Literature DB >> 28068823

Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

Bariq Al-Amiry1,2, Sarwar Mahmood2, Ferid Krupic3, Arkan Sayed-Noor2.   

Abstract

Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

Entities:  

Keywords:  Hip arthroplasty; femoral offset; leg length discrepancy; plain radiographs; reliability

Mesh:

Year:  2017        PMID: 28068823     DOI: 10.1177/0284185116684676

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  7 in total

1.  Highlights of the annual scientific meeting of the 24th congress of the European Society of Musculoskeletal Radiology (ESSR) 2017.

Authors:  Carmelo Messina; Luca Maria Sconfienza; Giuseppe Guglielmi
Journal:  Skeletal Radiol       Date:  2017-09-20       Impact factor: 2.199

2.  Influence of implantation of a total hip endoprosthesis on the ipsilateral leg alignment: the effect of sex and dysplasia of the hip.

Authors:  Stefan van Drongelen; Benjamin Fey; Felix Stief; Andrea Meurer
Journal:  Arch Orthop Trauma Surg       Date:  2022-08-24       Impact factor: 2.928

Review 3.  Narrative Review of the Mechanism of Hip Prosthesis Dislocation and Methods to Reduce the Risk of Dislocation.

Authors:  Maciej Kostewicz; Grzegorz Szczęsny; Wiesław Tomaszewski; Paweł Małdyk
Journal:  Med Sci Monit       Date:  2022-06-18

4.  Effectiveness of a patient-specific guide for femoral stem implantation in primary total hip arthroplasty: a randomized control trial.

Authors:  Xin Jin; Mengcun Chen; Adnan N Cheema; Xianzhe Liu; Shuhua Yang; Weihua Xu
Journal:  Int Orthop       Date:  2022-01-28       Impact factor: 3.479

5.  Discrepancy of Trial Rasp and Femoral Stem Relative Position Within the Femoral Canal of a Coated Tapered System: An Intraoperative, Intrapatient Controlled Study.

Authors:  Thomas Hofstaedter; Michael Najfeld; Gion Fessel; Luca C Orlandini; Robert Hube
Journal:  Arthroplast Today       Date:  2020-09-25

6.  Plain radiography findings to predict dislocation after total hip arthroplasty.

Authors:  Qing Liu; Xiaoguang Cheng; Dong Yan; Yixin Zhou
Journal:  J Orthop Translat       Date:  2019-01-06       Impact factor: 5.191

7.  Restoring global offset and lower limb length with a 3 offset option double-tapered stem.

Authors:  Stefano Biggi; Lorenzo Banci; Riccardo Tedino; Andrea Capuzzo; Gabriele Cattaneo; Stefano Tornago; Andrea Camera
Journal:  BMC Musculoskelet Disord       Date:  2020-10-02       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.