Literature DB >> 28074591

Variations in crestal cortical bone thickness at dental implant sites in different regions of the jawbone.

Yi-Chun Ko1, Heng-Li Huang1,2, Yen-Wen Shen1,3, Jyun-Yi Cai1,3, Lih-Jyh Fuh1,3, Jui-Ting Hsu1,2.   

Abstract

BACKGROUND: Dental implants have become reliable and predictable tools for treating missing teeth. The survival rate of dental implants is markedly influenced by the host bone quality and quantity of the jawbone. A better host bone provides higher initial stability of the dental implant, resulting in better osseointegration and a higher success rate. Host bone quality and quantity are determined by the crestal cortical bone thickness and inner cancellous bone density.
OBJECTIVE: The purpose of this study was to determine the crestal cortical bone thickness at dental implant sites in different regions of the jawbone through the use of dental cone-beam computed tomographic (CBCT) images.
MATERIALS AND METHODS: A total of 661 dental implant sites (81 in the anterior mandible, 122 in the anterior maxilla, 224 in the posterior mandible, and 234 in the posterior maxilla) were obtained from the jawbones of 173 humans. The data were subjected to statistical analysis to determine any correlation between crestal cortical bone thicknesses and jawbone regions using one-way analysis of variance with Tukey's post-test.
RESULTS: The crestal cortical bone thicknesses at dental implant sites in the four regions decreased in the following order: posterior mandible (1.07 ± 0.47 mm, mean ± SD) >anterior mandible (0.99 ± 0.36 mm) >anterior maxilla (0.82 ± 0.30 mm) >posterior maxilla (0.75 ± 0.35 mm).
CONCLUSION: The dental CBCT data demonstrate that crestal cortical bone thickness varies markedly between dental implant sites in the four regions of the jawbone.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  cortical bone thickness; dental cone-beam computed tomography; dental implant site; jawbone

Mesh:

Substances:

Year:  2017        PMID: 28074591     DOI: 10.1111/cid.12468

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  16 in total

1.  Radiological implications of crestal and subcrestal implant placement in posterior areas. A cone-beam computed tomography study.

Authors:  Hilario Pellicer-Chover; Julio Rojo-Sanchís; Miguel Peñarrocha-Diago; José Viña-Almunia; David Peñarrocha-Oltra; Maria Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2020-09-01

2.  The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey.

Authors:  Yaser Safi; Reza Amid; Fariba Zadbin; Mitra Ghazizadeh Ahsaie; Hamed Mortazavi
Journal:  Imaging Sci Dent       Date:  2021-05-06

3.  Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT.

Authors:  Norliza Ibrahim; Azin Parsa; Bassam Hassan; Paul van der Stelt; Rabiah A Rahmat; Siti M Ismail; Irene H A Aartman
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

4.  Retrospective cohort study of rough-surface titanium implants with at least 25 years' function.

Authors:  Tadashi Horikawa; Tetsurou Odatsu; Takatoshi Itoh; Yoshiki Soejima; Hutoshi Morinaga; Naruyoshi Abe; Naoyuki Tsuchiya; Toshikazu Iijima; Takashi Sawase
Journal:  Int J Implant Dent       Date:  2017-09-05

5.  Influence of different restorative materials on the stress distribution in dental implants.

Authors:  Carlos-Eduardo Datte; João-Paulo-Mendes Tribst; Amanda-Maria-de Oliveira Dal Piva; Renato-Sussumu Nishioka; Marco-Antonio Bottino; Alexandre-Duarte M Evangelhista; Fabrício M de M Monteiro; Alexandre-Luiz-Souto Borges
Journal:  J Clin Exp Dent       Date:  2018-05-01

6.  Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Danieli Moura Brasil; Daniela Verardi Madlum; Francisco Haiter-Neto; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-06-18

7.  Improving the prediction of the trabecular bone microarchitectural parameters using dental cone-beam computed tomography.

Authors:  Rong-Ting He; Ming-Gene Tu; Heng-Li Huang; Ming-Tzu Tsai; Jay Wu; Jui-Ting Hsu
Journal:  BMC Med Imaging       Date:  2019-01-23       Impact factor: 1.930

8.  Analysis of Alveolar Bone Morphology of the Maxillary Central and Lateral Incisors with Normal Occlusion.

Authors:  Ji-Eun Lee; Chang Yoon Jung; Yoonji Kim; Yoon-Ah Kook; Youngkyung Ko; Jun-Beom Park
Journal:  Medicina (Kaunas)       Date:  2019-09-03       Impact factor: 2.430

9.  Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks.

Authors:  Francesco Orlando; Federico Arosio; Paolo Arosio; Danilo Alessio Di Stefano
Journal:  Dent J (Basel)       Date:  2019-07-01

10.  Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study.

Authors:  Vincenzo Bruno; Cesare Berti; Carlo Barausse; Mauro Badino; Roberta Gasparro; Daniela Rita Ippolito; Pietro Felice
Journal:  Biomed Res Int       Date:  2018-05-31       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.