Literature DB >> 28088750

Continuous minimally-invasive alcohol monitoring using microneedle sensor arrays.

A M Vinu Mohan1, Joshua Ray Windmiller2, Rupesh K Mishra1, Joseph Wang3.   

Abstract

The present work describes an attractive skin-worn microneedle sensing device for the minimally invasive electrochemical monitoring of subcutaneous alcohol. The device consists of an assembly of pyramidal microneedle structures integrated with Pt and Ag wires, each with a microcavity opening. The microneedle aperture was modified by electropolymerizing o-phenylene diamine onto the Pt wire microtransducer, followed by the immobilization of alcohol oxidase (AOx) in an intermediate chitosan layer, along with an outer Nafion layer. The resulting microneedle-based enzyme electrode displays an interference-free ethanol detection in artificial interstitial fluid without compromising its sensitivity, stability and response time. The skin penetration ability and the efficaciousness of the biosensor performance towards subcutaneous alcohol monitoring was substantiated by the ex vivo mice skin model analysis. Our results reveal that the new microneedle sensor holds considerable promise for continuous non-invasive alcohol monitoring in real-life situations.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alcohol; Biosensor; Microneedle; Minimally-invasive monitoring; Wearable sensor

Mesh:

Substances:

Year:  2017        PMID: 28088750      PMCID: PMC5323319          DOI: 10.1016/j.bios.2017.01.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  24 in total

1.  Transdermal alcohol measurement for estimation of blood alcohol concentration.

Authors:  R Swift
Journal:  Alcohol Clin Exp Res       Date:  2000-04       Impact factor: 3.455

2.  Breath alcohol measurement variability associated with different instrumentation and protocols.

Authors:  Rod G Gullberg
Journal:  Forensic Sci Int       Date:  2003-01-09       Impact factor: 2.395

3.  Studies on a wearable, electronic, transdermal alcohol sensor.

Authors:  R M Swift; C S Martin; L Swette; A LaConti; N Kackley
Journal:  Alcohol Clin Exp Res       Date:  1992-08       Impact factor: 3.455

Review 4.  Microneedles for transdermal drug delivery.

Authors:  Mark R Prausnitz
Journal:  Adv Drug Deliv Rev       Date:  2004-03-27       Impact factor: 15.470

5.  A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat.

Authors:  M Gamella; S Campuzano; J Manso; G González de Rivera; F López-Colino; A J Reviejo; J M Pingarrón
Journal:  Anal Chim Acta       Date:  2013-09-16       Impact factor: 6.558

6.  Biochemical analysis of wound fluid from nonhealing and healing chronic leg ulcers.

Authors:  N J Trengove; S R Langton; M C Stacey
Journal:  Wound Repair Regen       Date:  1996 Apr-Jun       Impact factor: 3.617

7.  Accuracy and precision of breath-alcohol measurements for a random subject in the postabsorptive state.

Authors:  G Simpson
Journal:  Clin Chem       Date:  1987-02       Impact factor: 8.327

8.  Synthetic interstitial fluid for isolated mammalian tissue.

Authors:  A H Bretag
Journal:  Life Sci       Date:  1969-03-01       Impact factor: 5.037

Review 9.  Urine as a biological specimen for forensic analysis of alcohol and variability in the urine-to-blood relationship.

Authors:  Alan W Jones
Journal:  Toxicol Rev       Date:  2006

10.  Alcohol consumption, alcohol-related problems, problem drinking, and socioeconomic status.

Authors:  J A van Oers; I M Bongers; L A van de Goor; H F Garretsen
Journal:  Alcohol Alcohol       Date:  1999 Jan-Feb       Impact factor: 2.826

View more
  34 in total

1.  Wearable Bioelectronics: Enzyme-Based Body-Worn Electronic Devices.

Authors:  Jayoung Kim; Itthipon Jeerapan; Juliane R Sempionatto; Abbas Barfidokht; Rupesh K Mishra; Alan S Campbell; Lee J Hubble; Joseph Wang
Journal:  Acc Chem Res       Date:  2018-11-06       Impact factor: 22.384

2.  Wearable Electrochemical Alcohol Biosensors.

Authors:  Alan S Campbell; Jayoung Kim; Joseph Wang
Journal:  Curr Opin Electrochem       Date:  2018-05-23

Review 3.  Microneedles for transdermal diagnostics: Recent advances and new horizons.

Authors:  Gui-Shi Liu; Yifei Kong; Yensheng Wang; Yunhan Luo; Xudong Fan; Xi Xie; Bo-Ru Yang; Mei X Wu
Journal:  Biomaterials       Date:  2019-12-26       Impact factor: 12.479

4.  A randomized controlled non-inferiority trial of primary care-based facilitated access to an alcohol reduction website (EFAR Spain).

Authors:  Elsa Caballeria; Hugo López-Pelayo; Lidia Segura; Paul Wallace; Clara Oliveras; Estela Díaz; Jakob Manthey; Begoña Baena; Joan Colom; Antoni Gual
Journal:  Internet Interv       Date:  2021-08-20

5.  Using machine learning for real-time BAC estimation from a new-generation transdermal biosensor in the laboratory.

Authors:  Catharine E Fairbairn; Dahyeon Kang; Nigel Bosch
Journal:  Drug Alcohol Depend       Date:  2020-08-01       Impact factor: 4.492

Review 6.  Mobile alcohol biosensors and pharmacotherapy development research.

Authors:  Walter Roberts; Sherry A McKee
Journal:  Alcohol       Date:  2018-08-03       Impact factor: 2.405

7.  Hollow Prussian Blue nanocubes as peroxidase mimetic and enzyme carriers for colorimetric determination of ethanol.

Authors:  Shuangling Wang; Han Yan; Yalin Wang; Na Wang; Yulong Lin; Meng Li
Journal:  Mikrochim Acta       Date:  2019-11-01       Impact factor: 5.833

8.  Fluorescence Sensing Behavior for the Detection of Alcoholic Strength and Water Based on Two Novel Metallic Complex Edifices.

Authors:  Dong Lu; Yiping Tang; Yuhui Zheng
Journal:  J Fluoresc       Date:  2018-09-17       Impact factor: 2.217

Review 9.  Recent advances on microneedle arrays-mediated technology in cancer diagnosis and therapy.

Authors:  Vahid Alimardani; Samira Sadat Abolmaali; Ali Mohammad Tamaddon; Mohammad Ashfaq
Journal:  Drug Deliv Transl Res       Date:  2021-06       Impact factor: 4.617

Review 10.  Microneedle-based devices for point-of-care infectious disease diagnostics.

Authors:  Rachael V Dixon; Eldhose Skaria; Wing Man Lau; Philip Manning; Mark A Birch-Machin; S Moein Moghimi; Keng Wooi Ng
Journal:  Acta Pharm Sin B       Date:  2021-02-16       Impact factor: 11.413

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.