Literature DB >> 28097422

Novel alignment measurement technique for total knee arthroplasty using patient specific instrumentation.

Kazumasa Yamamura1, Yukihide Minoda2, Shigekazu Mizokawa1, Yoichi Ohta1, Ryo Sugama1, Suguru Nakamura1, Hideki Ueyama1, Hiroaki Nakamura1.   

Abstract

INTRODUCTION: This study was designed to evaluate the true accuracy of patient specific instrumentation (PSI) for total knee arthroplasty (TKA) using a new 3D measurement method.
MATERIALS AND METHODS: Consecutive 21 patients (30 knees) who underwent TKA using computed tomography (CT)-based PSI were retrospectively evaluated. Mean patient age was 69.2 years (62 to 77). The postoperative three-dimensional (3D) CT image were superimposed onto the preoperative 3D CT plan and measured the absolute difference in the prosthetic alignment using six parameters: coronal, sagittal, and axial alignment of the femoral and tibial prostheses. Cases in which the difference in the prosthetic alignment was greater than 3° were considered outliers.
RESULTS: For the femoral prosthesis, mean absolute differences between the preoperative 3D CT plan and postoperative 3D CT image were not significantly different and the rates of outliers were 10.0, 33.3, 23.3% in the coronal, sagittal, and axial planes. For the tibial prosthesis, mean absolute differences were significantly larger in the axial plane than in the coronal and sagittal planes (p < 0.001) and the rates of outliers were 23.3, 36.7, 63.3% in the coronal, sagittal, and axial planes. The rates of outliers for the axial alignment of tibial prosthesis were significantly higher than for the other five planes (p = 0.006).
CONCLUSIONS: The rotation of the tibial prosthesis with CT-based PSI was less accurate in the axial plane than in the other five planes.

Entities:  

Keywords:  Computed tomography; Patient specific instrumentation; Three-dimensional evaluation; Total knee arthroplasty

Mesh:

Year:  2017        PMID: 28097422     DOI: 10.1007/s00402-017-2628-8

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  6 in total

1.  Design improvement in patient-specific instrumentation for total knee arthroplasty improved the accuracy of the tibial prosthetic alignment in the coronal and axial planes.

Authors:  Kazumasa Yamamura; Yukihide Minoda; Ryo Sugama; Yoichi Ohta; Suguru Nakamura; Hideki Ueyama; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-25       Impact factor: 4.342

2.  Evaluation of the accuracy of resected bone thickness based on patient-specific instrumentation during total knee arthroplasty.

Authors:  Kazumasa Yamamura; Fumiaki Inori; Sadahiko Konishi
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-06       Impact factor: 3.067

3.  Conventional instruments are more accurate for measuring the depth of the tibial cut than computer-assisted surgery in total knee arthroplasty: a prospective study.

Authors:  Antonio Klasan; Sven Edward Putnis; Samuel Grasso; Thomas Neri; Myles Raphael Coolican
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-07       Impact factor: 3.067

4.  Accuracy of tibial positioning in the frontal plane: a prospective study comparing conventional and innovative techniques in total knee arthroplasty.

Authors:  R K Zahn; F Graef; J L Conrad; L Renner; C Perka; H Hommel
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-02       Impact factor: 3.067

5.  Primary total knee arthroplasty assisted by computed tomography-free navigation for secondary knee osteoarthritis following massive calcium phosphate cement packing for distal femoral giant-cell bone tumor treatment: a case report.

Authors:  Akihiko Takeuchi; Norio Yamamoto; Takaaki Ohmori; Katsuhiro Hayashi; Shinji Miwa; Kentaro Igarashi; Takashi Higuchi; Kensaku Abe; Hirotaka Yonezawa; Sei Morinaga; Yoshihiro Araki; Yohei Asano; Shiro Saito; Hiroyuki Tsuchiya
Journal:  BMC Musculoskelet Disord       Date:  2022-02-22       Impact factor: 2.362

6.  Measurement for gap balancing technique in patients undergoing total knee arthroplasty: a large retrospective observational study.

Authors:  Zhao Xuequan; Zhao Bin; Yao Shuzhang; Cao Kanduo; Ren Chongxi
Journal:  J Orthop Surg Res       Date:  2022-04-07       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.