuam baixas. O impacto da reclassificação do diagnóstico de hipertensão pela utilização da monitorização ambulatorial da PA (MAPA) de 24 horas pode levar a diferentes decisões médicas na APS. OBJETIVO:: Avaliar a concordância entre as PAs medidas por método convencional por médicos da APS e por MAPA de 24 horas, considerando diferentes limiares de normalidade para a MAPA de 24 horas de acordo com as recomendações da V Diretriz Brasileira de MAPA e da Diretriz da Sociedade Europeia de Hipertensão. MÉTODOS:: Estudo transversal com 569 pacientes hipertensos. A PA foi medida inicialmente por médicos da APS e, posteriormente, pela MAPA de 24 horas. As medidas foram obtidas de forma independente entre os dois métodos. Os alvos terapêuticos para a PA convencional seguiram as orientações do Eighth Joint National Committee (JNC 8), das V Diretrizes Brasileiras de MAPA e das Diretrizes Europeias de Hipertensão de 2013. RESULTADOS:: Foi observada uma acurácia de 54,8% (intervalo de confiança de 95% [IC95%] 0,51 - 0,58%) para a PA aferida de forma convencional quando comparada à obtida com a MAPA de 24 horas, além de uma sensibilidade de 85% (IC95% 80,8 - 88,6%), especificidade de 31,9% (IC95% 28,7 - 34,7%) e kappa de 0,155, quando consideradas as Diretrizes Europeias de Hipertensão. Quando utilizados limiares mais rígidos para caracterizar a PA como "normal" pela MAPA, foi identificada uma acurácia de 45% (IC95% 0,41 - 0,47%) pela medida convencional quando comparada à obtida pela MAPA de 24 horas, além de uma sensibilidade de 86,7% (IC95% 0,81 - 0,91%), especificidade de 29% (IC95% 0,26 - 0,30%) e kappa de 0,103. CONCLUSÃO:: As medidas de PA avaliadas pelos médicos da APS apresentaram baixa acurácia quando comparadas às medidas pela MAPA de 24 horas, independente do limiar utilizado pelas diferentes diretrizes.
Hypertension, a chronic disease with an estimated prevalence of 40-45% in adults, is
a recognized public health problem and the main cause of general
mortality,[1] for which low
rates of control still remain.[2] The
hypertensive patient requires periodic medical care associated with adequate
pharmacological therapy and lifelong lifestyle changes.[3] The contribution of 24-hour blood pressure (BP)
assessment by ambulatory BP monitoring (ABPM) in the diagnosis, monitoring, and
prognostic stratification of hypertension is clearly defined in the
literature.[4]A national study compared the BP classification according to new thresholds
established by the VI Brazilian Guideline for Hypertension / V Brazilian Guideline
for ABPM, in relation to those previously established by the IV Brazilian Guideline
for ABPM.[5] The authors observed
that the new thresholds substantially reclassified hypertension, increasing the
percentage of hypertensive patients, especially for the variable systolic BP during
sleep.[5] When considering
different thresholds for 24-hour borderline BP / hypertension and normal BP /
borderline BP, and the reclassification of hypertensive patients in regard to their
control, it was observed that the samples of patients in the studies were similar in
regard to antihypertensive treatment. Regarding the IDACO study, [6] the guidelines from the European
Society of Cardiology (ESC) have maintained BP thresholds for the definition of
hypertension by 24-hour ABPM as values greater than or equal to 130 mmHg for
systolic BP and 80 mmHg for diastolic BP.[7]Two questions of application in clinical practice regarding the care of the
hypertensive patient remain little explored: the applicability and the importance of
more rigorous thresholds as criteria of normality for BP, and the prospective
evaluation of the diagnostic accuracy between the different methods of BP
measurement.[8] These
inquiries arise from a need for prospective studies and elaboration of databases,
preferably national ones, to allow a more adequate assessment of the ABPM normality
thresholds for the hypertensive population, especially those attended by the primary
health care (PHC) system.This study proposed to evaluate the diagnostic accuracy of BP measurement by the
conventional method, performed by PHC physicians, and the agreement of these
measures with those obtained by the 24-hour ABPM, set as normality thresholds by the
guidelines.
Methods
Delineation and participants
The participants of this cross-sectional study conducted at two health posts
included hypertensive patients from Antônio Prado (RS), a city in the
south of Brazil with 12,883 inhabitants.[9] All patients were hypertensive, were enrolled in the
Programa de Saúde da Família (Family
Health Program, PSF), took part in regular clinical follow-up at the
hypertension outpatient clinic of the city's two Unidades
Básicas de Saúde (Basic Health Units, UBS),
and were on antihypertensive treatment for at least 6 months.The samples were randomly selected from the total set of hypertensive patients
enrolled in the UBSs, through random numbers generated by the program Microsoft
Excel 2010. Patients were assessed by their own PHC physicians during routine
visits to the hypertension outpatient clinic from January 2013 to October 2014.
Patients who had participated in a previous cross-sectional study,[8] which included an assessment
with 24-hour ABPM, were contacted by phone and/or letter to participate in this
new study. Those who were not able to answer the questionnaire, pregnant women,
individuals with a non-sinus rhythm electrocardiogram, residents from outside
the coverage area of the UBSs, patients who switched cities or who were not
found, and those who did not tolerate the use of ABPM or who presented some
technical difficulty in the application of the method were excluded. Thus, out
of the total of 639 patients, 28 were excluded from the study due to
complications related to technical problems in the reading and failures in the
adjustment of the ABPM cuff (18 patients), sleep disorders that prevented
adequate BP measurements (8 patients), and intolerance of the equipment due to
anxiety (2 patients).All subjects agreed to participate in the study and signed an informed consent
form. The results of the biochemical tests and ABPM performed during the study
were delivered to the patients. The project was approved by the Research Ethics
Committee (REC) of the IC/FUC - 4278.08.
Measurements performed
The BP was verified by the PHC physicians through three measurements with a
mercury sphygmomanometer (the use of a mercury column sphygmomanometer is
allowed in the state of Rio Grande do Sul, which follows the guidelines of the
Resolution of the Collegiate Board of Directors no. 63, dated November 25, 2011,
article 23) with orientation for individualized adjustment of the cuff, with the
patients in a seated position and their feet resting on the floor and after a
minimum rest period of 5 minutes. The physicians at the health centers were
instructed to measure the BP in both arms, taking, as a reference, the highest
value obtained after an approximate interval of 3 minutes between measurements.
The first measurement was discarded, and the mean of the two subsequent
measurements was calculated and recorded on the patient's chart. Then, during
the same visit, the patient was referred to a nurse trained for this study who
placed the device for the 24-hour ABPM, applied a standardized questionnaire,
and obtained the anthropometric measurements. Subsequently, the patient's
medical records were reviewed, biochemical exams were requested, and the ABPM
report was prepared blindly by the investigating physician. The ABPM device was
applied during a normal day of the patient's work activity, excluding days on
the weekends and holidays. Based on prognostic evidence, the ABPM was selected
as the standard reference for BP measurements and for assessing the diagnostic
accuracy of the conventional BP measurement.[10]The ABPM monitors used in the study were duly validated and calibrated according
to international recommendations.[11] The ABPM recorder used was the DMS Brasil model TM 2430 and
the model of the mercury sphygmomanometer was the MDF 800. The ABPM was
scheduled to record a BP measurement every 15 minutes during the waking period
and every 30 minutes during sleep. The schedules were adjusted according to the
individualization of the sleep and awakening habits of each patient. The
obtaining of data from at least 60 records in the 24-hour period was considered
adequate, with at least two records every hour during the sleep period. The
parameters assessed by the ABPM were the mean systolic and diastolic BP from the
24-hour, waking, and nocturnal periods. For the conventional measurements,
uncontrolled hypertension was defined as the achievement of values ≥
140/90 mmHg, according to the main hypertension guidelines. For the group of
patients aged ≥ 60 years, guidelines from the Eighth Joint National
Committee (JNC 8) were also adopted.[1]
Parameters and classification
In order to classify hypertension as uncontrolled, the ABPM criteria of the
European Hypertension Guidelines and the Brazilian Hypertension Guidelines from
the Brazilian Society of Cardiology were adopted.[12,13]
Thus, patients with a mean BP of ≥ 130/80 mmHg in 24 hours,
≥ 135/85 mmHg in the waking period and ≥ 120/70 mmHg for
the nocturnal mean BP for the first criterion were considered as having
uncontrolled hypertension.[12]
Whereas, when the guidelines of the Brazilian Guidelines for Hypertension were
observed,[13] the values
for BP used in the study were the borderline ones considered normal as cutoff
point for the 24-hour averages: >125/75 mmHg, > 130/85 mmHg for the waking
period, and > 110/70 mmHg for the mean BP during sleep.[14]A ≤ 10% reduction in the mean nocturnal BP in relation to the daytime
mean in the ABPM was defined as an absence of nocturnal descent.[3] The white coat syndrome (WCS)
was considered to be present when a patient on antihypertensive treatment had
high BP, as measured in the clinic environment and/or under surveillance, but
controlled BP in other situations.[15] Masked hypertension (MH) was characterized by the presence
of a BP that was controlled when obtained with a conventional measurement, but
high when obtained with ABPM or in-home measurements.[16] "Masking effect" was the term used when MH was
observed in hypertensive patients using antihypertensive treatment. The same
values for the normality criteria for 24-hour BP were considered for diabetic
and nondiabetic patients.
Laboratory evaluation
In addition to BP measurements by the conventional method and the 24-hour ABPM,
the biochemical profile of the patients in this study was evaluated. Laboratory
tests included total cholesterol, LDL-cholesterol, HDL-cholesterol,
triglycerides, creatinine, blood count, glycosylated hemoglobin (fraction A1c),
microalbuminuria, and fasting blood glucose. Anthropometric data, such as body
mass, height, waist-hip ratio, and body mass index were also evaluated. The
screening questionnaire also included validated instruments for the evaluation
of smoking and nicotine dependence (Fagerström test), abusive alcohol
consumption (Alcohol Use Disorders Identification Test, AUDIT), and adherence to
treatment using the Morisky Medication Adherence Scale.[8]
Statistical methods
Data entry and analysis were performed using the SPSS statistical software,
version 21.0. Descriptive statistics were performed with continuous variables
(mean and standard deviation) and categorical variables (frequency
distribution). The estimated sample size was 398 patients and was based on the
previous cross-sectional study conducted at the same site of the current study
and on BP control rates of 55% for ABPM and 41% for conventional measurements
performed by the PHC physicians for a confidence interval of 95% (95%CI) and 80%
power. The sample was considered representative of the PHC service in the city
of Antônio Prado (RS) because it was randomly selected at the two
health posts with hypertension outpatient clinics, out of a total of 1,216
patients enrolled in this system. The hypertension care units, where the study
was conducted, are referential units of the PHC in the city.The comparison between the subgroups was performed using the chi-square test,
Mann-Whitney U test (for continuous variables with non-homogeneous variances),
and Student's t test (for variables with homogeneous
variances). To analyze the agreement between the techniques of BP evaluation,
kappa statistics was used. A multivariate analysis was also performed for
cardiovascular risk factors and agreement of BP control, according to the
24-hour ABPM compared with conventional BP. P values < 0.05 were considered
significant.
Results
Between January 2013 and October 2014, a consecutive sample of 639 hypertensive
patients enrolled in the hypertension outpatient clinic of two health posts in the
city of Antônio Prado (RS) was selected from a total of 1,216 patients.
ABPM was applied in 611 patients who remained in the study after application of the
exclusion criteria, shortly after conventional BP measurements by PHC physicians.
The final sample comprised 569 patients after exclusion of patients who abandoned
the research protocol or who presented inadequate ABPM measurements. No patient
required medical care due to the compressive action of the ABPM cuff, whose reported
events included: local discomfort (22 patients), mild local erythema (6 patients),
and short-term paresthesia in the limb used for placing the cuff (2 patients). Table 1 summarizes the demographic profile and
lifestyle of the patients.
Table 1
Demographic profile and lifestyle of the patients in the sample
Total (n = 569)*
- Female n (%)
339 (59.6%)
- Age (years)
60.32 +/- 13.58 (20-89)
- White
504 (88.1%)
- BMI **
28.54 +/- 4.57 (19-46)
- Fasting blood glucose (mg/dL)
100 +/- 26.89 (47-279)
- Glycosylated hemoglobin
6.14 +/- 4.52 (2.7–11.2)
- Total cholesterol (mg/dL)
203.9 +/- 40.28 (88-453)
- HDL-cholesterol (mg/dL)
52.73 +/- 12.51 (39.1-66.2)
- LDL-cholesterol (mg/dL)
121.36 +/- 33.78 (14-241)
- Triglycerides (mg/dL)
155.98 +/- 136.55 (35-2446)
- Creatinine (mg/dL)
0.88 +/- 0.27 (0.41-3.09)
- Smoking n (%)
32 (5.6%)
- Alcohol consumption n (%) (> 30 g/day)
174 (30.6%)
- Microalbuminuria > 30 mg/dL n (%)
151 (26.4%)
- Physical activity n (%)
276 (48.5%)
- Physical activity > 150 min/week n (%)
148 (53.6%)
Standard deviation, percentage and maximum and minimum values;
body mass index (kg/m2).
Demographic profile and lifestyle of the patients in the sampleStandard deviation, percentage and maximum and minimum values;body mass index (kg/m2).In relation to BP measured by the conventional method versus 24-hour
ABPM, we observed an accuracy of 54.8% (95%CI 0.51 - 0.58%) and, when considering
the European Society of Hypertension Guidelines, a sensitivity of 85% (95%CI 80.8 -
88.6%), a specificity of 31.9% (95%CI 28.7 - 34.7%), and a kappa value of 0.155.
When more stringent thresholds were used to characterize BP as "normal" by ABPM, we
identified an accuracy of 45% (95%CI 0.41 - 0.47%) by the conventional measurement
when compared with 24-hour ABPM, in addition to a sensitivity of 86.7% (95%CI 0.81 -
0.91%), a specificity of 29% (95%CI 0.26 - 0.30%), and a kappa value of 0.103 (Table 2).
Table 2
General accuracy for conventional measurement of blood pressure (BP)
according to the various normality thresholds for 24-hour ambulatory blood
pressure monitoring (ABPM) *
Accuracy
Sensitivity
Specificity
95%C
kappa
ABPM 130/80 mmHg*X BP Conventional Method
54.8%
85%
31.9%
0.513-0.580
0.155
ABPM 125/75 mmHg X BP Conventional
Method
45%
86.7%
29%
0.418 – 0.475
0.103
ABPM 130/80 mmHg*X BP JNC 8**
51.8%
88.5%
23.8%
0.485 – 0.546
0.111
ABPM 125/75 mmHg X BP JNC 8**
40.6%
89.8%
21.6%
0.377 – 0.428
0.072
ESC 2013 and Joint 8
SBP normal ≤ 150 mmHg. 95%CI: 95% confidence interval; JNC 8:
Eighth Joint National Committee.
General accuracy for conventional measurement of blood pressure (BP)
according to the various normality thresholds for 24-hour ambulatory blood
pressure monitoring (ABPM) *ESC 2013 and Joint 8SBP normal ≤ 150 mmHg. 95%CI: 95% confidence interval; JNC 8:
Eighth Joint National Committee.The prevalence of WCS and the masking effect in treated hypertensive patients was
3.1% and 46.9%, respectively, when considering the European Hypertension Guidelines
for ABPM. On the other hand, the prevalence of WCS and MH was 2% and 56.1%,
respectively, according to the different cutoff criteria for ABPM normality. When we
considered the JNC 8 recommendations for conventional measurements, the prevalence
of WCS and MH presented a slight variation. The prevalences according to the various
parameters of ABPM and conventional measurement is shown in Table 3.
Table 3
White coat effect and masked hypertension according to the parameters of
24-hour ambulatory blood pressure monitoring (ABPM) and conventional
measurement of blood pressure (BP)*
White Coat Effect
Masked
ABPM 130/80 mmHg*X BP Conventional Method
6.5% (37)
38.7% (220)
ABPM 125/75 mmHg X BP Conventional
Method
3.7% (21)
51.3% (292)
ABPM 130/80 mmHg *X BP JNC 8**
5% (28)
43.3% (244)
ABPM 125/75 mmHg X BP JNC 8**
2.8% (16)
56.6% (319)
ESC 2013 e Joint 8
PAS normal ≤ 150 mmHg. JNC 8: Eighth Joint National
Committee.
White coat effect and masked hypertension according to the parameters of
24-hour ambulatory blood pressure monitoring (ABPM) and conventional
measurement of blood pressure (BP)*ESC 2013 e Joint 8PAS normal ≤ 150 mmHg. JNC 8: Eighth Joint National
Committee.
Discussion
The present study, including hypertensive patients receiving PHC, showed differences
in accuracy and agreement between BP measurements performed by PHC physicians
according to the different parameters of normality for 24-hour ABPM, as determined
by the European Hypertension Guidelines and by the V Brazilian Guidelines for ABPM,
respectively. The main result was the low accuracy of the conventional measures when
compared with those obtained by the 24-hour ABPM, regardless of the guideline or
cutoff point adopted for normal 24-hour ABPM. Regarding the differences in normality
thresholds for 24-hour ABPM, when more stringent BP control targets were used, the
accuracy of conventional measurements was even lower.The vast majority of hypertensive patients are assisted by the PHC system,[17] in which physicians play a
relevant role in the search for better results in BP control. In addition, the use
of auxiliary methods for BP measurements to assess the adequacy of antihypertensive
treatment has not been widely adopted in PHC.[15] In a national study using ABPM, a high degree of
reproducibility was observed between casual measurements performed by non-medical
professionals and those performed in an environment with a high standard of
standardization in BP measurement.[18] However, although casual BP measure is still the standard for
hypertension diagnosis and control, its adoption with the rigor of controlled
studies is not a reality in the current clinical practice of PHC. Additionally, the
24-hour BP assessment is the reference standard for prognostic evaluation, reduction
of false diagnoses, and BP control evaluations.In another national study with a retrospective analysis of ABPM
examinations,[5] the impact
of the reclassification of BP control thresholds was evaluated according to the
application of the last two Brazilian ABPM Guidelines. With the adoption of the
current guidelines, all modified thresholds reclassified the exams significantly.
The present study, however, sought to prospectively assess the impact of adopting
different thresholds of normality for ABPM in comparison with measures performed by
PHC physicians. The results, in terms of accuracy, were similar to those of other
studies that indicated a low accuracy of BP obtained by conventional measures
compared with that obtained by ABPM,[8] but with unique results when comparing different guidelines for
24-hour mean pressure thresholds.Current guidelines for hypertension recommend satisfactory BP control for
cardiovascular protection in both primary and secondary prevention.[19] The extent of agreement between
the classification of controlled and uncontrolled BP, based on conventional measures
and compared with 24-hour ABPM, is of strategic importance in PHC. The search for
normality thresholds for 24-hour ABPM is based on cardiovascular outcomes,[14] having the IDACO study database as
an example of a population benchmark. These results guided the normality targets for
ABPM in the different guidelines for hypertension. Thus, the adoption of normality
criteria for ABPM as a gold-standard auxiliary method for the control, evaluation
and prognostic stratification of hypertension[4] should ideally be supported by a database that reflects
population specificities.The Systolic Blood Pressure Intervention Trial (SPRINT) study[20] presents evidence of benefits for
BP control in hypertensive patients with stringent measures for systolic pressure
(< 120 mmHg) compared with a more flexible control (< 140 mmHg). Therefore,
evidence of reduced outcomes with more stringent cutoff points for BP control may
lead to substantial changes in future revisions of hypertension
guidelines.[20] Thus, this
need is in agreement with the evaluation of the impact on the diagnostic accuracy of
usual methods of BP in comparison with the different thresholds of normality for the
gold-standard BP evaluation.The adoption of the 24-hour ABPM through a single measurement in our sample may be
considered a limitation of the present study. This may imply a limitation in the
reproducibility of the measurements, especially when considering the evaluation of
the nocturnal decreasing BP pattern. However, to mitigate this potential limitation,
precautions were taken, such as the individualization of the sleep and waking
period, as well as a rigidity regarding the minimum number of measurements and the
quality of the measurements during the 24 hours as criteria for inclusion in the
study. These measurements followed the guidelines and recommendations of the Italian
Society of Hypertension.[21]The use of ABPM in PHC, as well as the impact of the reclassification of hypertension
according to the different normality thresholds for 24-hour BP, may have
implications for decision-making by PHC physicians. Thus, a more significant number
of national studies may serve as a reference for the elaboration of future
guidelines and indicate BP thresholds for therapeutic definition.
Conclusion
This study evaluated the use of 24-hour ABPM within the scope of the PHC. BP
measurements assessed by PHC physicians presented low accuracy when compared with
those obtained by 24-hour ABPM, regardless of the threshold used as a normality
criterion.
Authors: Larissa Rangel Nascimento; Maria del Carmen Bisi Molina; Carolina Perim Faria; Roberto de Sá Cunha; José Geraldo Mill Journal: Rev Saude Publica Date: 2013-06 Impact factor: 2.106
Authors: Décio Mion; Angela M G Pierin; Isabela M Bensenor; Júlio César M Marin; Karla Ryuko Abe Costa; Luiz Fernando de Oliveira Henrique; Natália de Pinho Alencar; Rodrigo do Carmo Couto; Tales Eduardo Laurenti; Thiago Arthur Oliveira Machado Journal: Arq Bras Cardiol Date: 2010-05-21 Impact factor: 2.000
Authors: Gustavo C Rodriguez-Roca; Francisco J Alonso-Moreno; Almudena Garcia-Jimenez; Alvaro Hidalgo-Vega; Jose L Llisterri-Caro; Vivencio Barrios-Alonso; Antonio Segura-Fragoso; Elvira Clemente-Lirola; Susana Estepa-Jorge; Yolanda Delgado-Cejudo; Jose M Lopez-Abuin Journal: Blood Press Date: 2006 Impact factor: 2.835
Authors: Giuseppe Mancia; Robert Fagard; Krzysztof Narkiewicz; Josep Redon; Alberto Zanchetti; Michael Böhm; Thierry Christiaens; Renata Cifkova; Guy De Backer; Anna Dominiczak; Maurizio Galderisi; Diederick E Grobbee; Tiny Jaarsma; Paulus Kirchhof; Sverre E Kjeldsen; Stéphane Laurent; Athanasios J Manolis; Peter M Nilsson; Luis Miguel Ruilope; Roland E Schmieder; Per Anton Sirnes; Peter Sleight; Margus Viigimaa; Bernard Waeber; Faiez Zannad; Josep Redon; Anna Dominiczak; Krzysztof Narkiewicz; Peter M Nilsson; Michel Burnier; Margus Viigimaa; Ettore Ambrosioni; Mark Caufield; Antonio Coca; Michael Hecht Olsen; Roland E Schmieder; Costas Tsioufis; Philippe van de Borne; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J Bax; Héctor Bueno; Veronica Dean; Christi Deaton; Cetin Erol; Robert Fagard; Roberto Ferrari; David Hasdai; Arno W Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Patrizio Lancellotti; Ales Linhart; Petros Nihoyannopoulos; Massimo F Piepoli; Piotr Ponikowski; Per Anton Sirnes; Juan Luis Tamargo; Michal Tendera; Adam Torbicki; William Wijns; Stephan Windecker; Denis L Clement; Antonio Coca; Thierry C Gillebert; Michal Tendera; Enrico Agabiti Rosei; Ettore Ambrosioni; Stefan D Anker; Johann Bauersachs; Jana Brguljan Hitij; Mark Caulfield; Marc De Buyzere; Sabina De Geest; Geneviève Anne Derumeaux; Serap Erdine; Csaba Farsang; Christian Funck-Brentano; Vjekoslav Gerc; Giuseppe Germano; Stephan Gielen; Herman Haller; Arno W Hoes; Jens Jordan; Thomas Kahan; Michel Komajda; Dragan Lovic; Heiko Mahrholdt; Michael Hecht Olsen; Jan Ostergren; Gianfranco Parati; Joep Perk; Jorge Polonia; Bogdan A Popescu; Zeljko Reiner; Lars Rydén; Yuriy Sirenko; Alice Stanton; Harry Struijker-Boudier; Costas Tsioufis; Philippe van de Borne; Charalambos Vlachopoulos; Massimo Volpe; David A Wood Journal: Eur Heart J Date: 2013-06-14 Impact factor: 29.983