Assessing nitrous oxide effect using electroencephalographically-based depth of anesthesia measures cortical state and cortical input.

Levin Kuhlmann1,2, David T J Liley3.   

Abstract

Existing electroencephalography (EEG) based depth of anesthesia monitors cannot reliably track sedative or anesthetic states during n-methyl-D-aspartate (NMDA) receptor antagonist based anesthesia with ketamine or nitrous oxide (N2O). Here, a physiologically-motivated depth of anesthesia monitoring algorithm based on autoregressive-moving-average (ARMA) modeling and derivative measures of interest, Cortical State (CS) and Cortical Input (CI), is retrospectively applied in an exploratory manner to the NMDA receptor antagonist N2O, an adjuvant anesthetic gas used in clinical practice. Composite Cortical State (CCS) and Composite Cortical State distance (CCSd), two new modifications of CS, along with CS and CI were evaluated on electroencephalographic (EEG) data of healthy control individuals undergoing N2O inhalation up to equilibrated peak gas concentrations of 20, 40 or 60% N2O/O2. In particular, CCSd has been devised to vary consistently for increasing levels of anesthetic concentration independent of the anesthetic's microscopic mode of action for both N2O and propofol. The strongest effects were observed for the 60% peak gas concentration group. For the 50-60% peak gas levels, individuals showed statistically significant reductions in responsiveness compared to rest, and across the group CS and CCS increased by 39 and 42%, respectively, while CCSd was found to decrease by 398%. On the other hand a clear conclusion regarding the changes in CI could not be reached. These results indicate that, contrary to previous depth of anesthesia monitoring measures, the CS, CCS, and especially CCSd measures derived from frontal EEG are potentially useful for differentiating gas concentration and responsiveness levels in people under N2O. On the other hand, determining the utility of CI in this regard will require larger sample sizes and potentially higher gas concentrations. Future work will assess the sensitivity of CS-based and CI measures to other anesthetics and their utility in a clinical environment.

Entities:  

Keywords:  Anesthesia; Autoregressive moving-average modelling; Electroencephalography; Nitrous oxide; Sedation

Mesh:

Substances:

Year:  2017        PMID: 28097611     DOI: 10.1007/s10877-017-9978-1

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  43 in total

1.  Frequency band of EMG in anaesthesia monitoring.

Authors:  K Kamata; A J Aho; S Hagihira; A Yli-Hankala; V Jäntti
Journal:  Br J Anaesth       Date:  2011-11       Impact factor: 9.166

Review 2.  Nitrous oxide: are we still in equipoise? A qualitative review of current controversies.

Authors:  K de Vasconcellos; J R Sneyd
Journal:  Br J Anaesth       Date:  2013-06-25       Impact factor: 9.166

Review 3.  Nitrous oxide: a unique drug of continuing importance for anaesthesia.

Authors:  Philip M Hopkins
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2005-09

4.  Prevention of intraoperative awareness with explicit recall in an unselected surgical population: a randomized comparative effectiveness trial.

Authors:  George A Mashour; Amy Shanks; Kevin K Tremper; Sachin Kheterpal; Christopher R Turner; Satya Krishna Ramachandran; Paul Picton; Christa Schueller; Michelle Morris; John C Vandervest; Nan Lin; Michael S Avidan
Journal:  Anesthesiology       Date:  2012-10       Impact factor: 7.892

5.  Nitrous oxide-induced slow and delta oscillations.

Authors:  Kara J Pavone; Oluwaseun Akeju; Aaron L Sampson; Kelly Ling; Patrick L Purdon; Emery N Brown
Journal:  Clin Neurophysiol       Date:  2015-06-10       Impact factor: 3.708

6.  Drug-induced modification of the system properties associated with spontaneous human electroencephalographic activity.

Authors:  David T J Liley; Peter J Cadusch; Marcus Gray; Pradeep J Nathan
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2003-11-24

Review 7.  Bispectral index for improving anaesthetic delivery and postoperative recovery.

Authors:  Yodying Punjasawadwong; Aram Phongchiewboon; Nutchanart Bunchungmongkol
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

8.  Effects of nitrous oxide sedation on resting electroencephalogram topography.

Authors:  Brett L Foster; David T J Liley
Journal:  Clin Neurophysiol       Date:  2012-09-08       Impact factor: 3.708

9.  Dissociating the effects of nitrous oxide on brain electrical activity using fixed order time series modeling.

Authors:  David T J Liley; Kate Leslie; Nicholas C Sinclair; Martin Feckie
Journal:  Comput Biol Med       Date:  2008-10-02       Impact factor: 4.589

10.  Disruption of frontal-parietal communication by ketamine, propofol, and sevoflurane.

Authors:  UnCheol Lee; SeungWoo Ku; GyuJeong Noh; SeungHye Baek; ByungMoon Choi; George A Mashour
Journal:  Anesthesiology       Date:  2013-06       Impact factor: 7.892

View more
  3 in total

1.  Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers.

Authors:  Andria Pelentritou; Levin Kuhlmann; John Cormack; Will Woods; Jamie Sleigh; David Liley
Journal:  J Vis Exp       Date:  2018-01-13       Impact factor: 1.355

2.  Paradox of age: older patients receive higher age-adjusted minimum alveolar concentration fractions of volatile anaesthetics yet display higher bispectral index values.

Authors:  Katherine Ni; Mary Cooter; Dhanesh K Gupta; Jake Thomas; Thomas J Hopkins; Timothy E Miller; Michael L James; Miklos D Kertai; Miles Berger
Journal:  Br J Anaesth       Date:  2019-07-03       Impact factor: 9.166

Review 3.  Molecular Diversity of Anesthetic Actions Is Evident in Electroencephalogram Effects in Humans and Animals.

Authors:  Sarah Eagleman; M Bruce MacIver
Journal:  Int J Mol Sci       Date:  2021-01-06       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.