Literature DB >> 28095522

Correlation Between Resonance Frequency Analysis and Bone Quality Assessments at Dental Implant Recipient Sites.

Min-Wen Fu, Earl Fu, Fu-Gong Lin, Wei-Jeng Chang, Yao-Dung Hsieh, E-Chin Shen.   

Abstract

PURPOSE: To evaluate whether primary implant stability could be used to predict bone quality, the association between the implant stability quotient (ISQ) value and the bone type at the implant site was evaluated.
MATERIALS AND METHODS: Ninety-five implant sites in 50 patients were included. Bone type (categorized by Lekholm and Zarb) at the implant site was initially assessed using presurgical dental radiography. During the preparation of the implant site, a bone core specimen was carefully obtained. The bone type was assessed by tactile sensation during the drilling operation, according to the Misch criteria. The primary stability of the inserted implant was evaluated by resonance frequency analysis (RFA). The ISQ value was recorded. The bone core specimen was then examined by stereomicroscopy or microcomputed tomography (micro-CT), and the bone type was determined by the surface characteristics of the specimen, based on Lekholm and Zarb classification. Agreement between the bone quality assessed by the four methods (ie, presurgical radiography, tactile sensation, stereomicroscopy, and micro-CT) was tested by Cohen's kappa statistics, whereas the association between the ISQ value and the bone type was evaluated by the generalized linear regression model.
RESULTS: The mean ISQ score was 72.6, and the score was significantly influenced by the maxillary or mandibular arch (P = .001). The bone type at the implant sites varied according to the assessment method. However, a significant influence of the arch was repeatedly noted when using radiography or tactile sensation. Among the four bone-quality assessment methods, a weak agreement existed only between stereomicroscopy and micro-CT, especially in the maxilla (κ = 0.469). A negative association between the ISQ value and the bone type assessed by stereomicroscopy or by micro-CT was significant in the maxilla, but not in the mandible, after adjustments for sex, age, and right/left side (P = .013 and P = .027 for stereomicroscopy and micro-CT, respectively).
CONCLUSION: The ISQ value was weakly associated with the bone type when assessed by stereomicroscopy or micro-CT in the maxilla. Caution is necessary if RFA is used as a tool to evaluate bone quality at the implant site, especially in the mandible.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28095522     DOI: 10.11607/jomi.4684

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  Computer-based automatic classification of trabecular bone pattern can assist radiographic bone quality assessment at dental implant site.

Authors:  Laura Ferreira Pinheiro Nicolielo; Jeroen Van Dessel; G Harry van Lenthe; Ivo Lambrichts; Reinhilde Jacobs
Journal:  Br J Radiol       Date:  2018-09-17       Impact factor: 3.039

2.  Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study.

Authors:  Ramón Silva; Pablo Villalón; Felipe Cáceres
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-29

3.  Effects of photofunctionalization on early osseointegration of titanium dental implants in the maxillary posterior region: a randomized double-blinded clinical trial.

Authors:  Bada Choi; Ye Chan Lee; Kyung Chul Oh; Jae Hoon Lee
Journal:  Int J Implant Dent       Date:  2021-05-10

4.  Effect of the lack of primary stability in the survival of dental implants.

Authors:  Carlos Cobo-Vázquez; David Reininger; Pedro Molinero-Mourelle; José González-Serrano; Blanca Guisado-Moya; Juan López-Quiles
Journal:  J Clin Exp Dent       Date:  2018-01-01

5.  Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.

Authors:  Fernanda Faot; Amália Machado Bielemann; Alessandra Julie Schuster; Raissa Micaella Marcello-Machado; Altair Antoninha Del Bel Cury; Gustavo G Nascimento; Otacílio Luiz Chagas-Junior
Journal:  Biomed Res Int       Date:  2019-06-02       Impact factor: 3.411

6.  Repeatability of the resonance frequency analysis values in implants with a new technology.

Authors:  M-C Díaz-Castro; A Falcao; P López-Jarana; C Falcao; J-V Ríos-Santos; A Fernández-Palacín; M Herrero-Climent
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2019-09-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.