Screw penetration of the hip joint following acetabular fracture reconstruction is a relatively uncommon complication but, if not corrected, may have a catastrophic effect on the postoperative function of the hip joint. Intraoperative radiographs and postoperative standard anteroposterior (AP) radiographs frequently show super-imposition of the screws and acetabulum. Computed tomographic (CT) scanning has been the only diagnostic technique available allowing documentation of screw penetration into the hip joint. CT scan, however, can be performed only after termination of surgery. In search for a radiological view that will help in diagnosing screw penetration into the hip joint both intra- and postoperatively, we undertook a controlled study of 25 patients having either a posterior or extensile lateral surgical approach and six cadaveric specimens. A combination of a cross-table lateral view of the hip and a Judet iliac view proved more informative than AP or Judet obturator views in demonstrating absence or presence of the screw in the hip joint (if the screws were placed along the posterior wall or column). Intraoperative AP radiographs projected as a Judet obturator view were the least helpful in making this determination. When screw penetration is suspected, we recommend the use of intraoperative fluoroscopy in multiple projections or intraoperative arthrogram in the lateral projection of the pelvis. Also, Judet iliac and cross-table lateral radiographs in the operating room while the patient is still under anesthesia might exclude any screw penetration into the hip joint.

Entities:  

Mesh:

Year:  1989        PMID: 2809819     DOI: 10.1097/00005131-198909000-00003

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  8 in total

1.  Biomechanical comparison of methods of fixation of isolated osteotomies of the posterior acetabular column.

Authors:  A Schopfer; D DiAngelo; T Hearn; J Powell; M Tile
Journal:  Int Orthop       Date:  1994-04       Impact factor: 3.075

2.  A safe technique of anterior column lag screw fixation in acetabular fractures.

Authors:  Ramesh Kumar Sen; Sujit Kumar Tripathy; Sameer Aggarwal; Tarun Goyal; Dharm S Meena; Santosh Mahapatra
Journal:  Int Orthop       Date:  2012-09-23       Impact factor: 3.075

3.  The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans.

Authors:  Chun Bi; Jiandong Wang; Xiaoxi Ji; Zhijian Ma; Fang Wang; Xiangsen Zeng; Dongmei Wang; Qiugen Wang
Journal:  BMC Musculoskelet Disord       Date:  2017-02-20       Impact factor: 2.362

4.  Acetabular Lateral View: Effective Fluoroscopic Imaging to Evaluate Screw Penetration Intraoperatively.

Authors:  Zhe Lin; Jialiang Guo; Weichong Dong; Kuo Zhao; Zhiyong Hou; Yingze Zhang
Journal:  Med Sci Monit       Date:  2019-08-10

5.  Digital anatomical study and clinical application of screw placement for quadrilateral plate fractures in the danger zone.

Authors:  Bei Zhao; Zhongye Sun; Wei Zhang; Zhongbao Xu; Xiaofei Yang; Weidong Mu
Journal:  BMC Musculoskelet Disord       Date:  2020-04-11       Impact factor: 2.362

6.  Fluoroscopic views for safe insertion of lag screws into the posterior column of the acetabulum.

Authors:  Wei Chen; Zekun Zhang; Yang Lu; Jia Li; Yingze Zhang; Yong Shen
Journal:  BMC Musculoskelet Disord       Date:  2014-09-15       Impact factor: 2.362

7.  Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

Authors:  Ke Su; Song Liu; Tao Wu; Yingchao Yin; Ruipeng Zhang; Shilun Li; Yingze Zhang
Journal:  PLoS One       Date:  2017-11-20       Impact factor: 3.240

8.  Which radiograph is most accurate for assessing hip joint penetration in infra-acetabular screw placement?

Authors:  Eic Ju Lim; Seungyeob Sakong; Wonseok Choi; Jong-Keon Oh; Jae-Woo Cho
Journal:  Medicine (Baltimore)       Date:  2021-06-18       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.